Foam Sealing Strips for Roofing, Cladding & Construction
Closing a gap properly starts with choosing foam that matches the shape, width & installation. Rally foam sealing strips include PVC nitrile foam strips, adhesive-backed foam & profiled roof closure foam strips for suitable roofing, cladding, construction, HVAC, maintenance & general sealing work. The range includes continuous 25mm, 35mm & 55mm foam strips plus SUN5, SUN11 & SUNCORR closures shaped for compatible roofing profiles.
Planning the wider installation? Roofing Materials & Sealants provides complementary roofing products, while Weatherproofing Supplies covers related materials for suitable building joints & exposed interfaces.
PVC nitrile foam strips suit continuous sealing, cushioning & isolation interfaces, while profiled roof closure foam is shaped to follow compatible roofing sheet profiles. Start with the gap or profile, then select the foam format, width, thickness, length & adhesive option required.
What Are Rally Foam Sealing Strips?
Not every building gap needs liquid sealant or expanding aerosol foam.
Rally Foams are flexible strip & closure products for suitable gaps, joints & interfaces. The collection combines continuous PVC nitrile foam, adhesive-backed PVC nitrile strips & shaped roof closure foam for compatible profiled roofing.
Current options include:
► 25mm, 35mm & 55mm PVC nitrile foam
► 13mm thickness across the listed continuous foam range
► 10m non-adhesive rolls
► 5m adhesive-backed rolls
► SUN5 roof closure foam
► SUN11 roof closure foam
► SUNCORR roof closure foam
► Black & white closure options
These products are designed around strip sealing & profile closure applications rather than filling large cavities like aerosol expanding foam.
Rally Foam Selection Guide
Unsure which Rally foam belongs on the job? Start here.
|
Product Type
|
Size / Profile
|
Adhesive
|
Best Suited To
|
|
PVC nitrile foam
|
25mm x 13mm x 10m
|
No
|
Narrow continuous sealing, cushioning & isolation interfaces
|
|
PVC nitrile foam
|
35mm x 13mm x 10m
|
No
|
Medium-width continuous joints & interfaces
|
|
PVC nitrile foam
|
55mm x 13mm x 10m
|
No
|
Wider contact surfaces & sealing interfaces
|
|
Adhesive PVC nitrile foam
|
25mm x 13mm x 5m
|
Yes
|
Narrow applications where initial positioning assistance is useful
|
|
Adhesive PVC nitrile foam
|
35mm x 13mm x 5m
|
Yes
|
Medium-width adhesive-backed sealing applications
|
|
Adhesive PVC nitrile foam
|
55mm x 13mm x 5m
|
Yes
|
Wider interfaces requiring adhesive-backed positioning
|
|
Roof closure foam
|
SUN5 profile
|
Profile-specific
|
Compatible SUN5 roofing interfaces
|
|
Roof closure foam
|
SUN11 profile
|
Profile-specific
|
Compatible SUN11 roofing interfaces
|
|
Roof closure foam
|
SUNCORR profile
|
Profile-specific
|
Compatible corrugated roofing interfaces
|
The key difference: continuous PVC nitrile foam is selected primarily by dimensions & installation requirements, while roofing closure foam is selected by compatible sheet profile.
Rally PVC Nitrile Foam Strips
Continuous Foam for Sealing, Cushioning & Isolation
Long joints don't always follow a roofing profile.
Rally PVC nitrile foam provides a continuous flexible strip that can be cut to length for suitable sealing, cushioning, insulation & isolation applications.
Current non-adhesive sizes include:
► 25mm x 13mm x 10m
► 35mm x 13mm x 10m
► 55mm x 13mm x 10m
Depending on the installation, PVC nitrile foam can suit applications across:
► Roofing
► Cladding
► General construction
► HVAC installations
► Equipment interfaces
► Building maintenance
► Cushioning between suitable components
► Gap isolation
► Vibration-reduction applications
A wider strip isn't automatically better. Match the foam to the contact surface, joint geometry & required compression.
