► ICCONS® | Mixer Nozzles

Consistent Two-Part Adhesive Mixing for Chemical Anchoring The adhesive can be correct, the hole can be prepared correctly & the anchor can be specified correctly—but the two cartridge components still need to be properly blended before injection. ICCONS® | Mixer Nozzles are disposable static-mixing accessories designed to combine compatible Chemselect...

Consistent Two-Part Adhesive Mixing for Chemical Anchoring

The adhesive can be correct, the hole can be prepared correctly & the anchor can be specified correctly—but the two cartridge components still need to be properly blended before injection. ICCONS® | Mixer Nozzles are disposable static-mixing accessories designed to combine compatible Chemselect adhesive components as they move from the cartridge towards the fixing hole.

Choosing the nozzle starts with the adhesive cartridge, not with which mixer looks similar. ICCONS® provides different configurations for particular adhesive families, helping installers pair the dispensing component with the chemical anchoring system being used.

For the closest related installation requirements, explore Adhesives & Tapes, Drill Accessories & Specialty Fasteners & Fixings.

What Are ICCONS® Mixer Nozzles?

A two-component chemical anchor keeps its reactive materials separate inside the cartridge until dispensing begins. A compatible static mixer brings those components together through its internal mixing elements before the adhesive exits the nozzle.

ICCONS® mixer nozzles are thread-on, thread-off disposable accessories for compatible Chemselect adhesive systems. Available configurations include:

► CNOZ10-HP – High Performance Mixer Nozzle for BIS-HY GEN2, BIS-PE GEN3 & BIS-E, supplied as a 10 pack
► CNOZ10-PE – Mixer Nozzle for BIS-E, supplied as a 10 pack with an extension nozzle
► CNOZ10-V – Mixer Nozzle for BIS-V Vinylester & BIS-P Polyester, supplied as a 10 pack
► CNOZEXTN – 1.0 metre plastic extension for adhesive nozzles

Similar appearance doesn't establish compatibility. The cartridge chemistry & product generation determine the mixer required, so check the adhesive designation before fitting a replacement nozzle.

Why Choose ICCONS® Mixer Nozzles?

Mix Both Components During Dispensing

Static mixing removes the need to manually combine the two cartridge components before injection. As the materials travel through the compatible mixer, its internal geometry repeatedly divides & recombines them before the adhesive reaches the outlet.

The resulting mixture can then be delivered into the prepared fixing location according to the adhesive installation procedure.

Maintain the Intended Adhesive Blend

Correct proportions inside the cartridge only help when both components are successfully mixed during dispensing. Using the mixer nominated for the adhesive helps produce the blend required for the material to develop its intended curing characteristics.

A nozzle that merely attaches to the cartridge shouldn't be assumed to perform the same function.

Replace a Used Mixer Without Discarding Usable Adhesive

Work interruptions can leave cured adhesive inside a mixer while usable material remains inside the cartridge. The disposable thread-on/thread-off format allows an appropriate replacement mixer to be fitted when work resumes, subject to the adhesive manufacturer's instructions.

Keeping spare compatible mixers with each cartridge system can prevent a small consumable from interrupting a larger anchoring job.

Extend Adhesive Delivery Where Required

Deep injection positions can create a reach problem even when the adhesive has already been mixed correctly. CNOZEXTN provides a 1 metre plastic extension for adhesive nozzles where the applicable installation procedure requires additional delivery length.

The extension changes the reach of the dispensing arrangement; it doesn't replace the compatible static mixer.

Common Applications

Threaded-Rod Chemical Anchoring

Threaded rod disappears into the fixing hole, but the adhesive surrounding it remains an important part of the connection. Mixer nozzles prepare compatible two-component adhesive immediately before injection around the nominated threaded anchor.

For associated threaded hardware used elsewhere across construction & maintenance projects, browse Bolts & Fasteners.

Concrete Anchor Installation

Good injection work begins with a correctly prepared hole. Drill diameter, depth, cleaning procedure, adhesive selection & anchor geometry all need to correspond with the specified chemical anchoring arrangement.

Where concrete or masonry drilling forms part of the installation, Concrete Cutting & Drilling Tools provides related equipment for preparing fixing locations.

Structural Connections

High-demand connections require every specified component to perform its intended role. Chemical anchors can form part of structural work, retrofit installations, equipment fixing & other applications where dispensing components need to correspond with the selected adhesive.

