► ICCONS® | Gas Tools & Fuel Cells

Direct Fastening for Concrete, Steel & Site Installation Need to complete repeated concrete or steel fixings without drilling every suitable connection? ICCONS® | Gas Tools & Fuel Cells bring together gas-powered fastening equipment, compatible fuel cells, collated pins & application-specific consumables for construction, fit-out, formwork, services & insulation installation. Builders,...

Direct Fastening for Concrete, Steel & Site Installation

Need to complete repeated concrete or steel fixings without drilling every suitable connection? ICCONS® | Gas Tools & Fuel Cells bring together gas-powered fastening equipment, compatible fuel cells, collated pins & application-specific consumables for construction, fit-out, formwork, services & insulation installation.

Builders, formworkers, carpenters, fit-out contractors, service installers & maintenance crews can use ICCONS gas-fastening systems across a range of direct-fixing tasks. Tool model, fuel cell, pin family, fixture & substrate need to be matched before work begins. For surrounding equipment requirements, browse Power Tool Accessories, prepare alternative drilled connections with Concrete Cutting & Drilling Tools or compare Screws & Anchors where another fastening method better suits the connection.

► Gas-powered direct-fastening equipment
► Compatible ICCONS fuel cells
► Collated pin & fuel-cell combinations
► Standard pins for suitable concrete & steel
► Ballistic-point options for hard concrete applications
► GT-3, GT-6 & C5-compatible consumable families
► GT-9 concrete nailing system
► Dedicated insulation gas-fastening equipment
► Compatible clips, washers & service-fixing accessories
► Systems for repetitive construction & installation work

What Are ICCONS® Gas Tools & Fuel Cells?

Gas fastening gives crews a direct way to install compatible pins into suitable base materials using a purpose-built gas tool.

The system combines the tool, battery-powered ignition, compatible fuel cell & selected fastener. During the applicable firing sequence, fuel is introduced into the combustion chamber then ignited to drive the piston & install the fastener.

This approach can suit repetitive applications where direct fastening is appropriate.

Typical ICCONS gas-fastening applications include:

► Concrete nailing
► Steel fixing
► Timber or battens to suitable concrete or blockwork
► Track & framing installation
► Formwork
► Service fixing
► Insulation-panel installation
► Compatible clips & accessories

For practical background on selecting fasteners around different connections, read the Fastener Guide Bolts Screws Anchors.

Choose the Gas System Around the Application

A timber fixing, service clip & insulation panel can require different equipment even when each installation uses gas-powered fastening.

Start by identifying the work.

Application

What to Confirm

Repeated concrete or steel fixing

Compatible gas tool, pin & fuel system

Timber or battens to concrete/blockwork

Appropriate concrete-nailing system

Hard concrete

Compatible ballistic-point pin family

Insulation panels

Dedicated insulation tool & suitable insulation fastener

Service clips

Fixture, adaptor & tool compatibility

Specified anchor connection

Appropriate alternative fastening method

Selecting the system from the application helps keep the tool, fuel & fastener working as a compatible combination.

Repetitive Fixing Is Where Gas Tools Become Particularly Useful

Long runs make every extra handling step noticeable.

Where direct fastening suits the connection, a gas tool can reduce repeated drilling & separate anchor installation.

That can be useful when:

► Similar fixing points repeat
► Crews are moving through longer runs
► Suitable concrete or steel is being fastened into
► Compatible collated pins are available
► Manual drilling would add another operation at every point
► The correct consumables can remain with the tool

Accurate set-out still comes first.

Fast cycling provides little benefit if the fixture is incorrectly positioned before the first pin is driven.

Treat the Fuel Cell as Part of the Tool Setup

Similar-looking fuel cells should never be assumed to fit the same equipment.

ICCONS fuel configurations are supplied for particular gas-tool families, including applicable GT-3, GT-6, C5, GT-9 & insulation-tool systems.

Before loading or ordering fuel, check:

► Gas-tool model
► Fuel-cell identification
► Required valve or adaptor where applicable
► Pin family
► Intended application
► Current equipment requirements

Keep the fuel-cell identification available after cartons are opened.

That makes it much easier for crews to confirm compatibility before loading the tool.

Extreme Fuel Is Built for Changing Site Conditions

Cold mornings, hot sheds & humid work areas can place very different demands on gas-powered equipment.

ICCONS Extreme Fuel is designed for compatible ICCONS gas concrete nailers & carries a documented shelf life exceeding 24 months.

