► ICCONS® | Nylon Frame Fixing Screws

Through-Fix Frames & Profiles Into Concrete & Masonry Frames, profiles & substructures need a fixing that suits both the component in front & the masonry behind it. ICCONS® | Nylon Frame Fixing Screws include the Friulsider FM-X5 family of pre-assembled nylon frame fixings for light-duty, non-structural fastening into compatible concrete...

Through-Fix Frames & Profiles Into Concrete & Masonry

Frames, profiles & substructures need a fixing that suits both the component in front & the masonry behind it. ICCONS® | Nylon Frame Fixing Screws include the Friulsider FM-X5 family of pre-assembled nylon frame fixings for light-duty, non-structural fastening into compatible concrete & masonry base materials.

The FM-X5 combines a Ø10 mm nylon plug with a pre-assembled screw, allowing installation through a positioned fixture into the prepared substrate. Applications include façade & roofing substructures, profiles, insulation fixing & other suitable frame connections. For adjoining installation requirements, compare  Anchors & Wall Plugs,  Concrete Cutting & Drilling Tools or  Drill Accessories.

Across the documented FM-X5 family, available characteristics include:

► Ø10 mm frame-fixing format
► 70 mm minimum anchor embedment across standard documented configurations
► 85 mm to 160 mm documented lengths
► Pre-assembled screw & nylon plug
► Multi-expansion plug geometry
► Countersunk & hex-head configurations
► T40 anti-intrusion option
► FM-X5 TOP higher-performance configuration
► Zinc, galvanised & selected 316 stainless steel options depending on variant
► Applications across compatible concrete & masonry base materials

What Are ICCONS® Nylon Frame Fixing Screws?

FM-X5 frame fixings combine a screw & nylon plug into one pre-assembled fastening system.

A correctly sized hole is prepared through the fixture & into the compatible base material. The fixing passes through the component before the screw is tightened to activate the nylon plug.

This through-fixing method can suit:

► Façade substructures
► Roofing substructures
► Profiles
► Insulation fixing
► Suitable frame installations

Because the fixture can remain in position during installation, set-out can be maintained while the fixing points are prepared.

The exact FM-X5 configuration still needs to correspond with the substrate, fixture thickness, head requirement & project conditions.

Multi-Expansion Geometry Works Across Compatible Masonry Types

Concrete, brick & aerated masonry behave differently when a fixing expands inside the prepared hole.

ICCONS describes FM-X5 with multi-expansion plug geometry, including differentiated expansion towards the plug tip.

Documented compatible base materials across the family include:

► Concrete
► Stone
► Solid brick
► Hollow brick
► Aerated concrete

FM-X5 TOP documentation also identifies solid & hollow block applications.

Use the technical information for the exact FM-X5 variant when confirming suitability for the material being fixed into.

Select Length From Fixture Thickness & Required Embedment

The part of the fixing passing through the frame cannot also provide embedment in the base material.

For standard documented FM-X5 countersunk & hex configurations, the relationship is:

Fixing Length

Minimum Embedment

Maximum Fixture Thickness

85 mm

70 mm

15 mm

100 mm

70 mm

30 mm

115 mm

70 mm

45 mm

135 mm

70 mm

65 mm

160 mm

70 mm

90 mm

Measure the complete material thickness between the fixing head & masonry surface.

Packing or other intermediate materials can increase the distance the fixing needs to pass through before reaching its required embedment.

Countersunk Heads Suit Low-Profile Connections

A countersunk fixing can provide a neater surface where the fixture is designed to receive that head shape.

ICCONS documents FM-X5 countersunk versions with a CSK/TX40 head.

This configuration can be considered where:

► Minimal head projection is preferred
► The fixture accepts a countersunk head
► TX40 installation suits the work
► The selected length provides the required embedment

The head should seat against a compatible surface rather than being forced into material that has not been prepared for a countersunk connection.

For a broader explanation of fixing families & their different installation methods, read the Fastener Guide Bolts Screws Anchors.

Hex-Head FM-X5 Gives the Installer a Different Seating Option

Some profiles & substructures are better suited to a fixing head that remains accessible above the fixture.

Standard FM-X5 hex-head versions retain the documented Ø10 mm hole diameter & 70 mm minimum embedment across their applicable length range while providing a different driving arrangement from the countersunk models.

A hex head may suit work where:

► Head access remains available
► The fixture accepts a projecting head
► The driving arrangement suits installation access
► Countersinking is unnecessary

Choose the head configuration around the actual component rather than treating countersunk & hex versions as interchangeable.

