► ICCONS® | Safety Load Strips

Reliable .27 Calibre Charges for Powder-Actuated Fastening Running an ICCONS® PX375 across repetitive concrete or steel fixing work? ICCONS® | Safety Load Strips provide the .27 calibre strip-load format used with compatible powder-actuated fastening equipment, supporting efficient direct fixing across suitable construction applications. The load strip, tool, drive pin &...

Reliable .27 Calibre Charges for Powder-Actuated Fastening

Running an ICCONS® PX375 across repetitive concrete or steel fixing work? ICCONS® | Safety Load Strips provide the .27 calibre strip-load format used with compatible powder-actuated fastening equipment, supporting efficient direct fixing across suitable construction applications.

The load strip, tool, drive pin & base material need to work as one fastening setup. ICCONS® identifies its PX Load Strip as a .27 calibre load, while the PX375 semi-automatic low-velocity tool accepts 10-charge .27 calibre safety strips.

For the wider fixing setup, Specialty Fasteners & Fixings provides related fastening options, Concrete Cutting & Drilling Tools supports alternative concrete installation methods & Power Tools covers equipment used across broader construction work.

What Are ICCONS® Safety Load Strips?

Safety Load Strips are power charges used within compatible powder-actuated fastening equipment. The ICCONS® PX Load Strip – .27 Calibre Loads is designed to supply the driving energy required by the corresponding direct-fixing system.

The strip format provides a sequence of charges for compatible semi-automatic operation.

Key system details include:

► Load: ICCONS® PX Load Strip – .27 calibre
► Format: Strip-based powder-actuated charge
► Compatible ICCONS® tool: PX375 Powder Actuated Tool
► PX375 capacity: 10-charge .27 calibre safety strip
► Associated consumables: PX drive pins & compatible pre-assembled pin systems
► Typical substrates: Concrete & steel where permitted by the selected fastening system
► Typical work: Base plates, drywall track, formwork, barriers, clips & other compatible direct-fixing applications

The charge provides the driving energy while the drive pin forms the actual connection. Both components need to correspond with the tool, substrate & material being fixed.

Why Choose ICCONS® Safety Load Strips?

Support Repetitive PX375 Installation

Repeated direct fixing benefits from a consumable format designed around the tool. The ICCONS® PX375 accepts a 10-charge .27 calibre safety strip, allowing compatible fastening work to progress through sequential fixing points.

This arrangement is particularly useful across repeated base-plate, track, formwork & fixture installation.

Match the Charge to the Tool

Powder-actuated loads should be identified by more than their physical appearance. Calibre, strip format, tool compatibility, fastener & substrate all form part of the selection process.

Keeping ICCONS® PX charges with their corresponding equipment also makes replacement consumables easier to identify.

Direct Fixing into Compatible Concrete & Steel

Some construction connections can be completed using direct fastening rather than a separately drilled fixing method. ICCONS® PX drive pins support numerous compatible concrete & steel applications when installed using the appropriate PX equipment.

For a broader understanding of fastener selection across different substrates, see the Fastener Guide Bolts Screws Anchors.

Keep Different Charge Formats Clearly Identified

Similar consumables can belong to very different powder-actuated systems. ICCONS® offers .27 calibre strips alongside other PX charge formats, making clear product identification important when several systems are stored or transported together.

Tools Storage & Organization can support separation of tools & conventional job-specific consumables.

Common Applications

Timber Base Plates to Concrete

Securing a timber frame often begins at the connection between the base plate & slab. ICCONS® identifies compatible PX drive pins for timber-to-concrete base-plate fastening using suitable powder-actuated equipment.

Confirm the required fixing positions & applicable fastening arrangement before installation begins.

Drywall Track to Concrete

Long partition runs can involve a substantial number of repeated fixing points. The PX375 is suited to applicable drywall-framing work over concrete, with the .27 calibre safety strip supplying the compatible charge format.

Where other parts of the framing system require conventional fasteners, Screws & Anchors provides additional options.

Formwork Setup

Temporary construction work still requires the fastener to suit the material beneath it. ICCONS® identifies formwork among the applications for compatible PX drive-pin systems.