The fuel is designed to operate at temperatures down to -10°C, with its mixture also intended for hot & humid conditions.

Storage, handling & equipment compatibility should still follow the applicable manufacturer instructions.

Check the specific fuel-cell configuration before placing it with a tool.


Standard Pins & Hard-Concrete Pins Serve Different Conditions

Concrete hardness can change the consumable requirement even when the fixture itself stays the same.

ICCONS provides standard collated gas pins for suitable concrete & steel applications plus ballistic-point configurations for hard concrete.

Before selecting the pin family, check:

► Base material
► Concrete condition
► Fixture
► Required pin length
► Tool model
► Compatible fuel cell
► Applicable consumable family

Hard-concrete pins should be selected because the installation requires them rather than simply because a standard fixing produced an unexpected result.

Investigate the complete connection before changing consumables.

Pin & Fuel Packs Can Simplify Consumable Preparation

Keeping compatible pins & fuel together can prevent one missing consumable from holding up an otherwise prepared tool.

ICCONS offers pin & fuel combinations for applicable gas-tool families.

Depending on the configuration, these packs combine collated pins with the corresponding fuel cell for the intended system.

GT-3 & GT-6 standard configurations use 10 collated pins per strip for suitable concrete & steel fastening applications.

Before ordering quantity, confirm:

► Tool family
► Pin length
► Pin type
► Fuel compatibility
► Substrate
► Fixture

A combined pack makes preparation easier only when every component suits the equipment being used.

GT-6 Standard Pins Cover Several Fixing Lengths

Fixture thickness is one reason the same gas tool may need different pins during a project.

Documented GT-6 standard pin & fuel configurations include:

Configuration

Pin Length

Suitable Base

GT6-20

20 mm

Suitable concrete & steel

GT6-25

25 mm

Suitable concrete & steel

GT6-35

35 mm

Suitable concrete & steel

Select the pin according to the fixture, base material & applicable system requirements.

Avoid defaulting to the longest available option when a different length belongs with the connection.

For less conventional fixing requirements,  Specialty Fasteners & Fixings provides additional fastening options to consider.

The GT-9 Is Designed for Longer Nailing Runs

Fewer reload interruptions can make a noticeable difference when fixing positions continue across an extended work area.

The ICCONS GT-9 concrete nailer uses a 40-pin track.

Documented applications include:

► Direct fixing timber frame to concrete or block
► Residential construction
► Commercial construction
► Formwork

The system also incorporates automatic piston return & a noise-reduced design.

For suitable repetitive timber or batten fixing, the larger magazine capacity can reduce stops between loading cycles.

Mark the Fixing Positions Before Filling the Magazine

A fast fastening cycle works best after the route, centres & clearances have already been established.

Before beginning a repetitive run, confirm:

► Fixture line
► Fixing centres
► Corners
► Openings
► Equipment positions
► Substrate changes
► Service clearances
► Obstructions

For longer installations, Measuring & Layout Tools can assist with consistent positioning.

Complete the set-out first then use the gas system to move efficiently through suitable fixing points.

Hard Concrete Calls for a Fresh Assessment

Repeated difficulty seating a pin can indicate that something within the connection has changed.

Check:

► Base material
► Concrete condition
► Pin family
► Pin condition
► Tool setup
► Fuel cell
► Fixture
► Applicable equipment requirements

ICCONS offers ballistic-point gas pins for compatible hard-concrete applications.

Confirm the appropriate consumable before continuing rather than repeatedly attempting the same unsuitable setup.

Compare Direct Fastening With a Drilled Anchor

The correct method depends on the connection, not simply the material visible behind the fixture.

Gas fastening can suit compatible repetitive direct-fixing work.

A drilled anchor may be appropriate where:

► The connection is specified for an anchor
► Direct fastening does not suit the substrate
► A threaded removable connection is required
► Fixture geometry requires another fixing method
► The design calls for an engineered anchor
► Access prevents suitable gas-tool operation

For applicable conventional concrete connections, compare  Anchor Bolts.

Use the fastening method specified or appropriate for the installation.

Service Fixings Extend Beyond Standard Pins

Pipework, cables & other building services can require purpose-built attachments rather than a bare pin against the fixture.

Compatible gas-fastening accessories can include:

► Conduit saddles
► Cable-tie mounts
► Metal angle clips
► Steel washers
► Pipe-support components
► Insulation fasteners

Check each specialised fixing as a complete assembly.

