► Hardie Hose | Test Points

Hydraulic Pressure Access for Smarter Fault Diagnosis The operator says the hydraulics are weak. The pump sounds normal. The machine still moves — but something changes when the system is working hard. Where does the technician look next? Hardie Hose Test Points provide dedicated pressure-access locations for compatible hydraulic systems,...

Hydraulic Pressure Access for Smarter Fault Diagnosis

The operator says the hydraulics are weak. The pump sounds normal. The machine still moves — but something changes when the system is working hard. Where does the technician look next? Hardie Hose Test Points provide dedicated pressure-access locations for compatible hydraulic systems, allowing suitable diagnostic equipment to be connected without unnecessarily opening another working connection.

For earthmoving plant, agricultural machinery, hydraulic workshops & industrial equipment, a correctly selected test point can make repeat pressure checks far more practical. Technicians can return to a known circuit location, reproduce the relevant operating condition & compare what the system is doing over time.

► Dedicated access for compatible hydraulic pressure checks
► Useful during fault diagnosis, servicing & commissioning
► Suitable for mobile plant & industrial hydraulic applications
► Supports repeat measurements from known circuit locations
► Practical for workshop & field-service technicians
► Choose according to connection, system pressure & testing requirements

What Are Hydraulic Test Points?

A hydraulic test point is a dedicated access connection used to take pressure measurements from a suitable hydraulic circuit.

Its role becomes clearer when the diagnostic setup is separated into three parts:

Hydraulic circuit → test point → test hose → pressure gauge

The test point provides access to the circuit.

The test hose carries that pressure to compatible measuring equipment.

The gauge displays the measurement.

From there, the technician interprets the result according to the machine, circuit, operating condition & applicable service information.

A test point doesn't diagnose the machine. It gives the technician somewhere appropriate to collect diagnostic information.

Why Choose Hardie Hose Test Points?

Because Opening a Hydraulic Line Just to Check Pressure Isn't the Ideal Starting Point

Equipment that's regularly serviced benefits from known diagnostic locations.

Instead of treating every pressure check as a new connection problem, an appropriate test point gives technicians a repeatable location for suitable testing equipment.

That can be valuable during:

► Hydraulic troubleshooting
► Circuit pressure checks
► Machine commissioning
► Scheduled servicing
► Post-repair verification
► Fleet maintenance
► Hot-versus-cold comparisons
► Recurring fault investigation

Consider the difference between these two workshop notes:

“Hydraulics tested. Pressure low.”

and:

“Lift circuit tested at designated point after machine reached operating condition.”

The second tells the next technician considerably more about what was actually checked.

Where Do Test Points Earn Their Keep?

Earthmoving Plant – One Function Has Lost Force

An excavator still tracks normally but one attachment function feels noticeably weaker.

Rather than treating the entire hydraulic system as one problem, the technician can identify the affected circuit, locate the appropriate test position & perform the relevant checks according to the machine procedure.

One weak function doesn't automatically mean one obvious failed component.

Agricultural Machinery – The Problem Appears After Lunch

Morning operation is normal.

After several hours of work, the tractor's hydraulic performance changes.

This is exactly the kind of complaint where test conditions matter. A reading taken immediately after cold startup may not reproduce the behaviour the operator has reported.

Materials Handling – Lift Performance Becomes Inconsistent

Forklifts, loaders & other hydraulic lifting equipment can develop symptoms that appear under particular operating conditions.

Known pressure-access locations can help a competent technician gather information from the relevant circuit rather than replacing components from assumption.

Industrial Machinery – Downtime Has a Production Cost

Hydraulic clamps, presses & actuators can be integral to production equipment.

Where appropriate test locations form part of the system, maintenance teams can incorporate them into established troubleshooting & service procedures.

Field Hydraulic Service – “It's Just Not Right”

A mobile technician doesn't always receive a detailed fault report.

The phone call might simply say:

“The hydraulics have gone weak.”

The first job isn't to choose a replacement component. It's to identify the symptom, affected function & appropriate place to begin testing.

Fleet Workshops – Today's Reading Becomes Tomorrow's Reference

Repeated servicing creates something a one-off repair doesn't: history.

Recording measurements from consistent locations under comparable conditions can give workshop teams useful information when the same machine returns months later.

Product Selection Guide

Already Have the Old Test Point? Don't Throw It Away Yet.

The removed component can help identify what the replacement needs to correspond with.

Check the following before selection.

