► Rally | Angle Flashing

Zinc Corner Flashing for Roofing, Walling & Building Finishes Corners are where an otherwise tidy sheet-metal job can start looking unfinished. Rally Angle Flashing provides a straightforward zinc flashing solution for external building corners, roof edges, wall cladding & sheet junctions where the exposed edge needs to be covered &...

Zinc Corner Flashing for Roofing, Walling & Building Finishes

Corners are where an otherwise tidy sheet-metal job can start looking unfinished. Rally Angle Flashing provides a straightforward zinc flashing solution for external building corners, roof edges, wall cladding & sheet junctions where the exposed edge needs to be covered & finished cleanly.

Made from zinc-coated steel, Rally angle flashing is supplied in 2400mm lengths across multiple equal-angle sizes, giving builders, roofers, shed installers & maintenance crews practical options for different corner dimensions. Use the profile to finish compatible roofing & walling installations while helping direct water away from vulnerable junctions.

For the wider roof system, Roofing Materials & Sealants covers complementary materials, while Weatherproofing Supplies provides additional products for protecting exposed building junctions.

What Is Rally Angle Flashing?

Rally Angle Flashing is a folded metal profile used to cover & finish external corners & junctions on compatible building, roofing & walling applications.

Its simple right-angle form makes it useful wherever two surfaces meet around a corner & require a durable metal finish.

Rather than leaving the edge of sheet cladding exposed, correctly selected flashing can help:

► Cover exposed sheet edges
► Create a cleaner external corner
► Help shed water away from junctions
► Finish roof & wall intersections
► Protect vulnerable building edges
► Provide a consistent metal finish
► Reduce reliance on sealant alone at exposed junctions

Flashing is part of the overall building-envelope detail. Its effectiveness depends on choosing the correct size, orientation, overlap, fasteners & sealing method for the particular installation.

Rally Angle Flashing Sizes

One of the advantages of a simple angle profile is that sizing is easy to understand.

Rally's zinc angle flashing range includes:

Size

Length

Typical Selection Consideration

50mm x 50mm

2400mm

Compact corners & smaller sheet-edge details

75mm x 75mm

2400mm

General walling & building corner applications

100mm x 100mm

2400mm

Broader corner coverage

150mm x 150mm

2400mm

Larger junctions requiring wider coverage

The Rally range is manufactured from zinc-coated steel, with material gauge across the range approximately 0.47mm to 0.7mm depending on the product configuration.

Don't choose the leg width simply because it looks proportional to the building.

The flashing needs enough coverage for the actual junction, sheet profile, fastening position, overlap & weather exposure.

Which Angle Flashing Size Should You Choose?

Before ordering, stand at the corner with a tape measure.

That's considerably more useful than trying to estimate the profile from a photo.

50mm x 50mm

A compact equal-angle profile for compatible corners where a smaller amount of coverage is required.

It can suit neat finishing details where the flashing doesn't need to extend far across either adjoining surface.

75mm x 75mm

The additional leg width provides more coverage while keeping the profile relatively compact.

This can make 75mm angle flashing useful across general building, shed & wall-cladding work.

100mm x 100mm

A wider profile gives more material on both sides of the corner.

Consider it where the installation requires additional coverage for the sheet edge, fixing position or junction detail.

150mm x 150mm

The largest listed Rally equal-angle size provides considerably broader coverage.

It can suit larger external corners & building details where narrower flashing doesn't provide the required overlap.

Bigger isn't automatically better.

An oversized profile can interfere with adjoining components or create an unnecessarily bulky finish. Measure the actual junction & choose accordingly.

Where Rally Angle Flashing Earns Its Place

Steel-Clad Sheds

Sheds create plenty of exposed sheet-metal junctions.

Angle flashing can provide a neat finish at suitable external corners while covering the cut or exposed edges of wall cladding.

Garages & Workshops

Metal-clad garages, workshops & outbuildings need more than sheets screwed to a frame.

Corners, transitions & exposed edges are where finishing components become important.

Rally Angle Flashing can form part of those finishing details where an equal-angle profile suits the construction.

