► Red Cat | Grommets

Wiring & Blanking Grommets for Panel Openings A drilled hole can look harmless until a cable starts moving against its edge. Red Cat grommets protect wiring where cables, looms or suitable hoses pass through compatible metal panels, cabinets, vehicle bodies & equipment enclosures. The range also includes blanking grommets for...

Wiring & Blanking Grommets for Panel Openings

A drilled hole can look harmless until a cable starts moving against its edge. Red Cat grommets protect wiring where cables, looms or suitable hoses pass through compatible metal panels, cabinets, vehicle bodies & equipment enclosures. The range also includes blanking grommets for closing unused panel openings where nothing needs to pass through.

Choosing the right grommet comes down to fit. Check the panel-hole size, panel thickness &, for wiring grommets, the outside diameter of the cable or loom.  Measuring & Layout Tools can help with accurate positioning & measurement before drilling, while  Cable Ties & Clips can support the cable route beyond the penetration.

A grommet that fits the cable but does not seat correctly in the panel is still the wrong grommet.

What Are Red Cat Grommets?

Red Cat grommets are flexible inserts fitted into openings in panels, cabinets & fabricated equipment.

The collection covers two different jobs.

Wiring grommets sit around a panel opening where a cable or wiring loom passes through. They provide a protective interface between the cable insulation & the cut or drilled edge of the panel.

Blanking grommets close an opening that is no longer required or has been provided for future use.

The distinction is simple but important. If something needs to pass through the panel, look at wiring grommets. If the opening needs to be closed, look at blanking grommets.

The current Red Cat range includes wiring grommets across several internal diameters plus EPDM blanking grommets in multiple sizes.

Why Choose Red Cat Grommets?

A small panel penetration can become a wear point when equipment is exposed to vibration, movement or regular use.

Where wiring passes directly through sheet metal, repeated contact with an unfinished or unprotected edge can damage the cable insulation. A correctly selected wiring grommet separates the cable from that edge while allowing it to pass through the panel.

Blanking grommets address another common workshop problem. Removed accessories, changed wiring routes & unused provisions can leave open holes in vehicle bodies, cabinets or fabricated panels. A compatible blanking grommet provides a straightforward way to close the opening.

Neither type should be selected on appearance alone. The panel opening, retaining profile & relevant dimensions need to suit one another if the grommet is to remain properly seated.

Common Applications

Ute Canopies & Service Vehicles

Accessory wiring often needs to pass between compartments or through panels inside a service body.

Plan the route before drilling. Avoid placing the opening unnecessarily close to a folded edge, hinge, latch or structural section, then select the grommet around the finished panel opening & cable dimensions.

Also consider what happens when nearby doors, drawers or equipment move. The loom should not be stretched or trapped during normal operation.

Trailer Wiring

Trailer lighting, auxiliary power & accessory circuits can require wiring to pass through steel or aluminium sections.

A wiring grommet protects the cable at the penetration, but the rest of the loom still needs an appropriate route & adequate support.

Pay particular attention around tailgates, ramps or other moving components. Leave enough cable movement for normal operation without allowing the loom to rub continuously against surrounding hardware.

Electrical Cabinets & Enclosures

Cable penetrations in cabinets should be planned around the wiring route rather than placed wherever space happens to remain.

Check the panel opening, material thickness & cable diameter before selecting the grommet.

Where the installation also requires mechanical cable retention, strain relief or a specified environmental seal, use hardware designed for those functions. A standard wiring grommet should not automatically be treated as a cable gland.

Machinery & Workshop Equipment

Fabricated guards, housings & equipment panels commonly require wiring to pass between sections.

Watch the direction in which the cable approaches the grommet. If the loom is pulling hard against one side, improve the routing or add suitable support rather than expecting the grommet to restrain the cable.

Hand Tools provides related equipment for general panel preparation, fitting & workshop work.

Unused Panel Holes

Not every grommet carries wiring.

Red Cat blanking grommets can be used to close compatible unused openings in panels, vehicle bodies, cabinets & fabricated equipment.

This is particularly useful when an accessory has been removed or a pre-existing penetration is no longer required.

Fabrication & Equipment Builds

New fabrication gives you the opportunity to choose the grommet before making the final opening.

Establish the cable route, identify the required grommet dimensions then cut or drill the panel to suit. This is preferable to making an arbitrary hole first & trying to find a grommet that happens to fit afterwards.

Where new openings are required, Drill Bit Sets provides related workshop tooling.

Product Selection Guide

Start with the panel, then the cable. Three measurements deserve particular attention: panel-hole size, panel thickness & cable or loom diameter.

Decide What the Opening Needs to Do

Choose a wiring grommet when a cable, loom or suitable hose needs to pass through the panel.

