► ICCONS® | Packers

Set Accurate Gaps Around Frames, Machinery & Construction Fixings Small differences in level, clearance & position can affect how a frame, machine or construction component sits before it is finally secured. ICCONS® | Packers provide colour-coded plastic packing shims for controlled spacing during door & window installation, machinery positioning &...

Set Accurate Gaps Around Frames, Machinery & Construction Fixings

Small differences in level, clearance & position can affect how a frame, machine or construction component sits before it is finally secured. ICCONS® | Packers provide colour-coded plastic packing shims for controlled spacing during door & window installation, machinery positioning & other construction work where packing is required.

Their horseshoe profile allows the shim to be positioned around starter bars, locating bolts, pins & similar obstructions rather than requiring the fixing to be removed first. Available across 75 mm & 90 mm formats, the range gives builders, installers, fabricators & maintenance crews a practical way to select packing thickness during set-out.

Where the surrounding assembly also requires fixing hardware, browse  Anchor Bolts,  Structural Fasteners & Bolts or  Measuring & Layout Tools for related installation requirements.

ICCONS packing shims are designed around practical site selection:

► Colour-coded thickness identification
► Plastic construction
► Horseshoe profile
► 75 mm & 90 mm formats
► Individual thickness options
► Mixed tubs available within the documented range
► Suitable for packing beneath panels, machinery, doors & window frames
► Applications across residential, commercial & civil work

What Are ICCONS® Packers?

Packers are shims placed between components or beneath an item to establish the required separation, position or level before the installation is completed.

Instead of repeatedly adjusting a component by eye, installers can introduce a known packing thickness where correction is required.

Typical situations can include:

► Door frames
► Window frames
► Panels
► Machinery
► Construction components
► Positions interrupted by bolts or pins

ICCONS describes its range as quality plastic packing shims intended for construction work where packing is required.

Their role is straightforward: provide a controlled physical spacer at the required position.

Colour Identifies Thickness Before the Packer Goes In

When several shim sizes are sitting together on a workbench or in a tub, fast identification can save repeated measuring.

ICCONS uses colour coding to distinguish packing thicknesses.

Documented examples within the current range include:

► 1.0 mm – Brown
► 1.5 mm – White
► 2.0 mm – Grey
► 3.0 mm / 3.2 mm – Blue
► 5.0 mm – Red
► 6.4 mm – Green
► 10.0 mm – Black

Not every documented thickness is necessarily offered in every length or package configuration.

Check the required dimensions rather than purchasing by colour alone.

Why the Horseshoe Shape Is Useful?

Many packing positions already contain the very component that makes a conventional rectangular shim awkward to insert.

The ICCONS horseshoe profile is specifically intended to facilitate placement around obstructions such as:

► Starter bars
► Locating bolts
► Pins
► Similar projecting components

The open side allows the shim to approach the packing position laterally.

That can make adjustment practical where removing the existing bolt, bar or locating component would interrupt the installation sequence.

Door Frames Need More Than a Straight-Looking Opening

Packing provides a controlled way to correct the space between a frame & the surrounding structure before fixing is completed.

During door-frame installation, check:

► Frame position
► Plumb
► Opening dimensions
► Packing locations
► Fixing positions
► Required clearances

Use packers where the installation calls for local spacing rather than forcing the frame against an uneven substrate.

The fixing method should then suit the frame, substrate & installation requirements.

Where masonry fixings are part of that work,  Anchors & Wall Plugs provides another relevant hardware pathway.

Window Installation Benefits From Deliberate Packing Points

A window frame can be correctly sized for the opening while still requiring local adjustment during installation.

Packing can assist with establishing the required position before the frame is secured.

Work progressively around the opening while checking:

► Level
► Plumb
► Frame alignment
► Specified clearances
► Fixing locations
► Operation where applicable

Avoid placing shims randomly simply to fill visible gaps.

The position & amount of packing should correspond with the installation being completed.

Machinery Introduces a Different Packing Requirement

Machine placement is not the same task as adjusting a door or window frame.