External Wall Corners

Where two compatible wall-cladding surfaces meet at an external corner, angle flashing can cover the junction & create a more consistent finished edge.

Roof-to-Wall Junctions

Certain roof & wall details can use angle flashing as part of the junction treatment.

The exact flashing arrangement needs to suit roof pitch, sheet profile, water path & construction detail rather than relying on a generic corner treatment for every roof.

Sheet-Metal Fabrication

A standard angle profile can also be useful around suitable fabricated covers, enclosures & building-related sheet-metal work where a folded zinc edge is required.

Maintenance & Repairs

Storm damage, corrosion, impact or previous poor workmanship can leave existing flashing needing replacement.

Before copying the old piece, check whether it was actually sized & installed correctly.

Replacing a poor detail exactly as it was found simply reproduces the problem.

Angle Flashing vs Flat Flashing

Both are sheet-metal products, but they're useful for different details.

Angle Flashing

Already folded into an angle, making it practical for compatible corners & junctions.

It provides defined legs on both sides of the fold.

Flat Flashing

Supplied flat & suited to applications where a different fold, cover strip or site-specific detail is required.

If the job already calls for a straightforward equal corner, pre-formed angle flashing can save the need to create that basic fold on site.

If the junction requires multiple folds, an unusual angle or a complex profile, a standard equal-angle product may not be the correct solution.

Angle Flashing vs Roof Capping

They may both cover exposed roofing details, but they aren't automatically substitutes.

Angle flashing is a simple folded profile commonly used around corners & compatible junctions.

Roof capping is shaped for particular roof details such as ridges, barges or other sheet transitions.

Choose the profile that matches the building detail rather than trying to make a convenient piece of folded metal fit every junction.

Angle Flashing vs Sealant

This isn't an either-or decision.

A bead of sealant isn't a substitute for correctly detailed metal flashing where flashing is required.

Likewise, installing flashing doesn't mean every joint automatically becomes watertight without considering overlaps, fasteners, sheet profiles & compatible sealing products.

For junctions requiring an appropriate sealant as part of the installation, Roof Sealants & Adhesives provides complementary products.

The objective is a complete detail, not simply more sealant.

Before Cutting the First Length

A 2400mm flashing can disappear surprisingly quickly if cuts aren't planned.

Start by measuring the complete run.

Then establish:

► Required finished lengths
► Number of full 2400mm sections
► Overlap requirements
► Corner transitions
► End details
► Sheet profile
► Fixing locations
► Potential offcut reuse

Planning the cuts across several corners can reduce waste.

A short offcut from one wall may be exactly what the next small junction needs.

Cutting Rally Angle Flashing

Use tools suitable for the metal, coating & quality of finish required.

The goal isn't merely to separate one piece from another.

You want a controlled cut without unnecessary distortion or damage.

Before cutting:

► Mark the line clearly
► Support the flashing
► Protect the finished surface
► Use suitable sheet-metal cutting equipment
► Keep the profile from twisting
► Remove dangerous sharp edges afterwards

Avoid treating every cutting tool as interchangeable.

Some methods can leave rough edges, distort thin sheet or unnecessarily damage protective coatings.

Roofing Tools & Accessories provides equipment for broader roofing & sheet-metal installation work.

Fixing Angle Flashing Correctly

The fastener has to suit what sits behind the flashing.

That could involve timber, light-gauge steel or another compatible substrate depending on the building.

Before selecting the screw, establish:

► Substrate material
► Combined material thickness
► Required drilling capacity
► Head style
► Washer or sealing requirement
► Corrosion environment
► Installation location

For compatible steel-to-steel applications, Self-Drilling Screws provides options that can reduce the need for separate pilot drilling where the screw's drilling capacity suits the material.

For wider fastening requirements, Screws & Anchors covers additional fixing types.

The Fastener Is Part of the Weather Detail

Putting a screw through flashing creates a penetration.

That means screw selection & installation deserve attention.

Depending on the application, compatible roofing fasteners may incorporate sealing washers to help seal around the fixing.