Rally Adhesive-Backed PVC Nitrile Foam
Easier Positioning Across Long Runs
Holding foam in alignment while another component is being positioned can make a simple installation unnecessarily awkward.
Rally adhesive-backed PVC nitrile foam adds a self-adhesive surface to assist initial positioning on a suitable prepared substrate.
Available sizes include:
► 25mm x 13mm x 5m
► 35mm x 13mm x 5m
► 55mm x 13mm x 5m
Adhesive backing is particularly useful where a continuous strip needs to remain positioned during assembly.
It shouldn't be confused with structural fastening. Components that require mechanical attachment still need the appropriate fixing system.
Choosing Between 25mm, 35mm & 55mm Foam
Measure the actual interface before reaching for a roll.
25mm Foam
A narrower 25mm strip can suit smaller contact areas where wider foam would be unnecessary or difficult to position neatly.
35mm Foam
The 35mm option provides additional coverage for medium-width joints & interfaces.
55mm Foam
Wider surfaces can call for the increased contact area available from a 55mm strip.
All three listed continuous Rally foam widths use a 13mm thickness, making width, thickness & available compression important selection considerations.
What Are Roof Closure Foam Strips?
Look underneath a profiled roofing sheet & the reason for a shaped closure becomes obvious.
Corrugated & other profiled sheets create repeating peaks & valleys where they meet flatter building components. Roof closure foam strips are shaped to follow compatible roofing profiles, helping close suitable openings more effectively than rectangular foam.
The Rally range includes:
► SUN5 end closure foam
► SUN11 end closure foam
► SUNCORR end closure foam
► Black options
► White options
► Packs of 4 pieces
These closures are selected by roof-sheet profile first.
Colour becomes a secondary consideration where the closure may remain visible.
Why Roofing Profile Compatibility Matters?
A closure strip can't seal a profile it doesn't follow properly.
An incompatible closure can create:
► Unclosed sections
► Poor seating
► Excessive compression in some areas
► Little or no contact in others
► Distorted foam
► Visible gaps
► Difficult installation
Identify the roofing sheet profile before ordering.
For related installation equipment, Roofing Tools & Accessories provides supporting products for roofing, installation & maintenance work.
Black vs White Roof Closure Foam
Appearance matters after compatibility has been confirmed.
Black foam can suit darker roof details or areas where a dark closure is preferred. White foam can better complement lighter finishes where the closure remains visible.
Don't select by colour before checking profile.
A perfectly matched colour won't compensate for the wrong closure shape.
Common Applications for Rally Foams
Roofing
Roof closure foam can help close suitable openings created by compatible profiled sheets.
Continuous PVC nitrile foam can serve other roofing interfaces where a rectangular flexible strip better matches the joint.
Cladding
Sheet cladding can create interfaces where flexible foam helps separate components or close suitable gaps.
Check dimensions, compression & material compatibility before installation.
HVAC Installations
Ductwork, equipment housings & associated components can require flexible foam between adjoining surfaces.
PVC nitrile foam provides continuous strip options where its properties & dimensions suit the installation.
Construction
Building work can create joints where a compressible strip is more appropriate than filling the entire space with a liquid or expanding material.
Select according to the joint rather than treating all foam products as interchangeable.
Maintenance
Existing foam can deteriorate, move, tear or lose contact over time.
Before replacing it, determine whether the original problem came from age, incorrect sizing, excessive movement, poor surface preparation or an unsuitable product.
Equipment Interfaces
Suitable foam can provide cushioning or separation between components.
Compression still needs to remain appropriate rather than crushing the foam beyond its useful working condition.
Foam Strip vs Sealant
Both can be useful, but they solve joints differently.
|
Foam Strip
|
Sealant
|
|
Supplied at a defined thickness
|
Dispensed into or across a joint
|
|
Can provide compression & cushioning
|
Cures in place where compatible
|
|
Continuous rolls available
|
Conforms to suitable irregular joints
|
|
Profiled roofing versions available
|
Useful around compatible seams & penetrations
|
|
Can separate adjoining components
|
Bonds to compatible joint surfaces
|
Some installations use both products as part of a wider system.