For conventional high-demand fastening elsewhere within these projects, Structural Fasteners & Bolts provides related structural hardware.

Hollow-Masonry Chemical Anchoring

Hollow masonry introduces a different challenge after the adhesive leaves the mixer. While the nozzle blends the cartridge components, a suitable sleeve may be required to contain adhesive around the fixing rather than allowing material to escape into a cavity.

The mixer, adhesive, sleeve & anchor each perform a separate function within that installation.

Deeper Injection Work

Additional hole depth can change how adhesive needs to be delivered. CNOZEXTN provides extra reach where the applicable chemical anchoring procedure calls for a nozzle extension.

Depending on anchor size, orientation & depth, other injection accessories such as piston plugs may also form part of the required installation method.

Product Selection Guide

Turn the cartridge around & identify the adhesive family before opening a mixer pack. That check is more reliable than trying to distinguish compatible nozzles by colour, length or thread alone.

Part Number

Compatible Adhesive

Format

Intended Role

CNOZ10-HP

BIS-HY GEN2, BIS-PE GEN3 & BIS-E

10 pack

High-performance static mixing

CNOZ10-PE

BIS-E

10 pack with extension nozzle

BIS-E mixing with supplied extension

CNOZ10-V

BIS-V Vinylester & BIS-P Polyester

10 pack

Static mixing for compatible vinylester & polyester adhesives

CNOZEXTN

Compatible adhesive nozzles

1 m extension

Additional injection reach where required

BIS-HY GEN2 on the Cartridge?

Select CNOZ10-HP for BIS-HY GEN2. This High Performance Mixer Nozzle is also identified for BIS-PE GEN3 & BIS-E.

Shared compatibility across those products doesn't make CNOZ10-HP suitable for every Chemselect adhesive.

Working with BIS-PE GEN3?

Product generation matters when consumables from different periods are stored together. BIS-PE GEN3 applications use CNOZ10-HP, so identify the actual cartridge generation rather than relying on an older workshop reference.

This becomes particularly important when replacement nozzles are purchased separately from the adhesive.

Dispensing BIS-E?

BIS-E has more than one mixer reference. CNOZ10-HP is identified as compatible with BIS-E, while CNOZ10-PE is specifically listed for BIS-E & is supplied with an extension nozzle.

Choose according to the cartridge & installation requirements rather than assuming the two packs are identical.

Using BIS-V Vinylester or BIS-P Polyester?

These adhesive families require CNOZ10-V. The nozzle is identified for BIS-V Vinylester & BIS-P Polyester, separating it from the CNOZ10-HP configuration.

Checking the adhesive designation before fitting the mixer is particularly valuable when several Chemselect products are being used on the same project.

Is CNOZEXTN Another Mixer?

No. CNOZEXTN extends the delivery path rather than performing the primary static-mixing function. It provides a 1 metre plastic extension for compatible adhesive nozzles where additional reach is required.

Always establish mixer compatibility first.

Expert Tips

Match the Nozzle Before Dispensing Begins

Compatibility is easiest to correct before adhesive is moving through the cartridge. Read the product designation, identify the corresponding ICCONS® mixer & keep the correct replacement pack with that adhesive system.

Check the Initial Material Leaving a Fresh Mixer

The first adhesive leaving a newly installed static mixer deserves attention. Follow the applicable adhesive instructions for dispensing initial material until the required consistent mix is achieved before injecting into the prepared anchor hole.

Don't use uncertain initial material for the fixing.

Set Out Fixing Positions Before Starting the Cartridge

Once injection begins, working time becomes part of the installation sequence. Establish the fixing locations & complete the required drilling preparation before unnecessarily starting adhesive dispensing.

Measuring & Leveling Tools can assist where multiple anchor positions need to be transferred or aligned before drilling.

For broader guidance on selecting fastening components around different connections, see the Fastener Guide Bolts Screws Anchors.

Don't Treat a Matching Thread as Proof of Compatibility

A nozzle screwing onto a cartridge doesn't establish that its internal mixer is appropriate for the adhesive chemistry. Use the mixer nominated for the actual Chemselect product.

This matters particularly when several cartridges & replacement nozzle packs are stored in the same vehicle, workshop or site container.

