Secure Bulk Oil Storage for Trade & Industrial Applications
Shop Macnaught Double Skinned Tanks for organised bulk oil storage, lubricant management & workshop dispensing across Australian fleet facilities, machinery workshops, manufacturing plants, agricultural operations & industrial maintenance environments.
Macnaught’s double-wall oil tank range provides dedicated bulk storage across 400L, 750L, 1000L & 1500L capacities, giving businesses multiple options for moving away from smaller drum-based storage towards a more centralised oil-management setup.
The right tank should be selected around lubricant consumption, available floor space, dispensing volume, pump configuration, hose-reel requirements & workshop workflow.
Where powered oil transfer forms part of the system, Macnaught Electric Pumps provides a directly related pathway into compatible powered fluid-transfer equipment.
What Are Macnaught Double Skinned Tanks?
Macnaught Double Skinned Tanks are double-wall bulk fluid storage tanks designed for professional workshop oil-management systems.
The double-wall construction provides an outer containment layer around the primary storage vessel, creating a more purpose-built storage solution than relying solely on individual oil drums.
Current Macnaught tank capacities include:
► 400L double-wall storage tanks
► 750L double-wall storage tanks
► 1000L double-wall storage tanks
► 1500L double-wall storage tanks
Macnaught also offers tank packages that can integrate fluid-handling components around the storage tank.
Depending on the package, a complete setup can include:
► Oil pump
► Hose reel
► Delivery hose
► Oil control gun
► Metered dispensing equipment
► Mounting hardware
► Tank connections
► Supporting fittings
This means the tank can become the foundation of a complete workshop oil-dispensing system rather than functioning only as passive storage.
For measured hose-end dispensing, Macnaught Control Guns provides another directly related pathway.
Why Choose Macnaught Double Skinned Tanks?
Bulk lubricant storage becomes increasingly important as workshop oil consumption rises.
Repeatedly managing multiple drums can create extra handling, storage complexity plus fluid-identification issues.
A dedicated double-skinned tank can centralise lubricant storage around one clearly identified supply point.
► Multiple storage capacities – 400L through to 1500L options support different workshop requirements
► Double-wall construction – provides a secondary containment layer around the primary tank
► Bulk lubricant storage – reduces reliance on multiple smaller containers
► Centralised fluid management – supports more organised oil dispensing
► Integrated dispensing options – selected packages combine tank, pump, reel plus gun
► Workshop scalability – choose capacity around lubricant consumption
► Cleaner system architecture – pumps, hoses plus dispensing equipment can be configured
around one storage point
► Professional oil management – useful where fluid volume justifies dedicated infrastructure
The strongest advantage is not simply storing more oil.
It is creating a controlled path from bulk lubricant storage through to final machine dispensing.
For facilities maintaining broader lubrication infrastructure, Drive Lubrication Systems provides a relevant cross-sell into industrial lubrication equipment.
Common Applications
Macnaught Double Skinned Tanks can suit facilities where lubricant usage is high enough to justify dedicated bulk storage.
Common applications include:
► Automotive workshops
► Fleet maintenance facilities
► Truck workshops
► Heavy-equipment servicing
► Agricultural operations
► Earthmoving maintenance
► Construction plant workshops
► Industrial manufacturing
► Machinery maintenance
► Mining support facilities
► Quarry workshops
► Hydraulic oil storage
► Engine oil storage
► Gear oil storage
► Workshop lubricant rooms
► Bulk oil dispensing
► Preventative-maintenance facilities
► High-volume servicing
Tank capacity should reflect actual lubricant turnover.
A smaller workshop can benefit from a 400L system while a larger fleet or industrial maintenance operation can justify 1000L or 1500L storage.
For facilities managing larger equipment servicing, Material Handling Equipment provides a useful supporting category.
Industrial teams working around high-use machinery can also read Quarry Crews Crusher Maintenance for relevant maintenance context.
Product Selection Guide
Choosing the right Macnaught Double Skinned Tank starts with lubricant usage rather than maximum capacity.
1. Calculate oil consumption
Review how much lubricant the facility uses across:
► Weekly servicing
► Monthly servicing
► Fleet maintenance
► Scheduled machinery work
► Seasonal demand
► Major service intervals
► Production maintenance
► Emergency top-ups
Use realistic consumption data rather than estimating from workshop size alone.