Anti-Intrusion Heads Suit More Exposed Fixing Points

Where the completed fixing remains accessible, resistance to casual removal may become part of product selection.

The FM-X5 Safety configuration uses a T40 anti-intrusion head.

The documented 10 x 85 mm configuration includes:

► Ø10 mm drill diameter
► 70 mm embedment
► 15 mm maximum fixture thickness
► Anti-intrusion/TX40 head
► Zinc or selected 316 stainless steel options

Make sure the corresponding installation drive is available before the fixing work begins.

FM-X5 TOP Is a Separate Higher-Performance Configuration

Variants within the same fixing family can differ in more than head shape.

FM-X5 TOP is documented with:

► PA 6.6 nylon plug
► Multi-expansion geometry
► Anti-rotation barbs
► Pre-assembled screw
► Increased screw diameter
► Asymmetrical thread
► Collared hex head with internal TX40 drive

ICCONS positions FM-X5 TOP as a higher-performance version within the frame-fixing family.

Specify the actual variant required rather than substituting standard countersunk, hex, Safety & TOP configurations solely because their overall dimensions appear similar.

Start With the Documented Ø10 mm Hole

Correct frame fixing begins below the surface with the hole prepared for the plug.

Standard documented FM-X5 countersunk & hex configurations specify a Ø10 mm drill diameter.

Before drilling:

► Identify the exact fixing
► Confirm the base material
► Establish the required depth
► Allow for the nominated embedment
► Keep the drilling position aligned
► Follow the applicable installation instructions

Suitable  Hammer Drills can support masonry drilling where the tool, operating mode & bit suit the material.

Avoid enlarging the hole through unnecessary drill movement.

Through-Fixing Helps Preserve Frame Set-Out

Once a frame or profile has been positioned correctly, unnecessary movement during drilling & fastening can undo careful preparation.

Where the installation permits, a practical sequence is:

► Position the component
► Confirm level, plumb or alignment
► Mark the fixing locations
► Drill through the fixture into the substrate
► Prepare the hole as required
► Insert the pre-assembled fixing
► Tighten with the appropriate drive
► Recheck the finished position

This approach can be particularly useful across repetitive profile & substructure work.

For wider preparation of site tools & consumables, Spring Jobsite Prep Getting Your Gear Ready provides practical jobsite guidance.

Hollow Brick Needs Controlled Drilling

The drill can move from solid material into a cavity within a single hole when working with hollow masonry.

FM-X5 is documented for compatible hollow-brick applications, but hole quality still matters.

Avoid:

► Excessive drilling pressure
► Unnecessary enlargement
► Damaging masonry webs
► Using an incorrect drill diameter
► Assuming every brick behaves identically

Prepare the hole according to the fixing requirements & characteristics of the masonry being drilled.

Aerated Concrete Requires Its Own Installation Consideration

Lower-density base materials should not inherit installation assumptions from ordinary concrete.

ICCONS provides FM-X5 information covering aerated concrete applications.

For this substrate, establish:

► Exact fixing configuration
► Hole-preparation requirements
► Embedment
► Fixture thickness
► Installation method
► Applicable technical information

Do not transfer capacities or installation assumptions between different base materials without supporting documentation.

Match Screw Material & Finish to the Required Configuration

Not every FM-X5 variant uses the same screw material or protective finish.

Depending on configuration, the documented family includes zinc, galvanised & selected 316 stainless steel options.

Before ordering, consider:

► Installation environment
► Required screw material or finish
► Head style
► Fixing length
► Base material
► Project specification

Confirm the exact product rather than assuming that a finish available on one FM-X5 version applies across the complete range.

Set the Frame Before Final Tightening

A frame fixing is there to secure the chosen position, not establish alignment by force.

Before tightening, check:

► Level
► Plumb
► Alignment
► Required clearances
► Packing locations
► Fixing position

If packers sit behind the frame or profile, make sure they remain correctly positioned as the fixing seats.

Movement during tightening should be addressed rather than accepted as part of the installation.

Stop When the Fixing Is Correctly Seated

Additional torque after seating can damage the drive, fixture or fixing arrangement rather than improve it.

Use the drive corresponding with the selected head & follow the applicable installation requirements.

Pay attention to:

► Head seating
► Fixture movement
► Plug rotation
► Drive-recess condition
► Distortion around the fixing point

Unexpected behaviour can indicate an issue with the hole, substrate, fixing selection or installation.

For further practical context, read Why Good Fasteners Matter More Than the Tool You Drive Them With.

Keep Light-Duty Frame Fixing Separate From Structural Anchoring

FM-X5 is documented as a plastic anchor for light-duty, non-structural applications.