Choose the drive pin according to the actual fixture & substrate rather than assuming one pin arrangement suits every formwork connection.

Safety Barrier Installation

Temporary barriers need secure attachment appropriate to the supporting material. Compatible ICCONS® PX drive pins can form part of safety-barrier installation, with the load strip providing the driving charge for the specified powder-actuated equipment.

The completed barrier should still meet applicable site & installation requirements.

Steel Track & Fixtures to Concrete

Direct fixing can simplify repetitive installation of suitable thin-steel components to concrete. ICCONS® PX drive-pin systems include options for compatible steel track & fixture applications.

Pre-assembled washered or top-hat configurations may also be available for particular fastening requirements.

Ceiling, Partitioning & Wire-Hanging Fixtures

Pre-assembled fasteners can reduce separate component handling across repetitive installation work. ICCONS® offers PX drive pins with applicable angle-clip assemblies for compatible ceiling, partitioning & wire-hanging applications.

Where accurate fixing lines matter across longer runs, Measuring & Leveling Tools can assist with positioning before installation.

Insulation Fixing

Insulation panels can require a broader bearing surface than a standard pin head provides. ICCONS® offers dedicated PX insulation fasteners & washered drive-pin assemblies for compatible ceiling, wall & façade applications.

Select the fastener around the attached material & substrate rather than using the load strip alone to determine the connection.

Product Selection Guide

Before selecting powder-actuated consumables, confirm the tool, fastener, fixture & substrate as one complete setup.

Selection Point

What to Confirm

Why It Matters

Charge format

.27 calibre strip

Must correspond with compatible equipment

Tool

ICCONS® PX375 or specified compatible system

Determines the accepted load format

Fastener

PX drive pin or approved assembly

Must suit the fixture & substrate

Base material

Concrete or steel as applicable

Influences the fastening arrangement

Fixture

Timber, steel track, clip, washered component or other suitable material

Determines fastener style

Pin length

Match to fixture & substrate requirements

Supports correct installation

Tool condition

Clean, maintained & functioning correctly

Supports reliable operation

Operating procedure

Current manufacturer instructions

Guides correct tool & consumable use

.27 Calibre Strip, .25 Calibre Disk or .22 Calibre Single Shot?

These charge formats belong to different equipment arrangements & should not be treated as interchangeable. ICCONS® identifies .27 calibre load strips, .25 calibre load disks & .22 calibre single-shot loads within its PX consumable range.

Use the charge format specified for the powder-actuated tool being operated.

Which ICCONS® Tool Uses the .27 Calibre Strip?

The PX375 is a key tool associated with this charge format. ICCONS® specifies the PX375 as a .27 calibre semi-automatic low-velocity tool accepting a 10-charge safety strip.

Its adjustable power control allows penetration to be set according to the applicable fastening conditions & manufacturer instructions.

Does the Load Determine Drive-Pin Length?

No. The connection determines the fastener dimensions. ICCONS® PX drive pins are available in different lengths & assemblies for different applications.

Select the pin according to the fixture, substrate & documented fastening requirements.

Standard Pin or Pre-Assembled Fixing?

The material being attached can determine whether additional components are needed around the pin. Alongside standard PX drive pins, ICCONS® provides applicable configurations incorporating angle clips, top hats, washers & insulation components.

For connections better suited to conventional mechanical anchoring, Anchors & Wall Plugs provides alternative fixing options.

Expert Tips

Identify Replacement Loads from the Tool

Tool identification provides a reliable starting point when replenishing powder-actuated consumables. Record the equipment model & original ICCONS® load details so replacement charges can be matched correctly.

Retain Original Load Packaging

Clear calibre & product identification is important when handling powder-actuated consumables. Keep loads in their original packaging & follow the manufacturer's handling, storage & transport instructions.

Select the Drive Pin Before Adjusting the Tool

Power adjustment cannot compensate for a fastener that doesn't suit the connection. Establish the fixture, substrate & required PX pin first, then configure the tool according to current ICCONS® instructions.

Check the Base Material

Concrete & steel conditions can vary considerably across a project. Confirm that the actual substrate is suitable for the selected direct-fixing method before beginning repetitive installation.