2. Choose the right tank capacity
Current Macnaught options include:
400L
Can suit:
► Smaller workshops
► Lower lubricant consumption
► Dedicated storage for one frequently used oil
► Facilities transitioning from drum-based storage
750L
Can suit:
► Medium-volume workshops
► Fleet servicing
► Agricultural operations
► Machinery-maintenance facilities
1000L
Can suit:
► Larger automotive operations
► Fleet depots
► Industrial maintenance
► Higher-volume lubricant use
1500L
Can suit:
► Major fleet operations
► Manufacturing facilities
► Heavy plant servicing
► High-volume industrial lubricant storage
Choose enough capacity to support the operating cycle without creating unnecessary storage volume.
3. Identify the lubricant
A bulk tank should normally be assigned to a clearly identified compatible fluid.
Potential workshop applications can include:
► Engine oil
► Hydraulic oil
► Gear oil
► Other approved lubricants
Use clear product identification across:
► Tank
► Pump
► Reel
► Hose
► Control gun
► Workshop documentation
Bulk storage magnifies the consequences of filling a system with the wrong lubricant.
4. Plan the tank location
Tank positioning influences the entire dispensing system.
Consider:
► Delivery access
► Workshop floor space
► Pump location
► Hose-reel position
► Technician travel
► Vehicle movement
► Machinery movement
► Service-bay access
► Maintenance access
► Existing infrastructure
The tank should be positioned around safe access plus practical fluid distribution.
5. Decide how oil will be pumped
A tank needs a compatible dispensing method.
Depending on the system, this can include:
► Air-operated oil pump
► Electric oil pump
► Compatible bulk-fluid pump
Pump selection should consider:
► Oil viscosity
► Required flow
► Transfer distance
► Hose length
► Workshop throughput
► Available power source
► Required pressure
For broader workshop fluid transfer, Macnaught Pumps & Guns provides another useful cross-sell.
6. Consider hose-reel integration
A hose reel can extend lubricant delivery from the tank towards service bays.
Consider:
► Hose length
► Hose diameter
► Oil compatibility
► Reel pressure rating
► Mounting position
► Technician work area
► Number of service bays
A central tank with a poorly positioned reel can still create an inefficient workshop setup.
7. Decide whether metered dispensing is required
Metered oil delivery can help where technicians need visibility over fluid quantity.
This can support:
► Known service-fill volumes
► Fleet servicing
► Workshop lubricant tracking
► Machinery maintenance
► Internal fluid accountability
A metered control gun or inline meter can be integrated into a compatible dispensing system.
8. Plan replenishment
Bulk storage changes how lubricant is ordered plus received.
Consider:
► Supplier delivery volume
► Delivery frequency
► Tank remaining capacity
► Product identification
► Delivery access
► Workshop receiving procedure
► Contamination control
Never accept a bulk delivery into the wrong tank.
Expert Tips for Bulk Oil Storage
Bulk storage should make lubricant management more controlled rather than simply larger.
► Label every tank clearly. Include lubricant type plus grade where appropriate.
► Keep fill points identified. Prevent the wrong oil entering the storage system.
► Inspect tanks regularly. Look for visible damage, leakage plus abnormal condition.
► Keep dispensing equipment clean. Pumps, hoses plus guns form part of the lubricant
cleanliness chain.
► Monitor inventory. Avoid unexpected shortages during high servicing demand.
► Control access. Make sure technicians understand which tank supplies each lubricant.
► Keep transfer equipment dedicated. Avoid mixing unrelated fluids through shared equipment.
► Inspect hose reels. Leakage or damaged hose can compromise the dispensing system.
► Check control guns. Metering plus shut-off functions should operate correctly.
► Review pump performance. Reduced flow can indicate restriction, wear or another system
Issue.
► Plan tank maintenance. Include bulk storage in the workshop’s preventative-maintenance
Program.
► Document fluid procedures. New technicians should be able to identify the correct oil path without relying on memory.
For fluid-identification plus workshop chemical knowledge, How to Read a Safety Data Sheet - A Quick Guide for Workshop Operators provides relevant supporting guidance.
