500UM Polythene Damp Proof Course
Stopping rising moisture starts with putting the right barrier into the right building detail. Rally poly dampcourse is 500UM embossed polyethylene DPC for brickwork, blockwork, moisture-control details & concealed flashing applications. For surrounding project requirements, compare Waterproofing & Damp Proofing products alongside Weatherproofing Supplies when planning how different parts of the building envelope will manage moisture.
Rally polythene dampcourse combines a 0.5mm base thickness with an approximately 0.75mm embossed thickness. Rally also states conformance with AS 2904-1986, giving builders, bricklayers & contractors a clearly identified material specification across multiple widths.
Width should be established before roll length. Check the plans, wall detail, opening or concealed-flashing requirement first, then select the appropriate Rally width & calculate how much 30m or 50m material the project requires.
What Is Rally Poly Dampcourse?
Rally Poly Dampcourse is an embossed polyethylene moisture barrier used as damp proof course material & concealed flashing within building construction. It may also be described as polythene dampcourse, polyethylene dampcourse, plastic DPC or damp proof course.
Rally specifies:
► Embossed polyethylene construction
► 500UM or 0.5mm base thickness
► Approximately 0.75mm embossed thickness
► 30m & 50m roll options
► Multiple widths for different building details
► Damp-proof applications
► Concealed flashing applications
► Manufacturer-stated conformance with AS 2904-1986
The nominal 500UM specification refers to the base polyethylene thickness. Embossing increases the overall profile to approximately 0.75mm, so those figures shouldn't be treated as separate grades.
Why Choose Rally Polythene Dampcourse?
DPC is a small part of the finished wall but an important part of the moisture-control detail. Rally provides the same 500UM base material across multiple widths so buyers can select around the construction requirement instead of adapting one generic roll.
Practical range advantages include:
► Multiple DPC widths
► 30m & 50m roll options
► Embossed polyethylene construction
► 500UM base thickness
► Concealed flashing capability
► Rally-stated AS 2904-1986 conformance
► Product codes that help with repeat purchasing
Preparation becomes particularly important on larger builds using several widths. Recording the required dimension, roll length & product code helps prevent a generic “dampcourse” order arriving in a format that doesn't match the next stage of brickwork.
Common Applications
Brickwork & blockwork are among the clearest applications for polyethylene damp proof course. The material provides a physical moisture barrier where the building detail specifies compatible DPC or concealed flashing.
Relevant applications include:
► Damp proof course in brickwork
► Damp proof course in blockwork
► Internal wall moisture-control details
► Building details intended to restrict rising moisture
► Concealed window flashing
► Concealed door flashing
► New construction
► Renovation work requiring compatible concealed DPC
Placement should follow the actual building detail. Material selection doesn't replace the plans, specifications or installation requirements applying to the project.
Rally Poly Dampcourse Selection Guide
Find the specified width first, then choose the roll length that best matches the required runs.
|
Roll Length
|
Current Rally Widths
|
Base Thickness
|
Construction
|
|
30m
|
110mm, 150mm, 230mm, 300mm, 350mm, 380mm
|
500UM
|
Embossed polyethylene
|
|
50m
|
110mm, 150mm, 230mm, 300mm, 380mm, 450mm, 600mm
|
500UM
|
Embossed polyethylene
|
Not every width is offered in both lengths. The current range includes a 350mm x 30m option while 450mm & 600mm formats sit within the 50m range.
Choosing The Right Dampcourse Width
The construction detail should decide the width rather than whichever roll happens to be closest on the shelf. A 110mm DPC roll & a 600mm roll share the same base material specification but serve very different dimensional requirements.
Before ordering, confirm:
► Required DPC width
► Brick or blockwork detail
► Wall construction
► Window or door flashing detail where applicable
► Plans & project specifications
► Required total length
► Number of separate runs
► Quantity required at each width
For setting out wall dimensions, openings & construction lines before work progresses, Measuring & Layout Tools can support the wider preparation process.
Avoid automatically substituting one width for another. Where project documentation calls for a particular DPC dimension, purchase against that requirement.
30m Or 50m Dampcourse?
Roll length becomes important after the correct width is established. Rally provides both 30m & 50m formats across several widths, allowing quantity to be planned around the scale of the work.
A 30m roll can suit:
► Shorter runs
► Smaller projects
► Individual construction stages
► Limited concealed-flashing requirements
► Maintenance or renovation work
A 50m roll can suit:
► Longer project requirements
► Larger building works
► Repeated DPC installation
► Trade stock replenishment
► Commercial project purchasing
Calculate the total required length rather than assuming the longest roll is automatically the better choice. Separate walls, openings & construction stages can change how much material is actually needed.