Tool family, adaptor, fastener & fixture all need to suit one another before installation begins.

Insulation Panels Need Their Own Fastening Setup

Panel thickness changes the selection process before the tool reaches the wall or ceiling.

Dedicated ICCONS gas insulation systems are intended for compatible insulation-panel applications.

Selection can depend on:

► Insulation thickness
► Fastener length
► Barrel configuration
► Base material
► Panel requirements
► Required fixing pattern

Match the fastener to the actual panel thickness & substrate.

Where the insulation manufacturer specifies fixing quantities, locations or patterns, follow those requirements across the installation.

Look After the Tool Before Performance Starts Changing

Regular cleaning & inspection are easier than troubleshooting equipment in the middle of a fixing run.

Watch for:

► Inconsistent cycling
► Poor pin feeding
► Difficulty starting
► Irregular combustion
► Magazine damage
► Worn nose components
► Unexpected fixing results

Follow the applicable cleaning & maintenance instructions for the tool.

For practical guidance around dependable equipment, read A tool is not just a tool. It’s a promise..

If the Tool Stops Cycling, Check the Whole System

Fuel is only one possible cause when a gas tool stops operating consistently.

Work through the setup methodically.

Battery

Is the battery charged, serviceable & correctly installed?

Fuel Cell

Is the correct compatible fuel cell fitted?

Pins

Is the intended collated-pin family loaded correctly?

Magazine

Are the pins feeding freely?

Tool

Is the nose assembly clean & operating correctly?

Fixture

Has the material or thickness changed?

Substrate

Has the work moved into harder concrete, steel or another base condition?

Checking the complete system can identify a simple mismatch before good consumables are unnecessarily replaced.

Separate Fuel Cells & Pin Families Before They Reach Site

Consumable identification becomes increasingly important when several gas tools are operating from the same workshop or vehicle.

Organise stock by:

► Tool family
► Fuel-cell part number
► Pin family
► Standard or hard-concrete configuration
► Pin length
► Work zone
► Application where useful

Avoid mixing unidentified fuel cells or loose pin strips in one container.

Keep original product identification with the consumables wherever practical.

Inspect the First Fixings Before Increasing the Work Rate

The opening section of a run shows whether the selected tool, pin, fuel, fixture & substrate are working together as expected.

Check:

► Pin seating
► Fixture position
► Material condition
► Penetration
► Substrate behaviour
► Feed consistency
► Tool cycling

Stop if results become inconsistent.

For crews preparing tools & consumables before larger installation stages, Spring Jobsite Prep Getting Your Gear Ready provides further practical preparation guidance.

Know When Another Fastening Method Is Required

Gas tools are productive when the connection suits direct fastening but they should not be forced into unsuitable work.

Choose another method where:

► The substrate does not suit the system
► Project documentation requires another connection
► A removable fixing is required
► Tool access is restricted
► Fixture geometry prevents appropriate direct fastening
► The connection requires another fastening system

For applications requiring conventional threaded connections, Structural Fasteners & Bolts provides a different fastening family.

Match the method to the work rather than altering the work to suit the tool.

Keep Each Gas Setup Identifiable

A clear tool-and-consumable combination reduces uncertainty when equipment is shared between crews.

Record or organise by:

► Tool model
► Fuel-cell type
► Pin family
► Pin length
► Standard or hard-concrete configuration
► Intended fixture
► Work area

Where several ICCONS gas tools are operating on one project, keep each setup together where practical.

This makes it easier to identify the correct consumables when tools move between work zones.

Why Source ICCONS® Gas Tools & Fuel Cells Through Industrial Shed?

Keeping compatible fuel, pins & equipment together helps prevent an avoidable consumable mismatch from interrupting site work.

Industrial Shed supports builders, formworkers, fit-out contractors, carpenters, service installers & maintenance teams sourcing gas-fastening equipment & consumables.

When regularly used fastening equipment needs inspection or fault diagnosis, Power Tool Repairs & Diagnostics provides dedicated equipment support.

Need help confirming which consumables belong with a particular gas tool? Contact Us with the tool model, substrate, fixture & intended application.

Match the Fuel, Pin & Tool Before Work Begins

Reliable gas fastening depends on every component belonging to the same installation.

Identify the substrate & fixture then select the compatible tool, fuel cell, pin family & accessories. Keep standard & hard-concrete consumables separated, retain clear product identification & inspect the first completed fixings before progressing through a longer run.