Choose a blanking grommet when the opening needs to be closed.

Similar outside dimensions do not make the two types interchangeable.

Measure the Panel Opening

Measure the actual hole rather than estimating it from the component previously fitted.

If the opening has not yet been made, check the intended grommet dimensions first. Once a hole has been cut too large, your options become considerably more limited.

For an existing opening, also inspect whether it is genuinely round & undamaged before relying on a single diameter measurement.

Measure the Cable or Loom

For wiring grommets, measure the outside diameter of whatever needs to pass through the centre.

The current Red Cat wiring range includes several internal-diameter options. Select against the actual cable or loom rather than judging the opening visually.

Avoid forcing an oversized cable through a substantially smaller centre opening. Excessive stretching can distort how the grommet sits in the panel.

Check Panel Thickness

Panel thickness affects how the grommet engages with the edge of the opening.

Two panels can have identical hole diameters but different material thicknesses, so the same grommet should not automatically be assumed suitable for both.

Check the relevant product dimensions against the actual panel.

Read the Dimensions in Context

Grommet listings can contain several different measurements.

Depending on the product, these may include:

► Internal diameter
► Panel-hole size
► Outside diameter
► Groove dimensions
► Overall dimensions

Confirm what each measurement represents before drilling or ordering. The largest number shown is not necessarily the required panel-hole diameter.

Prepare the Opening

Inspect a new opening before fitting the grommet.

Remove burrs & deal with irregular edges appropriately for the panel material. A rough opening can make the grommet difficult to seat & creates an unnecessary source of wear.

If replacing a failed grommet, check the existing hole for damage before fitting the new part.

Route & Support the Cable

Once the cable has passed through the grommet, consider where it goes next.

Avoid leaving the loom under tension or pulling continually against one side of the opening. Use suitable cable management where support or routing is required.

The grommet protects the penetration. It should not be expected to carry the weight of an unsupported loom.

Separate Edge Protection From Sealing

A wiring grommet & a sealed cable entry do not necessarily perform the same job.

If the installation requires a defined ingress rating, environmental seal or dedicated strain relief, check the requirements separately & use components specifically suited to them.

Do not assume those properties simply because the grommet is made from a flexible material.

Inspect the Finished Fit

Check both sides of the panel where possible.

The grommet should sit evenly around the opening without a section of its retaining profile folded over, pulled through or sitting outside the panel.

Move the cable gently through its normal range. The grommet should remain seated without the loom placing excessive side load on it.

Expert Tips

Replacing a grommet takes very little time. Working out why the old one failed is often more useful.

► Measure the hole & cable separately. They are different dimensions with different roles in the fit.
► Choose the grommet before drilling where possible. It gives you control over the final panel opening.
► Inspect the cable when an old grommet is damaged. Abrasion may already have started on the insulation.
► Check the panel edge. A replacement grommet fitted into a damaged or badly finished opening may develop the same problem.
► Support heavier looms independently. Do not make the grommet carry cable weight it was not intended to support.
► Look for sideways pull. A cable continually loading one side of the grommet usually needs its route reconsidered.
► Check both faces of the panel. A grommet can look correctly installed from one side while its retaining edge is not properly seated on the other.
► Measure old accessory holes rather than guessing. Previous modifications do not always follow standard nominal dimensions.
► Do not confuse protection with sealing. Where water, dust or other ingress requirements matter, confirm the appropriate hardware for that application.
► Recheck moving assemblies. A loom that looks fine with a door closed may tighten considerably when that door reaches its fully open position.

Why Buy From Industrial Shed?

Industrial Shed's Red Cat Grommets collection covers two practical panel requirements: protecting wiring at compatible penetrations & closing openings that are no longer being used.

The range includes wiring grommets across several internal diameters plus EPDM blanking grommets in multiple sizes. Clear measurements matter here. Identifying the opening, panel thickness & cable dimensions before ordering can make installation considerably more straightforward.

For a look inside the type of working environment where vehicle wiring, body hardware & workshop equipment come together, read A Day With An Automotive Mechanic Peninsula.

Equipment that works through vibration, weather & repeated use also benefits from regular inspection. Spring Jobsite Prep Getting Your Gear Ready covers broader checks before equipment returns to heavier use.

Once you have confirmed the grommet type & dimensions required, Same day dispatch provides current shipping & delivery information.

For businesses managing ongoing workshop, fleet or fabrication requirements, on -site & workshop Services provides further Industrial Shed support.