Replace a Cured Mixer

Additional trigger pressure isn't the correct response to hardened adhesive inside a disposable mixer. If adhesive has cured within the nozzle, follow the cartridge instructions for removing the used mixer & fitting a fresh compatible replacement.

Don't cut away or modify the internal mixing elements to reopen a blocked nozzle.

Prepare Enough Replacement Mixers for the Work Sequence

A cartridge can still contain usable adhesive while becoming temporarily unusable because the last compatible mixer has cured. Consider the number of cartridges, expected work interruptions & installation stages when preparing replacement consumables.

For practical equipment & consumable planning before larger jobs, read Spring Jobsite Prep Getting Your Gear Ready.

Consider Every Component Between Cartridge & Anchor

Correctly mixed adhesive is only one part of a successful chemical fixing. Hole preparation, injection technique, anchor geometry, substrate conditions & curing requirements all remain important after material exits the nozzle.

For further practical perspective on the complete fastening arrangement, read Why Good Fasteners Matter More Than the Tool You Drive Them With.

Why Buy ICCONS® Mixer Nozzles From Industrial Shed?

A replacement mixer may be a small consumable, but not having the correct one available can interrupt an entire chemical anchoring sequence. Industrial Shed supports builders, concrete contractors, installers, maintenance crews & trade buyers sourcing ICCONS® adhesive accessories alongside their wider fastening requirements.

Part-number ordering becomes particularly useful when several adhesive products are kept in the same workshop or site vehicle. CNOZ10-HP, CNOZ10-PE, CNOZ10-V & CNOZEXTN give purchasing teams clear references for separating compatible consumables before they reach the installer.

For assistance matching chemical-anchor components to an installation requirement, Trade support Solutions provides a direct pathway for product & trade enquiries.

When qualifying stocked replacement consumables are needed for upcoming work, review Same day dispatch for current dispatch arrangements.

Get the Mix Right Before It Reaches the Fixing

The prepared anchor hole isn't the place to discover that the wrong mixer has been fitted. Identify the adhesive, select its compatible static mixer & confirm the material leaving the nozzle is properly blended before beginning injection.

Keeping replacement mixers with their corresponding cartridges also makes changeovers simpler during interrupted work. When a used nozzle has cured, crews can identify the correct replacement without confusing one Chemselect adhesive family with another.

Use the ICCONS® mixer specified for the adhesive cartridge & add CNOZEXTN only where the installation requires additional delivery reach.

Frequently Asked Questions

What happens inside a chemical-anchor mixer nozzle?

Static mixing elements repeatedly combine the separate cartridge components as they pass through the nozzle, preparing the compatible adhesive for injection.

Which nozzle suits BIS-HY GEN2?

CNOZ10-HP is identified for BIS-HY GEN2. It is supplied as a 10 pack & is also compatible with BIS-PE GEN3 & BIS-E.

Which mixer is used with BIS-V Vinylester?

CNOZ10-V is the mixer configuration for BIS-V Vinylester & BIS-P Polyester.

Why are two mixer references associated with BIS-E?

BIS-E is compatible with CNOZ10-HP, while CNOZ10-PE is also specifically listed for BIS-E & is supplied with an extension nozzle. Select the configuration appropriate to the cartridge & installation.

Is the 1 metre CNOZEXTN a static mixer?

No. CNOZEXTN is a plastic nozzle extension that provides additional delivery reach. The appropriate mixer nozzle is still required for the adhesive cartridge.

What should be done when adhesive cures inside a mixer?

Follow the adhesive-system instructions, remove the used disposable mixer & fit a new compatible nozzle. Don't remove or modify the internal mixing elements to force material through a cured mixer.

Brands

► ICCONS® | Mixer Nozzles

Consistent Two-Part Adhesive Mixing for Chemical Anchoring

The adhesive can be correct, the hole can be prepared correctly & the anchor can be specified correctly—but the two cartridge components still need to be properly blended before injection. ICCONS® | Mixer Nozzles are disposable static-mixing accessories designed to combine compatible Chemselect adhesive components as they move from the cartridge towards the fixing hole.

Choosing the nozzle starts with the adhesive cartridge, not with which mixer looks similar. ICCONS® provides different configurations for particular adhesive families, helping installers pair the dispensing component with the chemical anchoring system being used.