Whenever the fixture, substrate or tool changes, confirm the setup again before loading the next strip.

Choose ICCONS Gas Tools & Fuel Cells for compatible direct fastening where the tool, fuel, pin, fixture & substrate have been correctly matched for the work.

Frequently Asked Questions

Can the same ICCONS fuel cell be used in every ICCONS gas tool?

No. Fuel-cell configurations vary between tool families. Confirm the tool model, compatible fuel-cell configuration & any required valve or adaptor.

What's the difference between standard & hard-concrete gas pins?

Standard collated pins are intended for documented concrete & steel applications while compatible hard-concrete families use ballistic-point configurations for harder base materials.

How many pins are in a GT-6 collated strip?

Documented GT-6 standard configurations use 10 collated pins per strip.

Which standard GT-6 pin lengths are available?

Documented GT-6 standard pin & fuel configurations include 20 mm, 25 mm & 35 mm lengths.

Why would we choose a GT-9 for repetitive concrete nailing?

The GT-9 uses a 40-pin track, reducing reload frequency across suitable repetitive applications such as timber frame to concrete or blockwork & formwork.

Can ICCONS gas tools be used for insulation panels?

ICCONS has dedicated gas insulation systems for compatible panel applications. Fastener length & setup need to suit the insulation thickness, substrate & panel requirements.

Brands

► ICCONS® | Gas Tools & Fuel Cells

Direct Fastening for Concrete, Steel & Site Installation

Need to complete repeated concrete or steel fixings without drilling every suitable connection? ICCONS® | Gas Tools & Fuel Cells bring together gas-powered fastening equipment, compatible fuel cells, collated pins & application-specific consumables for construction, fit-out, formwork, services & insulation installation.

Builders, formworkers, carpenters, fit-out contractors, service installers & maintenance crews can use ICCONS gas-fastening systems across a range of direct-fixing tasks. Tool model, fuel cell, pin family, fixture & substrate need to be matched before work begins. For surrounding equipment requirements, browse Power Tool Accessories, prepare alternative drilled connections with Concrete Cutting & Drilling Tools or compare Screws & Anchors where another fastening method better suits the connection.

► Gas-powered direct-fastening equipment
► Compatible ICCONS fuel cells
► Collated pin & fuel-cell combinations
► Standard pins for suitable concrete & steel
► Ballistic-point options for hard concrete applications
► GT-3, GT-6 & C5-compatible consumable families
► GT-9 concrete nailing system
► Dedicated insulation gas-fastening equipment
► Compatible clips, washers & service-fixing accessories
► Systems for repetitive construction & installation work

What Are ICCONS® Gas Tools & Fuel Cells?

Gas fastening gives crews a direct way to install compatible pins into suitable base materials using a purpose-built gas tool.

The system combines the tool, battery-powered ignition, compatible fuel cell & selected fastener. During the applicable firing sequence, fuel is introduced into the combustion chamber then ignited to drive the piston & install the fastener.

This approach can suit repetitive applications where direct fastening is appropriate.

Typical ICCONS gas-fastening applications include:

► Concrete nailing
► Steel fixing
► Timber or battens to suitable concrete or blockwork
► Track & framing installation
► Formwork
► Service fixing
► Insulation-panel installation
► Compatible clips & accessories

For practical background on selecting fasteners around different connections, read the Fastener Guide Bolts Screws Anchors.

Choose the Gas System Around the Application

A timber fixing, service clip & insulation panel can require different equipment even when each installation uses gas-powered fastening.

Start by identifying the work.

Application

What to Confirm

Repeated concrete or steel fixing

Compatible gas tool, pin & fuel system

Timber or battens to concrete/blockwork

Appropriate concrete-nailing system

Hard concrete

Compatible ballistic-point pin family

Insulation panels

Dedicated insulation tool & suitable insulation fastener

Service clips

Fixture, adaptor & tool compatibility

Specified anchor connection

Appropriate alternative fastening method

Selecting the system from the application helps keep the tool, fuel & fastener working as a compatible combination.

Repetitive Fixing Is Where Gas Tools Become Particularly Useful

Long runs make every extra handling step noticeable.

Where direct fastening suits the connection, a gas tool can reduce repeated drilling & separate anchor installation.

That can be useful when:

► Similar fixing points repeat
► Crews are moving through longer runs
► Suitable concrete or steel is being fastened into
► Compatible collated pins are available
► Manual drilling would add another operation at every point
► The correct consumables can remain with the tool

Accurate set-out still comes first.