That distinction becomes important where the same project also contains structural concrete connections.

Do not substitute a nylon frame fixing for an engineered anchor simply because both products can be installed into concrete or masonry.

Connections involving structural requirements should use the fixing system nominated for that duty.

For adjoining structural hardware, browse  Structural Fasteners & Bolts.

Treat Fire Classification in Its Documented Application

FM-X5 fire-performance information needs to remain connected to the application for which it is documented.

ICCONS technical information identifies an F90 fire resistance classification with the fire rating stated as valid for façade applications only.

Where fire performance forms part of the project requirements, confirm:

► Exact FM-X5 variant
► Base material
► Façade application
► Installation arrangement
► Current supporting documentation

Do not extend a documented façade classification to unrelated installations without supporting information.

Plan Repetitive Frame Fixing Before Drilling Starts

A long run of profiles becomes easier to manage when fixing lengths, head styles & drilling equipment have already been matched to the work.

Before starting repetitive installation, establish:

► Substrate
► Fixture thickness
► FM-X5 length
► Head configuration
► Required finish
► Drill bit
► Driving equipment
► Set-out positions

For associated threaded fastening requirements elsewhere in the assembly, Bolts & Fasteners provides a broader hardware range.

Keeping the fixing configuration consistent with the actual assembly reduces unnecessary changes once installation is underway.

Industrial Shed Support for Frame-Fixing Projects

Getting the frame fixings right is easier when the drilling equipment, drive accessories & adjoining hardware are being considered as part of the same installation.

Industrial Shed supplies concrete & masonry fixings, drilling equipment, hand tools & associated trade hardware for builders, façade contractors, installers & maintenance teams across Australia.

For businesses managing recurring project requirements, Trade support Solutions provides a dedicated pathway for trade customers.

Once the required FM-X5 configuration has been established, Same day dispatch provides current information on order dispatch & delivery.

Secure the Position You've Already Established

The frame should reach the fixing stage with its alignment resolved & the required connection understood.

Measure the fixture thickness, identify the masonry, select the corresponding FM-X5 configuration then prepare the Ø10 mm hole to the applicable requirements. Seat the fixing without using excessive tightening to compensate for poor set-out.

The result is a straightforward through-fixing process built around the actual frame, substrate & installation conditions.

For the next frame-fixing run, have the ICCONS FM-X5 length, head style, finish & installation accessories matched to the assembly before drilling begins.

Frequently Asked Questions

A profile measures 45 mm thick. Which standard FM-X5 length corresponds with that fixture thickness?

The documented standard 10 x 115 mm configuration accommodates up to 45 mm fixture thickness while retaining the stated 70 mm minimum embedment. Confirm the complete installation against the technical information for the selected variant.

Does changing from countersunk to hex head mean changing drill diameter?

Standard documented countersunk & hex FM-X5 configurations both specify a Ø10 mm hole.

Will FM-X5 work in hollow brick as well as concrete?

Compatible hollow brick & concrete are among the documented base materials for the family. Installation requirements & performance can differ by substrate, so use the information applicable to the material being fixed into.

Why would I specify the Safety version instead of a standard head?

The Safety configuration provides a T40 anti-intrusion head where resistance to casual removal at an accessible fixing point is desirable.

Where does FM-X5 stop being the appropriate anchor choice?

Its documented role is light-duty, non-structural frame fixing. A connection carrying structural loads or requiring an engineered anchoring system needs a fixing specified for that responsibility.

Are all FM-X5 screws stainless steel?

No. Available material & finish depend on configuration. The documented family includes zinc, galvanised & selected 316 stainless steel options.

Brands

► ICCONS® | Nylon Frame Fixing Screws

Through-Fix Frames & Profiles Into Concrete & Masonry

Frames, profiles & substructures need a fixing that suits both the component in front & the masonry behind it. ICCONS® | Nylon Frame Fixing Screws include the Friulsider FM-X5 family of pre-assembled nylon frame fixings for light-duty, non-structural fastening into compatible concrete & masonry base materials.

The FM-X5 combines a Ø10 mm nylon plug with a pre-assembled screw, allowing installation through a positioned fixture into the prepared substrate. Applications include façade & roofing substructures, profiles, insulation fixing & other suitable frame connections. For adjoining installation requirements, compare  Anchors & Wall Plugs,  Concrete Cutting & Drilling Tools or  Drill Accessories.

