Specialist Fibre Optic Buffer Tube Opening Kits
Accessing optical fibres inside a buffer tube requires controlled cutting. If the tube is opened using an unsuitable tool or excessive blade depth, the fibres beneath can be damaged, turning a planned connection or maintenance task into a more involved repair.
Rennsteig Master Set In Cases at Industrial Shed includes two specialist fibre-optic cable opening kits: the RAUCUT I Master Set In Case & RAUCUT II Master Set In Case.
These are purpose-designed buffer tube opening systems, not general electrical crimping kits, mechanical master tool sets or fibre-optic fusion splicers.
For compatible smaller buffer tube applications, explore Rennsteig Cable Guides for RAUCUT I interchangeable guides. For other specialist cable preparation equipment, see Rennsteig Insulation Stripper & Blades, noting that conventional electrical insulation strippers do not replace fibre-optic buffer tube opening tools.
The key selection decision is the buffer tube diameter & the method required to open it without damaging the fibres.
What Are Rennsteig Master Set In Cases?
The master sets in this collection are cased RAUCUT tools used to open fibre-optic buffer tubes.
Fibre-optic cables may contain optical fibres within protective tubes. During installation, branching or repair work, technicians sometimes need to access those fibres without unnecessarily cutting through the entire tube.
The two systems address different tube sizes & use different guide components.
► RAUCUT I: Designed for opening cut or uncut mini-buffer tubes, using interchangeable tube guides.
► RAUCUT II: Designed for opening larger uncut buffer tubes, using guide rollers & an adjustable cutting arrangement.
► Application-specific accessories: Each set contains components associated with its particular RAUCUT system.
► Protective case: Keeps the tool & included accessories together for transport & workshop storage.
► Serviceable components: Rennsteig identifies replacement cutting components & guides for the corresponding systems.
The sets are not interchangeable simply because both are supplied in cases.
Why Choose Rennsteig Master Set In Cases?
Access Fibres Without Unnecessary Tube Separation
The RAUCUT systems are designed for opening compatible buffer tubes during fibre-optic cable preparation.
This can be useful where the installation procedure requires access to fibres within an existing tube.
Select a Tool for the Tube Diameter
RAUCUT I & RAUCUT II cover different buffer tube diameter ranges.
Choosing the correct system helps avoid attempting a procedure with unsuitable guiding geometry.
Keep Accessories Together
The supplied case provides a dedicated place for the tool & its associated guides, rollers or service accessories.
Support Planned Fibre Maintenance
A correctly configured buffer tube opening tool can be part of a controlled fibre access or branching procedure.
Maintain the System With Specified Components
Rennsteig lists replacement guides, rollers & blades for the relevant RAUCUT systems.
These parts must be matched to the exact tool model.
Common Applications
Fibre-Optic Cable Access
Technicians may need to expose fibres inside a compatible buffer tube during installation or maintenance.
Mid-Span Fibre Access
Where permitted by the cable design & work procedure, an uncut buffer tube may need opening at a selected location.
Telecommunications Network Maintenance
Specialist fibre technicians may use the correct RAUCUT system during approved network rework or cable servicing.
Fibre Distribution & Branching Work
Buffer tube access can be necessary when preparing fibres for a planned branch or connection.
Fibre-Optic Workshop Preparation
Workshops can configure the appropriate RAUCUT tool before carrying out cable preparation on a known tube construction.
For other connector-related workshop tasks, Rennsteig Assembly Tools covers separate electrical contact insertion & removal applications.
Product Selection Guide
Compare RAUCUT I & RAUCUT II
|
Feature
|
RAUCUT I
|
RAUCUT II
|
|
Industrial Shed SKU
|
800710706AF
|
800730306AF
|
|
Manufacturer reference
|
8007 1070 6
|
8007 3030 6
|
|
Primary application
|
Mini-buffer tube opening
|
Larger buffer tube opening
|
|
Documented tube diameter range
|
0.9–4.2 mm
|
4–14 mm
|
|
Guiding system
|
Interchangeable tube guides
|
Interchangeable guide rollers
|
|
Supplied case
|
Yes
|
Yes
|
|
Manufacturer-listed weight
|
940 g
|
2,900 g
|
The AF-suffixed retail references should be confirmed against the corresponding manufacturer products before ordering.
RAUCUT I – For Mini-Buffer Tubes
The RAUCUT I is designed to open cut or uncut mini-buffer tubes while reducing the risk of damage to the enclosed optical fibres when used correctly.
The manufacturer lists the following included tube guides:
► 1.8 mm
► 2.0 mm
► 2.4 mm
► 2.8 mm
► 3.0 mm
► 3.5 mm
► 4.2 mm
The manufacturer's case specification also lists a spatula, Allen key & replacement blade.
Additional guide sizes are available separately.
RAUCUT II – For Larger Buffer Tubes
The RAUCUT II is intended for opening larger uncut buffer tubes.
Rennsteig documents an adjustable cutting arrangement with guide rollers for compatible tube diameters.
The manufacturer lists six included guide rollers:
► 5 mm
► 6 mm
► 7 mm
► 8 mm
► 9 mm
► 10 mm
The case specification also identifies a knob, Allen key, screwdriver & spatula.
Other roller sizes are available separately for compatible applications.
Step 1: Identify the Buffer Tube
Measure the actual outside diameter of the tube being opened.
Do not select the tool using the overall cable diameter.
Step 2: Check the Tube Construction
Confirm the cable manufacturer's permitted opening method.
Different tube materials & fibre arrangements may require different procedures.
Step 3: Select the Appropriate RAUCUT System
Use RAUCUT I for compatible mini-buffer tubes within its specified range.
Use RAUCUT II for larger compatible buffer tubes within its documented range.
Step 4: Confirm Included Accessories
Check whether the guide or roller size required for the job is included in the case.
A tool's full operating range does not mean every available guide is supplied.
Step 5: Plan the Fibre Handling Procedure
Opening a buffer tube is only one stage of fibre preparation.
Follow the applicable cleaning, fibre handling, protection & testing requirements.
Expert Tips
Measure the Tube Before Choosing a Guide
Select the guide or roller for the actual buffer tube diameter.
Avoid Excessive Cutting Depth
Follow the manufacturer's adjustment procedure to minimise the risk of fibre damage.
Inspect the Tool Before Use
Check the cutting edge, guide components & adjustment mechanism for damage or contamination.
Keep Guides & Rollers Identified
Store components with their sizes visible to reduce changeover errors.
For additional workshop organisation, explore Tool Storage.
Use Appropriate Fibre Safety Procedures
Handle fibre shards as sharps, use suitable eye protection & follow the workplace's fibre-disposal procedure.
Never look into an optical fibre without confirming that it is safe to do so.
Verify the Opening Method
Do not assume every fibre cable can be opened mid-span.
Check the cable manufacturer's instructions & the approved network work method.
Maintain Cutting Components
Replace damaged or worn parts using the correct manufacturer reference.