Before inserting shims beneath machinery, establish what the equipment manufacturer, installer or project documentation requires for:

► Support points
► Levelling
► Base arrangement
► Fixing positions
► Anchoring
► Grouting where applicable

ICCONS lists machinery installation among the applications for its packing shims.

That does not make a general plastic packer a substitute for engineered levelling systems, specified machinery mounts or other purpose-designed supports where those are required.

For machinery secured through concrete fixing points,  Anchor Bolts provides related anchoring hardware.

Select Thickness From the Gap You're Correcting

The useful dimension is the amount of adjustment the installation actually requires.

Measure or establish the required correction before selecting a shim.

Depending on the job, this can involve checking:

► Existing gap
► Desired finished position
► Frame dimensions
► Adjacent surfaces
► Level or plumb
► Required clearance

Suitable  Measuring & Layout Tools can assist when several packing points need to produce a consistent finished position.

A mixed tub can be practical where the required correction varies from one location to another.

75 mm & 90 mm Formats Cover Different Setup Requirements

Thickness is only one dimension worth checking.

ICCONS documents its packing shims in 75 mm & 90 mm formats.

Consider the available space around the packing point, the component being positioned & any bolt, pin or other obstruction passing through the horseshoe opening.

Do not assume that two packers of the same thickness are interchangeable if their overall dimensions differ.

Select the format that suits the physical installation.

Stacking Can Build the Required Adjustment

Some gaps will not correspond neatly with a single available shim thickness.

Where the installation permits multiple packers, combining suitable thicknesses can establish the required total spacing.

For example, the selection process should start with the required correction rather than simply adding packers until the component appears close enough.

Keep the packing arrangement:

► Stable
► Properly positioned
► Appropriate to the installation
► Clear of unwanted interference
► Consistent with project requirements

Do not make assumptions about allowable loads or structural performance simply because several plastic shims can physically be stacked together.

Check Position Again Before Tightening the Fixings

Packing changes where the component sits, while tightening can change how the complete assembly behaves.

Before final fastening:

► Recheck level
► Confirm plumb where relevant
► Verify alignment
► Inspect shim position
► Confirm fixing engagement
► Check required clearances

Where bolts form part of the assembly, Bolts & Fasteners provides a related hardware range.

The Fastener Guide Bolts Screws Anchors also explains broader distinctions between common fixing families.

Don't Assign a Structural Rating the Manufacturer Hasn't Given

A plastic shim can provide useful spacing without automatically becoming a rated structural component.

Avoid unsupported assumptions about:

► Maximum load
► Compression capacity
► Long-term structural loading
► Fire performance
► Temperature resistance
► Chemical resistance
► Permanent structural suitability

Where a project requires packers or shims with defined engineering properties, use products supported by the required technical documentation.

The installation specification takes precedence over convenience.

Starter Bars & Locating Bolts Suit the Open Profile

The horseshoe geometry becomes particularly useful when packing must be introduced around an existing projection.

Rather than feeding a closed shim over the end of a long bar or removing a locating bolt, the packer can approach from the side where the assembly permits.

Before placement:

► Check required thickness
► Clear debris from the packing point
► Confirm the packer can sit correctly
► Keep the obstruction within the open section
► Recheck component position afterwards

This is a practical distinction between horseshoe packing shims & simple flat spacer material.

Keep Packing Surfaces Free From Site Debris

A measured shim thickness cannot provide predictable spacing if grit, concrete fragments or other material is trapped underneath it.

Before inserting the packer:

► Inspect the contact area
► Remove loose debris
► Check for projections
► Confirm the shim sits properly
► Recheck the resulting position

Preparation becomes particularly important where several points are being packed to establish a common level.

For broader site-readiness practices, Spring Jobsite Prep Getting Your Gear Ready covers preparation of tools & consumables before demanding work periods.

Mixed Tubs Suit Installations With Variable Gaps

Renovation, fit-out & machinery work can present several different corrections within the same job.

ICCONS documents mixed tubs in both 75 mm & 90 mm packer formats.

A mixed selection can reduce the need to predict one thickness for every position before work begins.

Keep the colours separated or readily visible so installers can identify the required size without turning the tub into an unorganised mix of loose shims.