Fast cycling provides little benefit if the fixture is incorrectly positioned before the first pin is driven.

Treat the Fuel Cell as Part of the Tool Setup

Similar-looking fuel cells should never be assumed to fit the same equipment.

ICCONS fuel configurations are supplied for particular gas-tool families, including applicable GT-3, GT-6, C5, GT-9 & insulation-tool systems.

Before loading or ordering fuel, check:

► Gas-tool model
► Fuel-cell identification
► Required valve or adaptor where applicable
► Pin family
► Intended application
► Current equipment requirements

Keep the fuel-cell identification available after cartons are opened.

That makes it much easier for crews to confirm compatibility before loading the tool.

Extreme Fuel Is Built for Changing Site Conditions

Cold mornings, hot sheds & humid work areas can place very different demands on gas-powered equipment.

ICCONS Extreme Fuel is designed for compatible ICCONS gas concrete nailers & carries a documented shelf life exceeding 24 months.

The fuel is designed to operate at temperatures down to -10°C, with its mixture also intended for hot & humid conditions.

Storage, handling & equipment compatibility should still follow the applicable manufacturer instructions.

Check the specific fuel-cell configuration before placing it with a tool.


Standard Pins & Hard-Concrete Pins Serve Different Conditions

Concrete hardness can change the consumable requirement even when the fixture itself stays the same.

ICCONS provides standard collated gas pins for suitable concrete & steel applications plus ballistic-point configurations for hard concrete.

Before selecting the pin family, check:

► Base material
► Concrete condition
► Fixture
► Required pin length
► Tool model
► Compatible fuel cell
► Applicable consumable family

Hard-concrete pins should be selected because the installation requires them rather than simply because a standard fixing produced an unexpected result.

Investigate the complete connection before changing consumables.

Pin & Fuel Packs Can Simplify Consumable Preparation

Keeping compatible pins & fuel together can prevent one missing consumable from holding up an otherwise prepared tool.

ICCONS offers pin & fuel combinations for applicable gas-tool families.

Depending on the configuration, these packs combine collated pins with the corresponding fuel cell for the intended system.

GT-3 & GT-6 standard configurations use 10 collated pins per strip for suitable concrete & steel fastening applications.

Before ordering quantity, confirm:

► Tool family
► Pin length
► Pin type
► Fuel compatibility
► Substrate
► Fixture

A combined pack makes preparation easier only when every component suits the equipment being used.

GT-6 Standard Pins Cover Several Fixing Lengths

Fixture thickness is one reason the same gas tool may need different pins during a project.

Documented GT-6 standard pin & fuel configurations include:

Configuration

Pin Length

Suitable Base

GT6-20

20 mm

Suitable concrete & steel

GT6-25

25 mm

Suitable concrete & steel

GT6-35

35 mm

Suitable concrete & steel

Select the pin according to the fixture, base material & applicable system requirements.

Avoid defaulting to the longest available option when a different length belongs with the connection.

For less conventional fixing requirements,  Specialty Fasteners & Fixings provides additional fastening options to consider.

The GT-9 Is Designed for Longer Nailing Runs

Fewer reload interruptions can make a noticeable difference when fixing positions continue across an extended work area.

The ICCONS GT-9 concrete nailer uses a 40-pin track.

Documented applications include:

► Direct fixing timber frame to concrete or block
► Residential construction
► Commercial construction
► Formwork

The system also incorporates automatic piston return & a noise-reduced design.

For suitable repetitive timber or batten fixing, the larger magazine capacity can reduce stops between loading cycles.

Mark the Fixing Positions Before Filling the Magazine

A fast fastening cycle works best after the route, centres & clearances have already been established.

Before beginning a repetitive run, confirm:

► Fixture line
► Fixing centres
► Corners
► Openings
► Equipment positions
► Substrate changes
► Service clearances
► Obstructions

For longer installations, Measuring & Layout Tools can assist with consistent positioning.

Complete the set-out first then use the gas system to move efficiently through suitable fixing points.

Hard Concrete Calls for a Fresh Assessment

Repeated difficulty seating a pin can indicate that something within the connection has changed.

Check:

► Base material
► Concrete condition
► Pin family
► Pin condition
► Tool setup
► Fuel cell
► Fixture
► Applicable equipment requirements

ICCONS offers ballistic-point gas pins for compatible hard-concrete applications.

Confirm the appropriate consumable before continuing rather than repeatedly attempting the same unsuitable setup.