Measure First, Then Make the Opening

✔ Decide between wiring & blanking grommets
✔ Measure the panel opening accurately
✔ Check the panel thickness
✔ Measure the cable or loom independently
✔ Confirm what each listed grommet dimension represents
✔ Prepare & deburr newly created openings
✔ Support the cable beyond the penetration
✔ Inspect both sides of the installed grommet

A grommet costs very little compared with the wiring it protects. Get the opening right, support the cable properly & check the finished fit before the equipment goes back into service.

Frequently Asked Questions

What is the difference between a wiring grommet & a blanking grommet?

A wiring grommet provides a centre opening for a cable or loom. A blanking grommet closes an unused panel opening.

How do I choose the correct wiring grommet size?

Check the panel-hole diameter, panel thickness & outside diameter of the cable or loom. All three measurements can affect whether the grommet is suitable.

Should I choose the grommet before drilling the panel?

Where possible, yes. Confirming the required grommet dimensions first allows the panel opening to be made to suit rather than trying to match a grommet to an arbitrary hole afterwards.

Does a wiring grommet provide strain relief?

A standard wiring grommet should not automatically be treated as strain relief. Its primary role is protecting the cable at the panel opening. Use appropriate cable support where mechanical restraint is required.

Are Red Cat grommets waterproof?

Do not assume a waterproof or ingress rating unless the individual product specification confirms one. Applications requiring a rated seal should use hardware specifically suited to that requirement.

What should I inspect when replacing a damaged grommet?

Check the panel edge, opening dimensions, cable insulation & cable route. Identifying abrasion, excessive movement or poor fit before replacement can help prevent the same problem occurring again.

Brands

► Red Cat | Grommets

Wiring & Blanking Grommets for Panel Openings

A drilled hole can look harmless until a cable starts moving against its edge. Red Cat grommets protect wiring where cables, looms or suitable hoses pass through compatible metal panels, cabinets, vehicle bodies & equipment enclosures. The range also includes blanking grommets for closing unused panel openings where nothing needs to pass through.

Choosing the right grommet comes down to fit. Check the panel-hole size, panel thickness &, for wiring grommets, the outside diameter of the cable or loom.  Measuring & Layout Tools can help with accurate positioning & measurement before drilling, while  Cable Ties & Clips can support the cable route beyond the penetration.

A grommet that fits the cable but does not seat correctly in the panel is still the wrong grommet.

What Are Red Cat Grommets?

Red Cat grommets are flexible inserts fitted into openings in panels, cabinets & fabricated equipment.

The collection covers two different jobs.

Wiring grommets sit around a panel opening where a cable or wiring loom passes through. They provide a protective interface between the cable insulation & the cut or drilled edge of the panel.

Blanking grommets close an opening that is no longer required or has been provided for future use.

The distinction is simple but important. If something needs to pass through the panel, look at wiring grommets. If the opening needs to be closed, look at blanking grommets.

The current Red Cat range includes wiring grommets across several internal diameters plus EPDM blanking grommets in multiple sizes.

Why Choose Red Cat Grommets?

A small panel penetration can become a wear point when equipment is exposed to vibration, movement or regular use.

Where wiring passes directly through sheet metal, repeated contact with an unfinished or unprotected edge can damage the cable insulation. A correctly selected wiring grommet separates the cable from that edge while allowing it to pass through the panel.

Blanking grommets address another common workshop problem. Removed accessories, changed wiring routes & unused provisions can leave open holes in vehicle bodies, cabinets or fabricated panels. A compatible blanking grommet provides a straightforward way to close the opening.

Neither type should be selected on appearance alone. The panel opening, retaining profile & relevant dimensions need to suit one another if the grommet is to remain properly seated.

Common Applications

Ute Canopies & Service Vehicles

Accessory wiring often needs to pass between compartments or through panels inside a service body.

Plan the route before drilling. Avoid placing the opening unnecessarily close to a folded edge, hinge, latch or structural section, then select the grommet around the finished panel opening & cable dimensions.

Also consider what happens when nearby doors, drawers or equipment move. The loom should not be stretched or trapped during normal operation.

Trailer Wiring

Trailer lighting, auxiliary power & accessory circuits can require wiring to pass through steel or aluminium sections.

A wiring grommet protects the cable at the penetration, but the rest of the loom still needs an appropriate route & adequate support.

Pay particular attention around tailgates, ramps or other moving components. Leave enough cable movement for normal operation without allowing the loom to rub continuously against surrounding hardware.

Electrical Cabinets & Enclosures

Cable penetrations in cabinets should be planned around the wiring route rather than placed wherever space happens to remain.

Check the panel opening, material thickness & cable diameter before selecting the grommet.

Where the installation also requires mechanical cable retention, strain relief or a specified environmental seal, use hardware designed for those functions. A standard wiring grommet should not automatically be treated as a cable gland.