Roofing Nails & Fasteners provides purpose-specific options for roofing & cladding work.

Avoid:

► Under-driving fasteners & leaving sealing components loose
► Excessively crushing sealing washers
► Driving screws on an angle
► Using fasteners unsuited to the substrate
► Mixing incompatible metals without considering corrosion
► Assuming every roofing screw has the same drilling capacity

A neat flashing installation can still leak if the fixing detail is poor.

Expert Tips for Cleaner Corner Flashing

Measure the Actual Building, Not the Drawing Alone

Frames, sheets & previous construction work can introduce small dimensional differences.

Confirm critical measurements on the structure before cutting every piece.

Think Like Water

Before fixing the flashing, picture where rain will travel.

Ask:

► Which surface receives the weather?
► Where will water run?
► Could it move behind the flashing?
► Are overlaps facing the right direction?
► Is there a low point where water could collect?

A flashing detail should encourage water to move away from the junction rather than trap it.

Keep the Fold Straight

A kink in a long angle profile is difficult to hide once it's fixed against straight wall sheets.

Support long sections during handling & installation.

Don't Overtighten the Fixings

Pulling a fastener too hard can distort thin flashing or deform sealing components.

Install the selected fastener according to its intended fixing method.

Check the Corner Before Drilling

If the building corner isn't square, forcing a standard angle against it can leave gaps or distort the profile.

Identify the problem before the first fixing locks the flashing into position.

Protect Cut Edges

Follow the relevant material recommendations where cutting exposes steel or damages the protective surface.

Don't leave heavily damaged edges simply because they'll be above eye level.

Common Installation Problems

Flashing rocks against the corner? Check whether the underlying junction is straight & compatible with the profile.

Water is getting behind the flashing? Review overlaps, orientation, fixing penetrations & the complete junction detail.

Screws are pulling through the metal? Check fastener head, installation force & substrate.

Angle looks wavy after fixing? Fasteners may be pulling the profile against an uneven surface or being installed with excessive force.

Cut edge is rough? Dress sharp edges appropriately before installation.

Sealant keeps failing? Investigate movement, surface preparation, compatibility & whether the metal flashing detail itself is correct.

Existing corner keeps leaking after repairs? Stop treating the visible gap alone & inspect the path water is taking through the complete junction.

For broader fastening considerations around roofing & sheet-metal work, Why Good Fasteners Matter More Than the Tool You Drive Them With explains why the fixing deserves as much thought as the material being installed.

Plan Long Lengths Before Working at Height

Handling a 2400mm piece of metal at ground level is one thing.

Doing it beside a roof edge is another.

Plan the cut, tools, access & lifting method before moving long flashing into position.

For work requiring ladders or other access equipment, Roof Access Equipment covers equipment for appropriate roof-access tasks.

How To Choose Right Ladder Access Equipment also provides practical guidance when planning access for building & maintenance work.

Rally Angle Flashing for Roofers, Builders & B2B Supply

On a completed shed, nobody should be staring at the corner wondering how the sheets were meant to finish.

Industrial Shed is an Australian B2B supplier of industrial tools, hardware, fasteners, roofing products, sealants & trade consumables, supporting roofers, builders, shed installers, fabricators, maintenance crews & procurement teams with project materials & recurring supply.

Rally Angle Flashing is relevant across:

► Shed construction
► Steel wall cladding
► Garages & workshops
► External building corners
► Roofing junctions
► Sheet-metal finishing
► Commercial maintenance
► Building repairs
► Contractor stock

For eligible trade businesses managing repeat purchasing, Application for Credit Account provides an option for ongoing requirements.

Where timing matters, Same day dispatch provides current information about Industrial Shed's dispatch & delivery process.

Crews preparing roofing materials, fixings & equipment before a busy run of jobs may also find Spring Jobsite Prep Getting Your Gear Ready useful.