For further practical context around selecting fasteners according to the connection, read Why Good Fasteners Matter More Than the Tool You Drive Them With.

Maintain the PX375

Reliable operation depends on the condition of the powder-actuated tool as well as the consumables loaded into it. Inspect, clean & maintain the PX375 according to the manufacturer's instructions.

For relevant equipment servicing enquiries, Power Tool Repairs & Diagnostics can assist with tool assessment & repair requirements.

Separate Loads from General Hardware

Powder loads require different handling from ordinary screws, pins or loose fasteners. Keep charge strips clearly identified & stored according to manufacturer instructions, workplace procedures & applicable requirements.

Follow the Complete Operating Procedure

Previous experience with another powder-actuated tool doesn't replace the instructions for the equipment currently in use. Follow current ICCONS® guidance for the PX375, selected load, drive pin, substrate & intended application.

For additional guidance on recognising equipment issues before they interrupt work, see 7 Signs Your Power Tool Needs a Service Before It Fails On Site.

Why Buy ICCONS® Safety Load Strips From Industrial Shed?

Correct identification matters when replenishing powder-actuated consumables. Industrial Shed supports construction crews, fit-out trades, formworkers & maintenance teams sourcing ICCONS® loads, fasteners & related equipment for compatible direct-fixing work.

For conventional fasteners & smaller supporting components carried alongside the PX system, Small Parts Organisers can help keep different hardware types separated during transport & storage.

Larger projects benefit from checking expected fixing quantities before crews begin repetitive installation. Confirm the tool, load format, drive-pin requirement & approximate number of fixing points when planning consumables.

For qualifying stocked loads & related consumables required around current project schedules, review Same day dispatch for current dispatch arrangements.

Start with the Tool. Match the Load. Confirm the Fixing.

Every component should be identified before the first direct fixing is made. Confirm the powder-actuated tool, .27 calibre strip, compatible PX drive pin, fixture & substrate before loading the equipment.

Clear product identification helps keep repeated fastening work consistent from one fixing point to the next. Maintain separation between charge formats & use the current ICCONS® operating instructions throughout installation.

For practical preparation before equipment & consumables are committed to the next project, see Spring Jobsite Prep Getting Your Gear Ready.

 Confirm the ICCONS® PX tool, .27 calibre Safety Load Strip, compatible drive pin & substrate before direct fastening begins.

Frequently Asked Questions

What are ICCONS® Safety Load Strips used for?

They are .27 calibre powder-actuated charges used with compatible direct-fixing equipment, including the ICCONS® PX375.

How many charges are in a PX375 safety strip?

The ICCONS® PX375 accepts a 10-charge .27 calibre safety strip.

Can .27 calibre strips replace ICCONS® .25 calibre disks?

No. .27 calibre strips, .25 calibre disks & .22 calibre single-shot loads are separate charge formats. Use the type specified for the particular tool.

Do ICCONS® Safety Load Strips include drive pins?

No. The load strip supplies the charge. PX drive pins or compatible pre-assembled fasteners are separate components selected according to the fixing application.

Can the ICCONS® PX system be used with concrete & steel?

Applicable PX drive pins can be used for compatible fastening into concrete & steel. The correct setup depends on the substrate, fixture, fastener & equipment.

What types of work can the PX375 handle?

Applicable work includes frame base plates, timber to concrete or steel, drywall framing, formwork, safety barriers & other compatible direct-fixing applications.

Brands

► ICCONS® | Safety Load Strips

Reliable .27 Calibre Charges for Powder-Actuated Fastening

Running an ICCONS® PX375 across repetitive concrete or steel fixing work? ICCONS® | Safety Load Strips provide the .27 calibre strip-load format used with compatible powder-actuated fastening equipment, supporting efficient direct fixing across suitable construction applications.

The load strip, tool, drive pin & base material need to work as one fastening setup. ICCONS® identifies its PX Load Strip as a .27 calibre load, while the PX375 semi-automatic low-velocity tool accepts 10-charge .27 calibre safety strips.