Where repeat work consistently uses the same thickness, dedicated packs may be more practical.

Packers Should Support the Installation Sequence

The best time to correct position is before the adjoining fixings have been fully secured.

A practical sequence can involve:

► Position the component
► Measure the required adjustment
► Select the packer thickness
► Insert at the required location
► Recheck alignment
► Complete the specified fixing process

If tightening changes the position, reassess the setup rather than assuming the original packer arrangement remains correct.

For a broader look at why the small components around a fixing matter, read Why Good Fasteners Matter More Than the Tool You Drive Them With.

Keep the Colour System Useful in the Vehicle & Workshop

Colour coding loses much of its advantage when every thickness is thrown loose into the same container.

For crews carrying several sizes, organise stock by:

► Thickness
► Colour
► 75 mm or 90 mm format
► Individual packs or mixed tubs

That makes replenishment easier & reduces the chance of an installer selecting a shim from appearance alone without confirming its size.

Packers are small consumables but running out of the required thickness can interrupt an otherwise straightforward installation.

Why Source ICCONS® Packers Through Industrial Shed?

Packing shims tend to be needed at the exact point a frame, panel or machine is being positioned, making the right sizes useful additions to the installation consumables kept close to the work.

Industrial Shed supplies construction fixings, measuring equipment, hand tools & associated site consumables for builders, installers, maintenance teams & contractors across Australia.

For crews maintaining recurring consumable requirements across projects, on -site & workshop Services provides a pathway for jobsite & workshop restocking support.

Need to confirm the packer format required for an upcoming order? Contact Us with the thickness, 75 mm or 90 mm preference & approximate quantity required.

Get the Position Right Before the Fixings Take Over

Packers do their work during the small adjustment window between placing the component & securing it permanently.

Measure the correction, use the appropriate thickness around the required packing point then check the frame, panel or equipment position again before completing the installation.

A few millimetres of deliberate adjustment at this stage can be far easier to manage than correcting an incorrectly positioned component after the surrounding work is complete.

Keep ICCONS Packers within reach when doors, windows, machinery or construction components need controlled spacing around bolts, pins & other installation points.

Frequently Asked Questions

Why are ICCONS packers horseshoe shaped?

The open profile is designed to facilitate shim placement around starter bars, locating bolts, pins & similar obstructions. This allows the packer to approach the position from the side where the installation permits.

Which packer thickness does each colour represent?

The documented range includes brown 1.0 mm, white 1.5 mm, grey 2.0 mm, blue 3.0 mm or 3.2 mm, red 5.0 mm, green 6.4 mm & black 10.0 mm options. Check the actual product dimensions because availability varies by format.

Are ICCONS packing shims available in more than one length?

Yes. ICCONS documents 75 mm & 90 mm packing shims within the range.

Would these be suitable while installing a window or door frame?

Door & window installation are specifically listed applications. The number, thickness & position of packers should suit the particular frame system & installation requirements.

Can I use ICCONS packers beneath machinery?

Machinery installation is a documented application. Where the equipment requires engineered mounts, specified shims, grout or another support system, follow those requirements rather than substituting general packing shims.

When would a mixed tub be useful?

Mixed tubs suit jobs where the required adjustment varies between packing positions or where installers regularly encounter several gap sizes. ICCONS documents mixed tubs in 75 mm & 90 mm formats.

Brands

► ICCONS® | Packers

Set Accurate Gaps Around Frames, Machinery & Construction Fixings

Small differences in level, clearance & position can affect how a frame, machine or construction component sits before it is finally secured. ICCONS® | Packers provide colour-coded plastic packing shims for controlled spacing during door & window installation, machinery positioning & other construction work where packing is required.

Their horseshoe profile allows the shim to be positioned around starter bars, locating bolts, pins & similar obstructions rather than requiring the fixing to be removed first. Available across 75 mm & 90 mm formats, the range gives builders, installers, fabricators & maintenance crews a practical way to select packing thickness during set-out.

Where the surrounding assembly also requires fixing hardware, browse  Anchor Bolts,  Structural Fasteners & Bolts or  Measuring & Layout Tools for related installation requirements.