Connection

Identify the required connection accurately from the existing system or applicable equipment information.

Don't force a hydraulic connection that doesn't engage as expected.

System Requirements

Confirm that the test point & complete diagnostic arrangement are suitable for the hydraulic system involved.

Diagnostic Connection

How will the compatible test hose or measuring equipment connect?

The machine side isn't the only interface that matters.

Circuit Location

Know which hydraulic function the test point accesses.

Two pressure-access locations on the same machine may exist for entirely different diagnostic purposes.

Test Conditions

The relevant procedure may require a particular:

► Operating temperature
► Engine or motor speed
► Load condition
► Control position
► Machine state
► Test sequence

Pressure without context is just a number.

What Part of the Pressure-Testing Setup Are You Actually Replacing?

Imagine the technician has the following setup in front of them:

Machine → test point → diagnostic hose → gauge

Now identify where the problem sits.

Situation

Look At

Reason

Circuit has no suitable diagnostic access

Test point arrangement

Provides the pressure-access location

Existing access component is damaged

Test point

Restores the designated connection where appropriate

Gauge can't reach the machine

Compatible test hose/setup

Connects instrument to access point

Reading can't be displayed correctly

Suitable measuring instrument

Provides the pressure indication

Connection won't mate

Compatibility at both interfaces

Identifies where the mismatch occurs

Reading seems wrong

Entire test setup & procedure

Avoids blaming one component prematurely

Don't replace the gauge because the connection is wrong. Don't replace the test point because the instrument is unsuitable. Identify which part of the diagnostic chain needs attention.

A Different Way to Read Hydraulic Symptoms

A symptom can help determine where the next useful question belongs.

What the Operator Reports

Useful Question

Worth Recording

“Everything feels weak.”

Is the issue affecting multiple functions?

Circuits affected & operating condition

“Only the boom is slow.”

Is the issue isolated to that function?

Relevant circuit & test location

“It's fine when cold.”

What changes at operating temperature?

Cold/hot conditions

“It struggles with weight.”

What occurs under the specified load condition?

Load & corresponding measurement

“It started after the repair.”

What changed before the symptom appeared?

Previous work & test result

“It does this every few months.”

Is there a repeatable pattern?

Previous measurements & conditions

This is why a well-documented test location can be more useful than a pressure number written on its own.

Expert Tips From the Diagnostic Side of the Workshop

Give Test Locations Names That Mean Something

“Port 3” isn't particularly helpful if nobody knows what Port 3 accesses.

Where appropriate, equipment records should make relevant test locations identifiable to the technicians using them.

Take the Reading Where the Fault Lives

A complaint that occurs only after sustained operation deserves investigation under the applicable conditions rather than automatically relying on an easy cold check.

Photograph an Unfamiliar Installation Before Removal

A close image of the installed component, surrounding fittings & location can preserve useful information before anything is dismantled.

Keep the Diagnostic Connections Out of the Dirt

Civil plant & farm machinery aren't clean environments.

Protect test connections & diagnostic equipment appropriately so the act of checking the system doesn't introduce avoidable contamination.

Put Context Beside Every Number

Write down the circuit, machine state & relevant conditions with the measurement.

A number separated from its circumstances loses value quickly.

Don't Make the Gauge the Hero

The instrument reports what reaches it.

Unexpected results still need to be considered against the connection, test location, operating procedure & hydraulic circuit.

Build a Machine-Specific Test Record

For frequently serviced equipment, keep previous comparable results against the asset.

Patterns can become much easier to recognise when technicians aren't starting with a blank page each visit.

Workshop Scenario: The Loader Is Strong Cold & Lazy Hot

At 7:00 am, the loader behaves normally.

By mid-morning, the operator reports that lift performance has deteriorated.

A useful investigation isn't simply:

Connect gauge → read pressure → replace suspected component.

Instead, the technician may establish:

Cold behaviour
What does the machine do before the reported problem appears?

Warm behaviour
At what point does performance change?

Affected functions
Is lift alone affected or has something changed elsewhere?

Relevant circuit
Which hydraulic circuit corresponds with the complaint?

Test location
Where does the applicable procedure require pressure to be checked?

Measurement conditions
What machine state is required for a meaningful comparison?

Result
How does the reading relate to the applicable equipment information?

The test point's job is modest but important:

it provides access to the circuit at the place chosen for testing.

Temporary Pressure Access or Continuous Indication?

Not every hydraulic system needs pressure displayed continuously.