For the wider fixing setup, Specialty Fasteners & Fixings provides related fastening options, Concrete Cutting & Drilling Tools supports alternative concrete installation methods & Power Tools covers equipment used across broader construction work.

What Are ICCONS® Safety Load Strips?

Safety Load Strips are power charges used within compatible powder-actuated fastening equipment. The ICCONS® PX Load Strip – .27 Calibre Loads is designed to supply the driving energy required by the corresponding direct-fixing system.

The strip format provides a sequence of charges for compatible semi-automatic operation.

Key system details include:

► Load: ICCONS® PX Load Strip – .27 calibre
► Format: Strip-based powder-actuated charge
► Compatible ICCONS® tool: PX375 Powder Actuated Tool
► PX375 capacity: 10-charge .27 calibre safety strip
► Associated consumables: PX drive pins & compatible pre-assembled pin systems
► Typical substrates: Concrete & steel where permitted by the selected fastening system
► Typical work: Base plates, drywall track, formwork, barriers, clips & other compatible direct-fixing applications

The charge provides the driving energy while the drive pin forms the actual connection. Both components need to correspond with the tool, substrate & material being fixed.

Why Choose ICCONS® Safety Load Strips?

Support Repetitive PX375 Installation

Repeated direct fixing benefits from a consumable format designed around the tool. The ICCONS® PX375 accepts a 10-charge .27 calibre safety strip, allowing compatible fastening work to progress through sequential fixing points.

This arrangement is particularly useful across repeated base-plate, track, formwork & fixture installation.

Match the Charge to the Tool

Powder-actuated loads should be identified by more than their physical appearance. Calibre, strip format, tool compatibility, fastener & substrate all form part of the selection process.

Keeping ICCONS® PX charges with their corresponding equipment also makes replacement consumables easier to identify.

Direct Fixing into Compatible Concrete & Steel

Some construction connections can be completed using direct fastening rather than a separately drilled fixing method. ICCONS® PX drive pins support numerous compatible concrete & steel applications when installed using the appropriate PX equipment.

For a broader understanding of fastener selection across different substrates, see the Fastener Guide Bolts Screws Anchors.

Keep Different Charge Formats Clearly Identified

Similar consumables can belong to very different powder-actuated systems. ICCONS® offers .27 calibre strips alongside other PX charge formats, making clear product identification important when several systems are stored or transported together.

Tools Storage & Organization can support separation of tools & conventional job-specific consumables.

Common Applications

Timber Base Plates to Concrete

Securing a timber frame often begins at the connection between the base plate & slab. ICCONS® identifies compatible PX drive pins for timber-to-concrete base-plate fastening using suitable powder-actuated equipment.

Confirm the required fixing positions & applicable fastening arrangement before installation begins.

Drywall Track to Concrete

Long partition runs can involve a substantial number of repeated fixing points. The PX375 is suited to applicable drywall-framing work over concrete, with the .27 calibre safety strip supplying the compatible charge format.

Where other parts of the framing system require conventional fasteners, Screws & Anchors provides additional options.

Formwork Setup

Temporary construction work still requires the fastener to suit the material beneath it. ICCONS® identifies formwork among the applications for compatible PX drive-pin systems.

Choose the drive pin according to the actual fixture & substrate rather than assuming one pin arrangement suits every formwork connection.

Safety Barrier Installation

Temporary barriers need secure attachment appropriate to the supporting material. Compatible ICCONS® PX drive pins can form part of safety-barrier installation, with the load strip providing the driving charge for the specified powder-actuated equipment.

The completed barrier should still meet applicable site & installation requirements.

Steel Track & Fixtures to Concrete

Direct fixing can simplify repetitive installation of suitable thin-steel components to concrete. ICCONS® PX drive-pin systems include options for compatible steel track & fixture applications.

Pre-assembled washered or top-hat configurations may also be available for particular fastening requirements.

Ceiling, Partitioning & Wire-Hanging Fixtures

Pre-assembled fasteners can reduce separate component handling across repetitive installation work. ICCONS® offers PX drive pins with applicable angle-clip assemblies for compatible ceiling, partitioning & wire-hanging applications.

Where accurate fixing lines matter across longer runs, Measuring & Leveling Tools can assist with positioning before installation.