ICCONS packing shims are designed around practical site selection:

► Colour-coded thickness identification
► Plastic construction
► Horseshoe profile
► 75 mm & 90 mm formats
► Individual thickness options
► Mixed tubs available within the documented range
► Suitable for packing beneath panels, machinery, doors & window frames
► Applications across residential, commercial & civil work

What Are ICCONS® Packers?

Packers are shims placed between components or beneath an item to establish the required separation, position or level before the installation is completed.

Instead of repeatedly adjusting a component by eye, installers can introduce a known packing thickness where correction is required.

Typical situations can include:

► Door frames
► Window frames
► Panels
► Machinery
► Construction components
► Positions interrupted by bolts or pins

ICCONS describes its range as quality plastic packing shims intended for construction work where packing is required.

Their role is straightforward: provide a controlled physical spacer at the required position.

Colour Identifies Thickness Before the Packer Goes In

When several shim sizes are sitting together on a workbench or in a tub, fast identification can save repeated measuring.

ICCONS uses colour coding to distinguish packing thicknesses.

Documented examples within the current range include:

► 1.0 mm – Brown
► 1.5 mm – White
► 2.0 mm – Grey
► 3.0 mm / 3.2 mm – Blue
► 5.0 mm – Red
► 6.4 mm – Green
► 10.0 mm – Black

Not every documented thickness is necessarily offered in every length or package configuration.

Check the required dimensions rather than purchasing by colour alone.

Why the Horseshoe Shape Is Useful?

Many packing positions already contain the very component that makes a conventional rectangular shim awkward to insert.

The ICCONS horseshoe profile is specifically intended to facilitate placement around obstructions such as:

► Starter bars
► Locating bolts
► Pins
► Similar projecting components

The open side allows the shim to approach the packing position laterally.

That can make adjustment practical where removing the existing bolt, bar or locating component would interrupt the installation sequence.

Door Frames Need More Than a Straight-Looking Opening

Packing provides a controlled way to correct the space between a frame & the surrounding structure before fixing is completed.

During door-frame installation, check:

► Frame position
► Plumb
► Opening dimensions
► Packing locations
► Fixing positions
► Required clearances

Use packers where the installation calls for local spacing rather than forcing the frame against an uneven substrate.

The fixing method should then suit the frame, substrate & installation requirements.

Where masonry fixings are part of that work,  Anchors & Wall Plugs provides another relevant hardware pathway.

Window Installation Benefits From Deliberate Packing Points

A window frame can be correctly sized for the opening while still requiring local adjustment during installation.

Packing can assist with establishing the required position before the frame is secured.

Work progressively around the opening while checking:

► Level
► Plumb
► Frame alignment
► Specified clearances
► Fixing locations
► Operation where applicable

Avoid placing shims randomly simply to fill visible gaps.

The position & amount of packing should correspond with the installation being completed.

Machinery Introduces a Different Packing Requirement

Machine placement is not the same task as adjusting a door or window frame.

Before inserting shims beneath machinery, establish what the equipment manufacturer, installer or project documentation requires for:

► Support points
► Levelling
► Base arrangement
► Fixing positions
► Anchoring
► Grouting where applicable

ICCONS lists machinery installation among the applications for its packing shims.

That does not make a general plastic packer a substitute for engineered levelling systems, specified machinery mounts or other purpose-designed supports where those are required.

For machinery secured through concrete fixing points,  Anchor Bolts provides related anchoring hardware.

Select Thickness From the Gap You're Correcting

The useful dimension is the amount of adjustment the installation actually requires.

Measure or establish the required correction before selecting a shim.

Depending on the job, this can involve checking:

► Existing gap
► Desired finished position
► Frame dimensions
► Adjacent surfaces
► Level or plumb
► Required clearance

Suitable  Measuring & Layout Tools can assist when several packing points need to produce a consistent finished position.

A mixed tub can be practical where the required correction varies from one location to another.

75 mm & 90 mm Formats Cover Different Setup Requirements

Thickness is only one dimension worth checking.

ICCONS documents its packing shims in 75 mm & 90 mm formats.