Make the Corner Look Planned, Not Patched

✔ Measure both sides of the junction
✔ Choose enough leg width for proper coverage
✔ Plan cuts across the full 2400mm length
✔ Keep overlaps working with the water path
✔ Match fasteners to the substrate
✔ Use compatible sealing products where required
✔ Avoid distorting the flashing during fixing
✔ Check long lengths remain straight before final tightening
✔ Inspect the finished junction from above as well as below

A clean corner is the result of getting the flashing size, cut, fixing & water path right before the first screw goes in.

Frequently Asked Questions

What sizes are available in Rally Angle Flashing?

The Rally zinc range includes 50 x 50mm, 75 x 75mm, 100 x 100mm & 150 x 150mm equal-angle profiles in 2400mm lengths.

Where is angle flashing commonly installed?

It can be used on suitable external building corners, steel wall-cladding edges, roof & wall junctions, sheds, garages & other sheet-metal finishing details where an angle profile is appropriate.

Is Rally Angle Flashing galvanised?

The Rally product is described as zinc angle flashing. Select the material & coating according to the actual installation environment rather than assuming all metallic coatings provide identical protection.

Should I use 50mm or 100mm angle flashing?

Choose according to the amount of coverage required on each side of the corner. Consider sheet profile, fixing position, overlap, weather exposure & the dimensions of the actual junction.

Can angle flashing stop a roof or wall leak by itself?

Not necessarily. Effective weatherproofing depends on the complete detail, including flashing orientation, overlaps, fasteners, penetrations, adjoining materials & any compatible sealant required.

What should I use to fix angle flashing to steel framing or cladding?

Use a fastener designed for the substrate, combined material thickness & exposure conditions. For suitable metal-to-metal work, a correctly specified self-drilling screw may be appropriate.

Brands

► Rally | Angle Flashing

Zinc Corner Flashing for Roofing, Walling & Building Finishes

Corners are where an otherwise tidy sheet-metal job can start looking unfinished. Rally Angle Flashing provides a straightforward zinc flashing solution for external building corners, roof edges, wall cladding & sheet junctions where the exposed edge needs to be covered & finished cleanly.

Made from zinc-coated steel, Rally angle flashing is supplied in 2400mm lengths across multiple equal-angle sizes, giving builders, roofers, shed installers & maintenance crews practical options for different corner dimensions. Use the profile to finish compatible roofing & walling installations while helping direct water away from vulnerable junctions.

For the wider roof system, Roofing Materials & Sealants covers complementary materials, while Weatherproofing Supplies provides additional products for protecting exposed building junctions.

What Is Rally Angle Flashing?

Rally Angle Flashing is a folded metal profile used to cover & finish external corners & junctions on compatible building, roofing & walling applications.

Its simple right-angle form makes it useful wherever two surfaces meet around a corner & require a durable metal finish.

Rather than leaving the edge of sheet cladding exposed, correctly selected flashing can help:

► Cover exposed sheet edges
► Create a cleaner external corner
► Help shed water away from junctions
► Finish roof & wall intersections
► Protect vulnerable building edges
► Provide a consistent metal finish
► Reduce reliance on sealant alone at exposed junctions

Flashing is part of the overall building-envelope detail. Its effectiveness depends on choosing the correct size, orientation, overlap, fasteners & sealing method for the particular installation.

Rally Angle Flashing Sizes

One of the advantages of a simple angle profile is that sizing is easy to understand.

Rally's zinc angle flashing range includes:

Size

Length

Typical Selection Consideration

50mm x 50mm

2400mm

Compact corners & smaller sheet-edge details

75mm x 75mm

2400mm

General walling & building corner applications

100mm x 100mm

2400mm

Broader corner coverage

150mm x 150mm

2400mm

Larger junctions requiring wider coverage

The Rally range is manufactured from zinc-coated steel, with material gauge across the range approximately 0.47mm to 0.7mm depending on the product configuration.

Don't choose the leg width simply because it looks proportional to the building.

The flashing needs enough coverage for the actual junction, sheet profile, fastening position, overlap & weather exposure.

Which Angle Flashing Size Should You Choose?

Before ordering, stand at the corner with a tape measure.

That's considerably more useful than trying to estimate the profile from a photo.

50mm x 50mm

A compact equal-angle profile for compatible corners where a smaller amount of coverage is required.