Compare Direct Fastening With a Drilled Anchor

The correct method depends on the connection, not simply the material visible behind the fixture.

Gas fastening can suit compatible repetitive direct-fixing work.

A drilled anchor may be appropriate where:

► The connection is specified for an anchor
► Direct fastening does not suit the substrate
► A threaded removable connection is required
► Fixture geometry requires another fixing method
► The design calls for an engineered anchor
► Access prevents suitable gas-tool operation

For applicable conventional concrete connections, compare  Anchor Bolts.

Use the fastening method specified or appropriate for the installation.

Service Fixings Extend Beyond Standard Pins

Pipework, cables & other building services can require purpose-built attachments rather than a bare pin against the fixture.

Compatible gas-fastening accessories can include:

► Conduit saddles
► Cable-tie mounts
► Metal angle clips
► Steel washers
► Pipe-support components
► Insulation fasteners

Check each specialised fixing as a complete assembly.

Tool family, adaptor, fastener & fixture all need to suit one another before installation begins.

Insulation Panels Need Their Own Fastening Setup

Panel thickness changes the selection process before the tool reaches the wall or ceiling.

Dedicated ICCONS gas insulation systems are intended for compatible insulation-panel applications.

Selection can depend on:

► Insulation thickness
► Fastener length
► Barrel configuration
► Base material
► Panel requirements
► Required fixing pattern

Match the fastener to the actual panel thickness & substrate.

Where the insulation manufacturer specifies fixing quantities, locations or patterns, follow those requirements across the installation.

Look After the Tool Before Performance Starts Changing

Regular cleaning & inspection are easier than troubleshooting equipment in the middle of a fixing run.

Watch for:

► Inconsistent cycling
► Poor pin feeding
► Difficulty starting
► Irregular combustion
► Magazine damage
► Worn nose components
► Unexpected fixing results

Follow the applicable cleaning & maintenance instructions for the tool.

For practical guidance around dependable equipment, read A tool is not just a tool. It’s a promise..

If the Tool Stops Cycling, Check the Whole System

Fuel is only one possible cause when a gas tool stops operating consistently.

Work through the setup methodically.

Battery

Is the battery charged, serviceable & correctly installed?

Fuel Cell

Is the correct compatible fuel cell fitted?

Pins

Is the intended collated-pin family loaded correctly?

Magazine

Are the pins feeding freely?

Tool

Is the nose assembly clean & operating correctly?

Fixture

Has the material or thickness changed?

Substrate

Has the work moved into harder concrete, steel or another base condition?

Checking the complete system can identify a simple mismatch before good consumables are unnecessarily replaced.

Separate Fuel Cells & Pin Families Before They Reach Site

Consumable identification becomes increasingly important when several gas tools are operating from the same workshop or vehicle.

Organise stock by:

► Tool family
► Fuel-cell part number
► Pin family
► Standard or hard-concrete configuration
► Pin length
► Work zone
► Application where useful

Avoid mixing unidentified fuel cells or loose pin strips in one container.

Keep original product identification with the consumables wherever practical.

Inspect the First Fixings Before Increasing the Work Rate

The opening section of a run shows whether the selected tool, pin, fuel, fixture & substrate are working together as expected.

Check:

► Pin seating
► Fixture position
► Material condition
► Penetration
► Substrate behaviour
► Feed consistency
► Tool cycling

Stop if results become inconsistent.

For crews preparing tools & consumables before larger installation stages, Spring Jobsite Prep Getting Your Gear Ready provides further practical preparation guidance.

Know When Another Fastening Method Is Required

Gas tools are productive when the connection suits direct fastening but they should not be forced into unsuitable work.

Choose another method where:

► The substrate does not suit the system
► Project documentation requires another connection
► A removable fixing is required
► Tool access is restricted
► Fixture geometry prevents appropriate direct fastening
► The connection requires another fastening system

For applications requiring conventional threaded connections, Structural Fasteners & Bolts provides a different fastening family.

Match the method to the work rather than altering the work to suit the tool.

Keep Each Gas Setup Identifiable

A clear tool-and-consumable combination reduces uncertainty when equipment is shared between crews.

Record or organise by:

► Tool model
► Fuel-cell type
► Pin family
► Pin length
► Standard or hard-concrete configuration
► Intended fixture
► Work area

Where several ICCONS gas tools are operating on one project, keep each setup together where practical.

This makes it easier to identify the correct consumables when tools move between work zones.