For the closest related installation requirements, explore Adhesives & Tapes, Drill Accessories & Specialty Fasteners & Fixings.

What Are ICCONS® Mixer Nozzles?

A two-component chemical anchor keeps its reactive materials separate inside the cartridge until dispensing begins. A compatible static mixer brings those components together through its internal mixing elements before the adhesive exits the nozzle.

ICCONS® mixer nozzles are thread-on, thread-off disposable accessories for compatible Chemselect adhesive systems. Available configurations include:

► CNOZ10-HP – High Performance Mixer Nozzle for BIS-HY GEN2, BIS-PE GEN3 & BIS-E, supplied as a 10 pack
► CNOZ10-PE – Mixer Nozzle for BIS-E, supplied as a 10 pack with an extension nozzle
► CNOZ10-V – Mixer Nozzle for BIS-V Vinylester & BIS-P Polyester, supplied as a 10 pack
► CNOZEXTN – 1.0 metre plastic extension for adhesive nozzles

Similar appearance doesn't establish compatibility. The cartridge chemistry & product generation determine the mixer required, so check the adhesive designation before fitting a replacement nozzle.

Why Choose ICCONS® Mixer Nozzles?

Mix Both Components During Dispensing

Static mixing removes the need to manually combine the two cartridge components before injection. As the materials travel through the compatible mixer, its internal geometry repeatedly divides & recombines them before the adhesive reaches the outlet.

The resulting mixture can then be delivered into the prepared fixing location according to the adhesive installation procedure.

Maintain the Intended Adhesive Blend

Correct proportions inside the cartridge only help when both components are successfully mixed during dispensing. Using the mixer nominated for the adhesive helps produce the blend required for the material to develop its intended curing characteristics.

A nozzle that merely attaches to the cartridge shouldn't be assumed to perform the same function.

Replace a Used Mixer Without Discarding Usable Adhesive

Work interruptions can leave cured adhesive inside a mixer while usable material remains inside the cartridge. The disposable thread-on/thread-off format allows an appropriate replacement mixer to be fitted when work resumes, subject to the adhesive manufacturer's instructions.

Keeping spare compatible mixers with each cartridge system can prevent a small consumable from interrupting a larger anchoring job.

Extend Adhesive Delivery Where Required

Deep injection positions can create a reach problem even when the adhesive has already been mixed correctly. CNOZEXTN provides a 1 metre plastic extension for adhesive nozzles where the applicable installation procedure requires additional delivery length.

The extension changes the reach of the dispensing arrangement; it doesn't replace the compatible static mixer.

Common Applications

Threaded-Rod Chemical Anchoring

Threaded rod disappears into the fixing hole, but the adhesive surrounding it remains an important part of the connection. Mixer nozzles prepare compatible two-component adhesive immediately before injection around the nominated threaded anchor.

For associated threaded hardware used elsewhere across construction & maintenance projects, browse Bolts & Fasteners.

Concrete Anchor Installation

Good injection work begins with a correctly prepared hole. Drill diameter, depth, cleaning procedure, adhesive selection & anchor geometry all need to correspond with the specified chemical anchoring arrangement.

Where concrete or masonry drilling forms part of the installation, Concrete Cutting & Drilling Tools provides related equipment for preparing fixing locations.

Structural Connections

High-demand connections require every specified component to perform its intended role. Chemical anchors can form part of structural work, retrofit installations, equipment fixing & other applications where dispensing components need to correspond with the selected adhesive.

For conventional high-demand fastening elsewhere within these projects, Structural Fasteners & Bolts provides related structural hardware.

Hollow-Masonry Chemical Anchoring

Hollow masonry introduces a different challenge after the adhesive leaves the mixer. While the nozzle blends the cartridge components, a suitable sleeve may be required to contain adhesive around the fixing rather than allowing material to escape into a cavity.

The mixer, adhesive, sleeve & anchor each perform a separate function within that installation.

Deeper Injection Work

Additional hole depth can change how adhesive needs to be delivered. CNOZEXTN provides extra reach where the applicable chemical anchoring procedure calls for a nozzle extension.

Depending on anchor size, orientation & depth, other injection accessories such as piston plugs may also form part of the required installation method.

Product Selection Guide

Turn the cartridge around & identify the adhesive family before opening a mixer pack. That check is more reliable than trying to distinguish compatible nozzles by colour, length or thread alone.