It can suit neat finishing details where the flashing doesn't need to extend far across either adjoining surface.

75mm x 75mm

The additional leg width provides more coverage while keeping the profile relatively compact.

This can make 75mm angle flashing useful across general building, shed & wall-cladding work.

100mm x 100mm

A wider profile gives more material on both sides of the corner.

Consider it where the installation requires additional coverage for the sheet edge, fixing position or junction detail.

150mm x 150mm

The largest listed Rally equal-angle size provides considerably broader coverage.

It can suit larger external corners & building details where narrower flashing doesn't provide the required overlap.

Bigger isn't automatically better.

An oversized profile can interfere with adjoining components or create an unnecessarily bulky finish. Measure the actual junction & choose accordingly.

Where Rally Angle Flashing Earns Its Place

Steel-Clad Sheds

Sheds create plenty of exposed sheet-metal junctions.

Angle flashing can provide a neat finish at suitable external corners while covering the cut or exposed edges of wall cladding.

Garages & Workshops

Metal-clad garages, workshops & outbuildings need more than sheets screwed to a frame.

Corners, transitions & exposed edges are where finishing components become important.

Rally Angle Flashing can form part of those finishing details where an equal-angle profile suits the construction.

External Wall Corners

Where two compatible wall-cladding surfaces meet at an external corner, angle flashing can cover the junction & create a more consistent finished edge.

Roof-to-Wall Junctions

Certain roof & wall details can use angle flashing as part of the junction treatment.

The exact flashing arrangement needs to suit roof pitch, sheet profile, water path & construction detail rather than relying on a generic corner treatment for every roof.

Sheet-Metal Fabrication

A standard angle profile can also be useful around suitable fabricated covers, enclosures & building-related sheet-metal work where a folded zinc edge is required.

Maintenance & Repairs

Storm damage, corrosion, impact or previous poor workmanship can leave existing flashing needing replacement.

Before copying the old piece, check whether it was actually sized & installed correctly.

Replacing a poor detail exactly as it was found simply reproduces the problem.

Angle Flashing vs Flat Flashing

Both are sheet-metal products, but they're useful for different details.

Angle Flashing

Already folded into an angle, making it practical for compatible corners & junctions.

It provides defined legs on both sides of the fold.

Flat Flashing

Supplied flat & suited to applications where a different fold, cover strip or site-specific detail is required.

If the job already calls for a straightforward equal corner, pre-formed angle flashing can save the need to create that basic fold on site.

If the junction requires multiple folds, an unusual angle or a complex profile, a standard equal-angle product may not be the correct solution.

Angle Flashing vs Roof Capping

They may both cover exposed roofing details, but they aren't automatically substitutes.

Angle flashing is a simple folded profile commonly used around corners & compatible junctions.

Roof capping is shaped for particular roof details such as ridges, barges or other sheet transitions.

Choose the profile that matches the building detail rather than trying to make a convenient piece of folded metal fit every junction.

Angle Flashing vs Sealant

This isn't an either-or decision.

A bead of sealant isn't a substitute for correctly detailed metal flashing where flashing is required.

Likewise, installing flashing doesn't mean every joint automatically becomes watertight without considering overlaps, fasteners, sheet profiles & compatible sealing products.

For junctions requiring an appropriate sealant as part of the installation, Roof Sealants & Adhesives provides complementary products.

The objective is a complete detail, not simply more sealant.

Before Cutting the First Length

A 2400mm flashing can disappear surprisingly quickly if cuts aren't planned.

Start by measuring the complete run.

Then establish:

► Required finished lengths
► Number of full 2400mm sections
► Overlap requirements
► Corner transitions
► End details
► Sheet profile
► Fixing locations
► Potential offcut reuse

Planning the cuts across several corners can reduce waste.

A short offcut from one wall may be exactly what the next small junction needs.

Cutting Rally Angle Flashing

Use tools suitable for the metal, coating & quality of finish required.

The goal isn't merely to separate one piece from another.

You want a controlled cut without unnecessary distortion or damage.