Insulation Fixing

Insulation panels can require a broader bearing surface than a standard pin head provides. ICCONS® offers dedicated PX insulation fasteners & washered drive-pin assemblies for compatible ceiling, wall & façade applications.

Select the fastener around the attached material & substrate rather than using the load strip alone to determine the connection.

Product Selection Guide

Before selecting powder-actuated consumables, confirm the tool, fastener, fixture & substrate as one complete setup.

Selection Point

What to Confirm

Why It Matters

Charge format

.27 calibre strip

Must correspond with compatible equipment

Tool

ICCONS® PX375 or specified compatible system

Determines the accepted load format

Fastener

PX drive pin or approved assembly

Must suit the fixture & substrate

Base material

Concrete or steel as applicable

Influences the fastening arrangement

Fixture

Timber, steel track, clip, washered component or other suitable material

Determines fastener style

Pin length

Match to fixture & substrate requirements

Supports correct installation

Tool condition

Clean, maintained & functioning correctly

Supports reliable operation

Operating procedure

Current manufacturer instructions

Guides correct tool & consumable use

.27 Calibre Strip, .25 Calibre Disk or .22 Calibre Single Shot?

These charge formats belong to different equipment arrangements & should not be treated as interchangeable. ICCONS® identifies .27 calibre load strips, .25 calibre load disks & .22 calibre single-shot loads within its PX consumable range.

Use the charge format specified for the powder-actuated tool being operated.

Which ICCONS® Tool Uses the .27 Calibre Strip?

The PX375 is a key tool associated with this charge format. ICCONS® specifies the PX375 as a .27 calibre semi-automatic low-velocity tool accepting a 10-charge safety strip.

Its adjustable power control allows penetration to be set according to the applicable fastening conditions & manufacturer instructions.

Does the Load Determine Drive-Pin Length?

No. The connection determines the fastener dimensions. ICCONS® PX drive pins are available in different lengths & assemblies for different applications.

Select the pin according to the fixture, substrate & documented fastening requirements.

Standard Pin or Pre-Assembled Fixing?

The material being attached can determine whether additional components are needed around the pin. Alongside standard PX drive pins, ICCONS® provides applicable configurations incorporating angle clips, top hats, washers & insulation components.

For connections better suited to conventional mechanical anchoring, Anchors & Wall Plugs provides alternative fixing options.

Expert Tips

Identify Replacement Loads from the Tool

Tool identification provides a reliable starting point when replenishing powder-actuated consumables. Record the equipment model & original ICCONS® load details so replacement charges can be matched correctly.

Retain Original Load Packaging

Clear calibre & product identification is important when handling powder-actuated consumables. Keep loads in their original packaging & follow the manufacturer's handling, storage & transport instructions.

Select the Drive Pin Before Adjusting the Tool

Power adjustment cannot compensate for a fastener that doesn't suit the connection. Establish the fixture, substrate & required PX pin first, then configure the tool according to current ICCONS® instructions.

Check the Base Material

Concrete & steel conditions can vary considerably across a project. Confirm that the actual substrate is suitable for the selected direct-fixing method before beginning repetitive installation.

For further practical context around selecting fasteners according to the connection, read Why Good Fasteners Matter More Than the Tool You Drive Them With.

Maintain the PX375

Reliable operation depends on the condition of the powder-actuated tool as well as the consumables loaded into it. Inspect, clean & maintain the PX375 according to the manufacturer's instructions.

For relevant equipment servicing enquiries, Power Tool Repairs & Diagnostics can assist with tool assessment & repair requirements.

Separate Loads from General Hardware

Powder loads require different handling from ordinary screws, pins or loose fasteners. Keep charge strips clearly identified & stored according to manufacturer instructions, workplace procedures & applicable requirements.

Follow the Complete Operating Procedure

Previous experience with another powder-actuated tool doesn't replace the instructions for the equipment currently in use. Follow current ICCONS® guidance for the PX375, selected load, drive pin, substrate & intended application.

For additional guidance on recognising equipment issues before they interrupt work, see 7 Signs Your Power Tool Needs a Service Before It Fails On Site.