Part Number

Compatible Adhesive

Format

Intended Role

CNOZ10-HP

BIS-HY GEN2, BIS-PE GEN3 & BIS-E

10 pack

High-performance static mixing

CNOZ10-PE

BIS-E

10 pack with extension nozzle

BIS-E mixing with supplied extension

CNOZ10-V

BIS-V Vinylester & BIS-P Polyester

10 pack

Static mixing for compatible vinylester & polyester adhesives

CNOZEXTN

Compatible adhesive nozzles

1 m extension

Additional injection reach where required

BIS-HY GEN2 on the Cartridge?

Select CNOZ10-HP for BIS-HY GEN2. This High Performance Mixer Nozzle is also identified for BIS-PE GEN3 & BIS-E.

Shared compatibility across those products doesn't make CNOZ10-HP suitable for every Chemselect adhesive.

Working with BIS-PE GEN3?

Product generation matters when consumables from different periods are stored together. BIS-PE GEN3 applications use CNOZ10-HP, so identify the actual cartridge generation rather than relying on an older workshop reference.

This becomes particularly important when replacement nozzles are purchased separately from the adhesive.

Dispensing BIS-E?

BIS-E has more than one mixer reference. CNOZ10-HP is identified as compatible with BIS-E, while CNOZ10-PE is specifically listed for BIS-E & is supplied with an extension nozzle.

Choose according to the cartridge & installation requirements rather than assuming the two packs are identical.

Using BIS-V Vinylester or BIS-P Polyester?

These adhesive families require CNOZ10-V. The nozzle is identified for BIS-V Vinylester & BIS-P Polyester, separating it from the CNOZ10-HP configuration.

Checking the adhesive designation before fitting the mixer is particularly valuable when several Chemselect products are being used on the same project.

Is CNOZEXTN Another Mixer?

No. CNOZEXTN extends the delivery path rather than performing the primary static-mixing function. It provides a 1 metre plastic extension for compatible adhesive nozzles where additional reach is required.

Always establish mixer compatibility first.

Expert Tips

Match the Nozzle Before Dispensing Begins

Compatibility is easiest to correct before adhesive is moving through the cartridge. Read the product designation, identify the corresponding ICCONS® mixer & keep the correct replacement pack with that adhesive system.

Check the Initial Material Leaving a Fresh Mixer

The first adhesive leaving a newly installed static mixer deserves attention. Follow the applicable adhesive instructions for dispensing initial material until the required consistent mix is achieved before injecting into the prepared anchor hole.

Don't use uncertain initial material for the fixing.

Set Out Fixing Positions Before Starting the Cartridge

Once injection begins, working time becomes part of the installation sequence. Establish the fixing locations & complete the required drilling preparation before unnecessarily starting adhesive dispensing.

Measuring & Leveling Tools can assist where multiple anchor positions need to be transferred or aligned before drilling.

For broader guidance on selecting fastening components around different connections, see the Fastener Guide Bolts Screws Anchors.

Don't Treat a Matching Thread as Proof of Compatibility

A nozzle screwing onto a cartridge doesn't establish that its internal mixer is appropriate for the adhesive chemistry. Use the mixer nominated for the actual Chemselect product.

This matters particularly when several cartridges & replacement nozzle packs are stored in the same vehicle, workshop or site container.

Replace a Cured Mixer

Additional trigger pressure isn't the correct response to hardened adhesive inside a disposable mixer. If adhesive has cured within the nozzle, follow the cartridge instructions for removing the used mixer & fitting a fresh compatible replacement.

Don't cut away or modify the internal mixing elements to reopen a blocked nozzle.

Prepare Enough Replacement Mixers for the Work Sequence

A cartridge can still contain usable adhesive while becoming temporarily unusable because the last compatible mixer has cured. Consider the number of cartridges, expected work interruptions & installation stages when preparing replacement consumables.

For practical equipment & consumable planning before larger jobs, read Spring Jobsite Prep Getting Your Gear Ready.

Consider Every Component Between Cartridge & Anchor

Correctly mixed adhesive is only one part of a successful chemical fixing. Hole preparation, injection technique, anchor geometry, substrate conditions & curing requirements all remain important after material exits the nozzle.

For further practical perspective on the complete fastening arrangement, read Why Good Fasteners Matter More Than the Tool You Drive Them With.