Before cutting:

► Mark the line clearly
► Support the flashing
► Protect the finished surface
► Use suitable sheet-metal cutting equipment
► Keep the profile from twisting
► Remove dangerous sharp edges afterwards

Avoid treating every cutting tool as interchangeable.

Some methods can leave rough edges, distort thin sheet or unnecessarily damage protective coatings.

Roofing Tools & Accessories provides equipment for broader roofing & sheet-metal installation work.

Fixing Angle Flashing Correctly

The fastener has to suit what sits behind the flashing.

That could involve timber, light-gauge steel or another compatible substrate depending on the building.

Before selecting the screw, establish:

► Substrate material
► Combined material thickness
► Required drilling capacity
► Head style
► Washer or sealing requirement
► Corrosion environment
► Installation location

For compatible steel-to-steel applications, Self-Drilling Screws provides options that can reduce the need for separate pilot drilling where the screw's drilling capacity suits the material.

For wider fastening requirements, Screws & Anchors covers additional fixing types.

The Fastener Is Part of the Weather Detail

Putting a screw through flashing creates a penetration.

That means screw selection & installation deserve attention.

Depending on the application, compatible roofing fasteners may incorporate sealing washers to help seal around the fixing.

Roofing Nails & Fasteners provides purpose-specific options for roofing & cladding work.

Avoid:

► Under-driving fasteners & leaving sealing components loose
► Excessively crushing sealing washers
► Driving screws on an angle
► Using fasteners unsuited to the substrate
► Mixing incompatible metals without considering corrosion
► Assuming every roofing screw has the same drilling capacity

A neat flashing installation can still leak if the fixing detail is poor.

Expert Tips for Cleaner Corner Flashing

Measure the Actual Building, Not the Drawing Alone

Frames, sheets & previous construction work can introduce small dimensional differences.

Confirm critical measurements on the structure before cutting every piece.

Think Like Water

Before fixing the flashing, picture where rain will travel.

Ask:

► Which surface receives the weather?
► Where will water run?
► Could it move behind the flashing?
► Are overlaps facing the right direction?
► Is there a low point where water could collect?

A flashing detail should encourage water to move away from the junction rather than trap it.

Keep the Fold Straight

A kink in a long angle profile is difficult to hide once it's fixed against straight wall sheets.

Support long sections during handling & installation.

Don't Overtighten the Fixings

Pulling a fastener too hard can distort thin flashing or deform sealing components.

Install the selected fastener according to its intended fixing method.

Check the Corner Before Drilling

If the building corner isn't square, forcing a standard angle against it can leave gaps or distort the profile.

Identify the problem before the first fixing locks the flashing into position.

Protect Cut Edges

Follow the relevant material recommendations where cutting exposes steel or damages the protective surface.

Don't leave heavily damaged edges simply because they'll be above eye level.

Common Installation Problems

Flashing rocks against the corner? Check whether the underlying junction is straight & compatible with the profile.

Water is getting behind the flashing? Review overlaps, orientation, fixing penetrations & the complete junction detail.

Screws are pulling through the metal? Check fastener head, installation force & substrate.

Angle looks wavy after fixing? Fasteners may be pulling the profile against an uneven surface or being installed with excessive force.

Cut edge is rough? Dress sharp edges appropriately before installation.

Sealant keeps failing? Investigate movement, surface preparation, compatibility & whether the metal flashing detail itself is correct.

Existing corner keeps leaking after repairs? Stop treating the visible gap alone & inspect the path water is taking through the complete junction.

For broader fastening considerations around roofing & sheet-metal work, Why Good Fasteners Matter More Than the Tool You Drive Them With explains why the fixing deserves as much thought as the material being installed.

Plan Long Lengths Before Working at Height

Handling a 2400mm piece of metal at ground level is one thing.

Doing it beside a roof edge is another.

Plan the cut, tools, access & lifting method before moving long flashing into position.

For work requiring ladders or other access equipment, Roof Access Equipment covers equipment for appropriate roof-access tasks.

How To Choose Right Ladder Access Equipment also provides practical guidance when planning access for building & maintenance work.