Consider the available space around the packing point, the component being positioned & any bolt, pin or other obstruction passing through the horseshoe opening.

Do not assume that two packers of the same thickness are interchangeable if their overall dimensions differ.

Select the format that suits the physical installation.

Stacking Can Build the Required Adjustment

Some gaps will not correspond neatly with a single available shim thickness.

Where the installation permits multiple packers, combining suitable thicknesses can establish the required total spacing.

For example, the selection process should start with the required correction rather than simply adding packers until the component appears close enough.

Keep the packing arrangement:

► Stable
► Properly positioned
► Appropriate to the installation
► Clear of unwanted interference
► Consistent with project requirements

Do not make assumptions about allowable loads or structural performance simply because several plastic shims can physically be stacked together.

Check Position Again Before Tightening the Fixings

Packing changes where the component sits, while tightening can change how the complete assembly behaves.

Before final fastening:

► Recheck level
► Confirm plumb where relevant
► Verify alignment
► Inspect shim position
► Confirm fixing engagement
► Check required clearances

Where bolts form part of the assembly, Bolts & Fasteners provides a related hardware range.

The Fastener Guide Bolts Screws Anchors also explains broader distinctions between common fixing families.

Don't Assign a Structural Rating the Manufacturer Hasn't Given

A plastic shim can provide useful spacing without automatically becoming a rated structural component.

Avoid unsupported assumptions about:

► Maximum load
► Compression capacity
► Long-term structural loading
► Fire performance
► Temperature resistance
► Chemical resistance
► Permanent structural suitability

Where a project requires packers or shims with defined engineering properties, use products supported by the required technical documentation.

The installation specification takes precedence over convenience.

Starter Bars & Locating Bolts Suit the Open Profile

The horseshoe geometry becomes particularly useful when packing must be introduced around an existing projection.

Rather than feeding a closed shim over the end of a long bar or removing a locating bolt, the packer can approach from the side where the assembly permits.

Before placement:

► Check required thickness
► Clear debris from the packing point
► Confirm the packer can sit correctly
► Keep the obstruction within the open section
► Recheck component position afterwards

This is a practical distinction between horseshoe packing shims & simple flat spacer material.

Keep Packing Surfaces Free From Site Debris

A measured shim thickness cannot provide predictable spacing if grit, concrete fragments or other material is trapped underneath it.

Before inserting the packer:

► Inspect the contact area
► Remove loose debris
► Check for projections
► Confirm the shim sits properly
► Recheck the resulting position

Preparation becomes particularly important where several points are being packed to establish a common level.

For broader site-readiness practices, Spring Jobsite Prep Getting Your Gear Ready covers preparation of tools & consumables before demanding work periods.

Mixed Tubs Suit Installations With Variable Gaps

Renovation, fit-out & machinery work can present several different corrections within the same job.

ICCONS documents mixed tubs in both 75 mm & 90 mm packer formats.

A mixed selection can reduce the need to predict one thickness for every position before work begins.

Keep the colours separated or readily visible so installers can identify the required size without turning the tub into an unorganised mix of loose shims.

Where repeat work consistently uses the same thickness, dedicated packs may be more practical.

Packers Should Support the Installation Sequence

The best time to correct position is before the adjoining fixings have been fully secured.

A practical sequence can involve:

► Position the component
► Measure the required adjustment
► Select the packer thickness
► Insert at the required location
► Recheck alignment
► Complete the specified fixing process

If tightening changes the position, reassess the setup rather than assuming the original packer arrangement remains correct.

For a broader look at why the small components around a fixing matter, read Why Good Fasteners Matter More Than the Tool You Drive Them With.

Keep the Colour System Useful in the Vehicle & Workshop

Colour coding loses much of its advantage when every thickness is thrown loose into the same container.

For crews carrying several sizes, organise stock by:

► Thickness
► Colour
► 75 mm or 90 mm format
► Individual packs or mixed tubs

That makes replenishment easier & reduces the chance of an installer selecting a shim from appearance alone without confirming its size.

Packers are small consumables but running out of the required thickness can interrupt an otherwise straightforward installation.