Understanding 500UM & Embossed Thickness
Two thickness figures describe different measurements of the same Rally dampcourse. The polyethylene has a 0.5mm or 500UM base thickness while Rally specifies an approximately 0.75mm embossed thickness.
In practical terms:
► 500UM refers to the base material
► 0.5mm is the equivalent base thickness
► Embossing increases the overall profile
► Approximately 0.75mm describes the embossed thickness
► Width & roll length remain separate product specifications
Keep the manufacturer's distinction intact when comparing or ordering DPC. Describing the product only by its embossed profile can obscure the 500UM base specification used to identify the range.
Dampcourse For Brickwork & Blockwork
Moisture control should be considered before the wall reaches the point where the DPC needs to be incorporated. Poly dampcourse is used in masonry construction where the applicable detail calls for a damp proof course.
Projects involving broader building preparation may also require products from Formwork & Shuttering Supplies where concrete forming work forms part of the surrounding construction sequence.
Wall appearance alone isn't enough to determine the correct dampcourse width. Bricklayers & builders should work from the applicable construction detail, specification & required coverage rather than selecting DPC purely from nominal masonry dimensions.
Poly Dampcourse As Concealed Flashing
Windows & doors introduce moisture-control junctions of their own. Rally identifies its polythene dampcourse for concealed flashing applications around openings in addition to its damp-proof role.
Relevant applications can include:
► Concealed window flashing
► Concealed door flashing
► Moisture-control junctions
► Building details specifying compatible polyethylene flashing
The word concealed matters. Rally's stated use shouldn't be expanded into an exposed-flashing claim without supporting product documentation.
Where a project includes additional exterior sealing or repair work around existing building elements, Concrete Repair & Restoration may be relevant elsewhere in the repair sequence, provided those products match the actual substrate & defect being addressed.
AS 2904-1986 Conformance
Standards information should remain tied to the exact product being purchased. Rally states that its Poly Dampcourse conforms with the requirements of AS 2904-1986.
Product conformance is only one part of a correct building detail. Width, positioning, continuity, installation & surrounding construction still need to meet the applicable project requirements.
Planning Quantity Across The Build
One building can require several DPC widths rather than one combined metre figure. Walls, openings & separate construction details should be measured against the required width before roll quantities are calculated.
A practical take-off can consider:
► Total run at each width
► Number of wall sections
► Window & door details
► Separate construction stages
► Required roll length
► Installation allowances identified by the project detail
Calculate each width separately. That makes ordering easier to verify & reduces the risk of having enough total metres but not enough of the dimension needed for the next construction stage.
Builders putting together broader site kits can also compare Builder’s Tool Sets where a complete working set is more practical than sourcing individual hand tools separately.
Working Around Concrete & Masonry Stages
Dampcourse frequently sits within a larger sequence of slab, masonry & finishing work. Keeping those stages coordinated makes material purchasing easier than treating the DPC as an isolated item.
Where the project includes inspection or remediation of surrounding concrete, Concrete Repair & Restoration can support separate concrete-repair requirements.
For tasks involving concrete work around the installation stage, Safety & Personal Protective Equipment provides another relevant path for site protection requirements.
Select each supporting product around the task it is actually intended to perform. Dampcourse, repair products & protective equipment serve different roles within the construction sequence.
Poly Dampcourse For Trade & Commercial Buyers
DPC becomes a repeat purchasing item when brickwork, masonry or building projects move through several stages. Builders, bricklayers, contractors & commercial construction buyers can use Rally product dimensions to plan project quantities & replenishment more accurately.
Relevant buyers can include:
► Bricklayers
► Builders
► Blocklayers
► Masonry contractors
► Renovation contractors
► Construction companies
► Property-maintenance teams
► Commercial building buyers
Exact product identification becomes particularly useful when several similar black rolls are stored together. Recording the Rally product code with width & roll length reduces ambiguity on repeat orders.
Businesses purchasing construction consumables regularly can review Trade exclusives for current trade-focused options available through Industrial Shed.
Expert Tips
Read the detail before selecting the roll. DPC width should follow the construction requirement rather than product availability alone.
Choose width before length. Establish the required dampcourse dimension before deciding between 30m & 50m formats.
Keep 500UM separate from the embossed profile. Rally specifies 0.5mm base material with an approximately 0.75mm embossed thickness.
Calculate different widths individually. A project using several DPC dimensions needs a separate quantity for each.
Treat concealed flashing as a specific application. Don't assume the material is intended for exposed flashing without supporting specification.
Keep the product code with purchasing records. Similar-looking rolls can have substantially different widths & lengths.