For complementary bonding & sealing materials, Adhesives & Tapes provides options for construction, roofing, workshop & maintenance work.
Before Installing Adhesive Foam
Good adhesive contact starts before the backing comes off.
Check the installation surface for:
► Loose dust
► Dirt
► Oil or grease
► Moisture
► Existing failed adhesive
► Loose coatings
► Irregularities that prevent consistent contact
Measure the complete run & trial-position the strip where practical.
Once installation begins, remove the backing progressively rather than exposing the adhesive along the entire length at once.
Installing Continuous Foam Strips
Long foam runs reward controlled placement.
► Measure the required length
► Cut the strip cleanly
► Confirm its position
► Start from a consistent reference point
► Remove backing progressively on adhesive versions
► Keep the foam aligned
► Press adhesive foam into consistent contact
► Avoid stretching the strip
► Keep joins neat
► Check corners & transitions
Flexible foam can retract if stretched during installation.
Place it naturally rather than pulling it tight around the joint.
Installing Roof Closure Foam
Profile closures require a different approach.
Before fitting:
► Identify the roofing profile
► Confirm closure compatibility
► Check the required closure position
► Prepare the installation area
► Align the foam with the sheet geometry
► Check that peaks & valleys correspond correctly
► Avoid leaving sections displaced from the profile
► Complete fastening & sealing according to the roofing system
Where roof sheets require mechanical fixing, Roofing Nails & Fasteners provides related fastening options for suitable roofing applications.
Foam Compression Matters
More compression isn't automatically more sealing.
Foam needs appropriate contact with adjoining surfaces while retaining enough material structure to perform its intended role.
Excessive compression can:
► Distort the strip
► Make alignment difficult
► Reduce useful cushioning
► Create uneven loading
► Push foam away from the intended position
Too little contact can leave gaps.
Select dimensions with the installed condition in mind rather than measuring only the open space.
Don't Use Foam to Hide a Larger Problem
A visible gap can sometimes be the symptom rather than the fault.
Before closing it, check for:
► Loose roof sheets
► Failed fasteners
► Corrosion
► Damaged cladding
► Structural movement
► Incorrect sheet alignment
► Deteriorated flashings
► Failed surrounding sealants
► Water entering from another location
Repair the underlying defect where necessary before installing new foam.
A closure strip should close an appropriate interface, not conceal failed building components.
Cutting Foam Strips Cleanly
A rough end can leave an otherwise neat run looking unfinished.
Measure the foam in its relaxed state & use an appropriate sharp cutting tool to create a controlled edge.
Avoid heavily compressing or stretching the strip while measuring.
For general installation equipment, Hand Tools covers tools used across roofing, construction & maintenance work.
Expert Tips for Better Foam Sealing
Start With the Gap
Measure width, depth, profile & available contact area before selecting foam.
Match Profile Before Colour
For roofing closures, SUN5, SUN11 or SUNCORR compatibility comes before choosing black or white.
Keep Adhesive Surfaces Clean
Dust, oil & contamination can interfere with contact between the backing & substrate.
Don't Stretch Continuous Foam
Install flexible strips in a relaxed state to reduce the chance of later shrink-back.
Plan Roll Joins
Know where one length will finish before installation begins.
Keep joins controlled rather than leaving an avoidable opening.
Check Compression
Aim for suitable contact without unnecessarily crushing the foam.
Diagnose Failed Existing Foam
If old foam moved, tore or lost contact, determine why before installing an identical replacement.
Common Foam Selection & Installation Mistakes
Choosing by width alone? Check thickness, length, compression & application.
Ordering roof closures by appearance? Identify the sheet profile first.
Applying adhesive foam over dust? Prepare the substrate before installation.
Stretching the strip into position? Lay flexible foam naturally.
Using adhesive backing instead of mechanical fixing? Fasten components according to their installation requirements.
Crushing the foam completely? Use appropriate compression.
Replacing failed foam without inspecting the joint? Find the reason for the original failure.
Treating strip foam like expanding foam? Rally's collection contains foam strips & profiled closures rather than spray-applied cavity filler.