Across the documented FM-X5 family, available characteristics include:

► Ø10 mm frame-fixing format
► 70 mm minimum anchor embedment across standard documented configurations
► 85 mm to 160 mm documented lengths
► Pre-assembled screw & nylon plug
► Multi-expansion plug geometry
► Countersunk & hex-head configurations
► T40 anti-intrusion option
► FM-X5 TOP higher-performance configuration
► Zinc, galvanised & selected 316 stainless steel options depending on variant
► Applications across compatible concrete & masonry base materials

What Are ICCONS® Nylon Frame Fixing Screws?

FM-X5 frame fixings combine a screw & nylon plug into one pre-assembled fastening system.

A correctly sized hole is prepared through the fixture & into the compatible base material. The fixing passes through the component before the screw is tightened to activate the nylon plug.

This through-fixing method can suit:

► Façade substructures
► Roofing substructures
► Profiles
► Insulation fixing
► Suitable frame installations

Because the fixture can remain in position during installation, set-out can be maintained while the fixing points are prepared.

The exact FM-X5 configuration still needs to correspond with the substrate, fixture thickness, head requirement & project conditions.

Multi-Expansion Geometry Works Across Compatible Masonry Types

Concrete, brick & aerated masonry behave differently when a fixing expands inside the prepared hole.

ICCONS describes FM-X5 with multi-expansion plug geometry, including differentiated expansion towards the plug tip.

Documented compatible base materials across the family include:

► Concrete
► Stone
► Solid brick
► Hollow brick
► Aerated concrete

FM-X5 TOP documentation also identifies solid & hollow block applications.

Use the technical information for the exact FM-X5 variant when confirming suitability for the material being fixed into.

Select Length From Fixture Thickness & Required Embedment

The part of the fixing passing through the frame cannot also provide embedment in the base material.

For standard documented FM-X5 countersunk & hex configurations, the relationship is:

Fixing Length

Minimum Embedment

Maximum Fixture Thickness

85 mm

70 mm

15 mm

100 mm

70 mm

30 mm

115 mm

70 mm

45 mm

135 mm

70 mm

65 mm

160 mm

70 mm

90 mm

Measure the complete material thickness between the fixing head & masonry surface.

Packing or other intermediate materials can increase the distance the fixing needs to pass through before reaching its required embedment.

Countersunk Heads Suit Low-Profile Connections

A countersunk fixing can provide a neater surface where the fixture is designed to receive that head shape.

ICCONS documents FM-X5 countersunk versions with a CSK/TX40 head.

This configuration can be considered where:

► Minimal head projection is preferred
► The fixture accepts a countersunk head
► TX40 installation suits the work
► The selected length provides the required embedment

The head should seat against a compatible surface rather than being forced into material that has not been prepared for a countersunk connection.

For a broader explanation of fixing families & their different installation methods, read the Fastener Guide Bolts Screws Anchors.

Hex-Head FM-X5 Gives the Installer a Different Seating Option

Some profiles & substructures are better suited to a fixing head that remains accessible above the fixture.

Standard FM-X5 hex-head versions retain the documented Ø10 mm hole diameter & 70 mm minimum embedment across their applicable length range while providing a different driving arrangement from the countersunk models.

A hex head may suit work where:

► Head access remains available
► The fixture accepts a projecting head
► The driving arrangement suits installation access
► Countersinking is unnecessary

Choose the head configuration around the actual component rather than treating countersunk & hex versions as interchangeable.

Anti-Intrusion Heads Suit More Exposed Fixing Points

Where the completed fixing remains accessible, resistance to casual removal may become part of product selection.

The FM-X5 Safety configuration uses a T40 anti-intrusion head.

The documented 10 x 85 mm configuration includes:

► Ø10 mm drill diameter
► 70 mm embedment
► 15 mm maximum fixture thickness
► Anti-intrusion/TX40 head
► Zinc or selected 316 stainless steel options

Make sure the corresponding installation drive is available before the fixing work begins.

FM-X5 TOP Is a Separate Higher-Performance Configuration

Variants within the same fixing family can differ in more than head shape.

FM-X5 TOP is documented with:

► PA 6.6 nylon plug
► Multi-expansion geometry
► Anti-rotation barbs
► Pre-assembled screw
► Increased screw diameter
► Asymmetrical thread
► Collared hex head with internal TX40 drive

ICCONS positions FM-X5 TOP as a higher-performance version within the frame-fixing family.

Specify the actual variant required rather than substituting standard countersunk, hex, Safety & TOP configurations solely because their overall dimensions appear similar.

Start With the Documented Ø10 mm Hole

Correct frame fixing begins below the surface with the hole prepared for the plug.

Standard documented FM-X5 countersunk & hex configurations specify a Ø10 mm drill diameter.