Industrial Shed’s On-Site & Workshop Services also provides a practical service pathway for larger workshop equipment requirements.
400L vs 750L vs 1000L vs 1500L Double Skinned Tanks
Tank size should follow actual lubricant turnover.
400L Double Skinned Tank
Useful for:
► Smaller workshops
► One high-use lubricant
► Lower monthly consumption
► Sites moving beyond individual drums
750L Double Skinned Tank
Useful for:
► Mid-sized workshops
► Fleet maintenance
► Agricultural servicing
► Medium-volume industrial use
1000L Double Skinned Tank
Useful for:
► Large workshops
► Fleet depots
► Industrial maintenance
► Centralised oil rooms
► High servicing frequency
1500L Double Skinned Tank
Useful for:
► Large fleet operations
► Manufacturing plants
► Heavy-equipment workshops
► Major industrial maintenance programs
► High lubricant throughput
Bigger capacity is not automatically more efficient.
Match tank size to consumption, delivery cycle plus available space.
Double Skinned Tanks vs 205L Drums
Both can store workshop lubricants but they suit different scales.
205L drums can remain practical where:
► Oil consumption is moderate
► Multiple lubricant types are stocked in smaller quantities
► Portability matters
► Workshop infrastructure is limited
Double skinned tanks become more attractive where:
► One lubricant is consumed regularly
► Bulk purchasing suits the business
► Centralised dispensing is required
► Multiple service bays rely on the same oil supply
► Pumps plus reels form part of the fluid system
► Workshop fluid management needs greater structure
The decision should follow lubricant volume plus workflow rather than assuming bulk storage is automatically better.
Building a Complete Oil Dispensing System
A double-skinned tank can serve as the starting point for a complete oil-distribution system.
A typical configuration can look like:
Double skinned tank → oil pump → hose reel → meter or control gun → machine
Depending on the workshop, the system can also include:
► Filter
► Regulator
► Isolation valve
► Inline meter
► Multiple hose reels
► Multiple dispensing points
► Wall or frame mounting
► Fluid identification
Each component should be compatible with the lubricant plus system pressure.
Metered Oil Dispensing From Bulk Tanks
Metering becomes particularly useful where oil is dispensed repeatedly from a shared bulk supply.
Benefits can include:
► Service quantity visibility
► Fleet lubricant tracking
► Workshop usage records
► Easier stock reconciliation
► Reduced reliance on estimation
► Repeatable known-volume servicing
Metered dispensing does not replace final machine-level checks.
Technicians should still follow the equipment manufacturer’s servicing procedure.
Bulk Lubricant Storage & Contamination Control
Bulk storage increases the importance of lubricant cleanliness.
Contamination introduced at the tank can move through the entire distribution system.
Good practice includes:
► Clean fill connections
► Clearly identified delivery points
► Dedicated pumps
► Clean hoses
► Protected nozzles
► Regular filter inspection where fitted
► Controlled tank access
► Documented lubricant identification
► Appropriate receiving procedures
Never assume oil remains clean simply because it arrived in bulk.
The storage plus dispensing system needs to protect that lubricant through to the machine.
Double Wall Storage & Workshop Planning
The double-wall architecture is a core feature of Macnaught’s OTSB tank range.
The workshop should still plan the installation around:
► Tank capacity
► Location
► Access
► Pump setup
► Hose routing
► Maintenance clearance
► Fluid deliveries
► Workshop movement
► Local site requirements
► Applicable workplace procedures
Installation requirements can vary according to tank use, facility design plus local regulatory obligations.
Confirm applicable requirements before commissioning a bulk fluid-storage system.
Tank Packages With Pumps, Reels & Guns
Macnaught offers double-wall tanks in various package configurations.
A tank package can be useful where a business wants an integrated system rather than sourcing every fluid-handling component separately.
Depending on the selected configuration, packages can combine:
► Tank
► Oil pump
► Hose reel
► Delivery hose
► Oil gun
► Metered gu
► Supporting fittings
This can simplify system matching where the package has already been designed around compatible components.
Always confirm the exact package contents before ordering.
For broader workshop preparation before major servicing periods, Spring Jobsite Prep Getting Your Gear Ready provides useful supporting reading.