Machinery & Workshop Equipment

Fabricated guards, housings & equipment panels commonly require wiring to pass between sections.

Watch the direction in which the cable approaches the grommet. If the loom is pulling hard against one side, improve the routing or add suitable support rather than expecting the grommet to restrain the cable.

Hand Tools provides related equipment for general panel preparation, fitting & workshop work.

Unused Panel Holes

Not every grommet carries wiring.

Red Cat blanking grommets can be used to close compatible unused openings in panels, vehicle bodies, cabinets & fabricated equipment.

This is particularly useful when an accessory has been removed or a pre-existing penetration is no longer required.

Fabrication & Equipment Builds

New fabrication gives you the opportunity to choose the grommet before making the final opening.

Establish the cable route, identify the required grommet dimensions then cut or drill the panel to suit. This is preferable to making an arbitrary hole first & trying to find a grommet that happens to fit afterwards.

Where new openings are required, Drill Bit Sets provides related workshop tooling.

Product Selection Guide

Start with the panel, then the cable. Three measurements deserve particular attention: panel-hole size, panel thickness & cable or loom diameter.

Decide What the Opening Needs to Do

Choose a wiring grommet when a cable, loom or suitable hose needs to pass through the panel.

Choose a blanking grommet when the opening needs to be closed.

Similar outside dimensions do not make the two types interchangeable.

Measure the Panel Opening

Measure the actual hole rather than estimating it from the component previously fitted.

If the opening has not yet been made, check the intended grommet dimensions first. Once a hole has been cut too large, your options become considerably more limited.

For an existing opening, also inspect whether it is genuinely round & undamaged before relying on a single diameter measurement.

Measure the Cable or Loom

For wiring grommets, measure the outside diameter of whatever needs to pass through the centre.

The current Red Cat wiring range includes several internal-diameter options. Select against the actual cable or loom rather than judging the opening visually.

Avoid forcing an oversized cable through a substantially smaller centre opening. Excessive stretching can distort how the grommet sits in the panel.

Check Panel Thickness

Panel thickness affects how the grommet engages with the edge of the opening.

Two panels can have identical hole diameters but different material thicknesses, so the same grommet should not automatically be assumed suitable for both.

Check the relevant product dimensions against the actual panel.

Read the Dimensions in Context

Grommet listings can contain several different measurements.

Depending on the product, these may include:

► Internal diameter
► Panel-hole size
► Outside diameter
► Groove dimensions
► Overall dimensions

Confirm what each measurement represents before drilling or ordering. The largest number shown is not necessarily the required panel-hole diameter.

Prepare the Opening

Inspect a new opening before fitting the grommet.

Remove burrs & deal with irregular edges appropriately for the panel material. A rough opening can make the grommet difficult to seat & creates an unnecessary source of wear.

If replacing a failed grommet, check the existing hole for damage before fitting the new part.

Route & Support the Cable

Once the cable has passed through the grommet, consider where it goes next.

Avoid leaving the loom under tension or pulling continually against one side of the opening. Use suitable cable management where support or routing is required.

The grommet protects the penetration. It should not be expected to carry the weight of an unsupported loom.

Separate Edge Protection From Sealing

A wiring grommet & a sealed cable entry do not necessarily perform the same job.

If the installation requires a defined ingress rating, environmental seal or dedicated strain relief, check the requirements separately & use components specifically suited to them.

Do not assume those properties simply because the grommet is made from a flexible material.

Inspect the Finished Fit

Check both sides of the panel where possible.

The grommet should sit evenly around the opening without a section of its retaining profile folded over, pulled through or sitting outside the panel.

Move the cable gently through its normal range. The grommet should remain seated without the loom placing excessive side load on it.

Expert Tips

Replacing a grommet takes very little time. Working out why the old one failed is often more useful.

► Measure the hole & cable separately. They are different dimensions with different roles in the fit.
► Choose the grommet before drilling where possible. It gives you control over the final panel opening.
► Inspect the cable when an old grommet is damaged. Abrasion may already have started on the insulation.
► Check the panel edge. A replacement grommet fitted into a damaged or badly finished opening may develop the same problem.
► Support heavier looms independently. Do not make the grommet carry cable weight it was not intended to support.
► Look for sideways pull. A cable continually loading one side of the grommet usually needs its route reconsidered.
► Check both faces of the panel. A grommet can look correctly installed from one side while its retaining edge is not properly seated on the other.
► Measure old accessory holes rather than guessing. Previous modifications do not always follow standard nominal dimensions.
► Do not confuse protection with sealing. Where water, dust or other ingress requirements matter, confirm the appropriate hardware for that application.
► Recheck moving assemblies. A loom that looks fine with a door closed may tighten considerably when that door reaches its fully open position.