Before drilling:

► Identify the exact fixing
► Confirm the base material
► Establish the required depth
► Allow for the nominated embedment
► Keep the drilling position aligned
► Follow the applicable installation instructions

Suitable  Hammer Drills can support masonry drilling where the tool, operating mode & bit suit the material.

Avoid enlarging the hole through unnecessary drill movement.

Through-Fixing Helps Preserve Frame Set-Out

Once a frame or profile has been positioned correctly, unnecessary movement during drilling & fastening can undo careful preparation.

Where the installation permits, a practical sequence is:

► Position the component
► Confirm level, plumb or alignment
► Mark the fixing locations
► Drill through the fixture into the substrate
► Prepare the hole as required
► Insert the pre-assembled fixing
► Tighten with the appropriate drive
► Recheck the finished position

This approach can be particularly useful across repetitive profile & substructure work.

For wider preparation of site tools & consumables, Spring Jobsite Prep Getting Your Gear Ready provides practical jobsite guidance.

Hollow Brick Needs Controlled Drilling

The drill can move from solid material into a cavity within a single hole when working with hollow masonry.

FM-X5 is documented for compatible hollow-brick applications, but hole quality still matters.

Avoid:

► Excessive drilling pressure
► Unnecessary enlargement
► Damaging masonry webs
► Using an incorrect drill diameter
► Assuming every brick behaves identically

Prepare the hole according to the fixing requirements & characteristics of the masonry being drilled.

Aerated Concrete Requires Its Own Installation Consideration

Lower-density base materials should not inherit installation assumptions from ordinary concrete.

ICCONS provides FM-X5 information covering aerated concrete applications.

For this substrate, establish:

► Exact fixing configuration
► Hole-preparation requirements
► Embedment
► Fixture thickness
► Installation method
► Applicable technical information

Do not transfer capacities or installation assumptions between different base materials without supporting documentation.

Match Screw Material & Finish to the Required Configuration

Not every FM-X5 variant uses the same screw material or protective finish.

Depending on configuration, the documented family includes zinc, galvanised & selected 316 stainless steel options.

Before ordering, consider:

► Installation environment
► Required screw material or finish
► Head style
► Fixing length
► Base material
► Project specification

Confirm the exact product rather than assuming that a finish available on one FM-X5 version applies across the complete range.

Set the Frame Before Final Tightening

A frame fixing is there to secure the chosen position, not establish alignment by force.

Before tightening, check:

► Level
► Plumb
► Alignment
► Required clearances
► Packing locations
► Fixing position

If packers sit behind the frame or profile, make sure they remain correctly positioned as the fixing seats.

Movement during tightening should be addressed rather than accepted as part of the installation.

Stop When the Fixing Is Correctly Seated

Additional torque after seating can damage the drive, fixture or fixing arrangement rather than improve it.

Use the drive corresponding with the selected head & follow the applicable installation requirements.

Pay attention to:

► Head seating
► Fixture movement
► Plug rotation
► Drive-recess condition
► Distortion around the fixing point

Unexpected behaviour can indicate an issue with the hole, substrate, fixing selection or installation.

For further practical context, read Why Good Fasteners Matter More Than the Tool You Drive Them With.

Keep Light-Duty Frame Fixing Separate From Structural Anchoring

FM-X5 is documented as a plastic anchor for light-duty, non-structural applications.

That distinction becomes important where the same project also contains structural concrete connections.

Do not substitute a nylon frame fixing for an engineered anchor simply because both products can be installed into concrete or masonry.

Connections involving structural requirements should use the fixing system nominated for that duty.

For adjoining structural hardware, browse  Structural Fasteners & Bolts.

Treat Fire Classification in Its Documented Application

FM-X5 fire-performance information needs to remain connected to the application for which it is documented.

ICCONS technical information identifies an F90 fire resistance classification with the fire rating stated as valid for façade applications only.

Where fire performance forms part of the project requirements, confirm:

► Exact FM-X5 variant
► Base material
► Façade application
► Installation arrangement
► Current supporting documentation

Do not extend a documented façade classification to unrelated installations without supporting information.

Plan Repetitive Frame Fixing Before Drilling Starts

A long run of profiles becomes easier to manage when fixing lengths, head styles & drilling equipment have already been matched to the work.

Before starting repetitive installation, establish:

► Substrate
► Fixture thickness
► FM-X5 length
► Head configuration
► Required finish
► Drill bit
► Driving equipment
► Set-out positions

For associated threaded fastening requirements elsewhere in the assembly, Bolts & Fasteners provides a broader hardware range.

Keeping the fixing configuration consistent with the actual assembly reduces unnecessary changes once installation is underway.