A Test Point May Be Appropriate When Pressure Is Checked During:

► Scheduled servicing
► Troubleshooting
► Commissioning
► Field diagnosis
► Post-repair verification
► Periodic condition checks

A Permanently Installed Gauge Serves a Different Purpose

Where equipment is designed for continuous pressure indication, an installed gauge arrangement may be required instead.

One provides diagnostic access when needed. The other can provide ongoing visual indication.

Choose according to the equipment rather than assuming they're interchangeable solutions.

The Test Result Came Back Low. What Now?

Don't Order the Pump Yet.

A low measurement is information about the test performed at that location under those conditions.

Depending on the hydraulic system, further investigation by a competent technician may involve relevant areas such as:

► Pump operation
► Control functions
► Relief functions
► Valves
► Cylinders or actuators
► Hydraulic hoses & connections
► Internal leakage
► Fluid condition
► Operating temperature

The appropriate checks depend on the machine & circuit design.

A single unexpected reading should guide diagnosis rather than become an automatic parts order.

What If the Pressure Looks Correct?

This result can be useful too.

If pressure at the specified location is within the expected range while the machine still performs poorly, the technician has information that may shift attention elsewhere in the investigation.

Hydraulic performance isn't described by one number alone.

Pressure needs to be considered alongside the machine's function, operating conditions & system design.

A Five-Minute Habit That Improves the Next Service Call

Before closing the job, capture the useful details.

Record

Example of What to Keep

Asset

Machine or fleet identifier

Complaint

Reported hydraulic behaviour

Function

Circuit investigated

Access point

Test location used

Machine state

Relevant operating condition

Measurement

Recorded pressure

Reference

Applicable machine information

Outcome

Findings or further work

Date

When the check occurred

Six months later, the next technician can compare something meaningful rather than relying on:

“Pretty sure we checked that last time.”

Hydraulic Cleanliness Doesn't Stop During Diagnosis

Connecting test equipment creates another opportunity for contamination to approach the hydraulic system.

Before & after testing, follow the applicable cleanliness requirements for the equipment involved.

Pay attention to:

► Test-point condition
► Diagnostic connectors
► Test hoses
► Protective caps or covers
► Storage of test equipment
► Dirt around the connection area
► Exposed connections during testing

A pressure check should help diagnose the hydraulic system — not create another maintenance problem.

Preparing a Field Hydraulic Test Kit

A technician working away from the workshop needs more than a pressure gauge thrown into a toolbox.

Depending on the machinery being serviced, organised diagnostic equipment may include suitable:

► Pressure-measuring instruments
► Test hoses
► Diagnostic connections
► Protective components
► Cleaning supplies
► Identification labels
► Machine information
► Service records

Keep equipment identifiable so the technician can deliberately choose what suits the system being checked.

For workshops wanting frequently used service components & consumables organised around recurring work, Industrial Shed's On-Site & Workshop Services can assist with workshop & jobsite supply requirements.

Before Pressure Testing Begins

Hydraulic systems can operate at pressures capable of causing serious injury.

Competent personnel should follow the equipment manufacturer's procedures & appropriate hydraulic safety practices, including confirming that the test equipment is suitable for the system involved.

Before a pressure check, establish:

► Correct test location
► Suitable test-point connection
► Diagnostic equipment compatibility
► Appropriate pressure capability
► Condition of test hoses & connectors
► Required operating procedure
► Cleanliness around the connection

Never use hands or other body parts to search for suspected high-pressure hydraulic leaks.

Why Buy From Industrial Shed?

For hydraulic technicians, access to the circuit is only useful when the component suits the equipment being tested. Industrial Shed supplies Hardie Hose test points for compatible hydraulic applications alongside products used across plant maintenance, workshop servicing & field repairs.

► Hydraulic test points for suitable diagnostic applications
► Components for plant & machinery maintenance
► Options relevant to workshop & mobile service work
► Support for recurring maintenance requirements
► Australian trade-focused supply

If a maintenance job is waiting on parts, check Industrial Shed's Same Day Dispatch information when planning the order.

Before You Blame the Pump, Read the Circuit

Hydraulic faults can sound expensive long before anyone has measured them. A dedicated test point gives a competent technician somewhere to connect suitable diagnostic equipment & investigate what the circuit is actually doing when the reported problem occurs.

For a one-off repair, that measurement can help direct the next check. Across a fleet, repeatable test locations & properly recorded results can become an increasingly useful part of the machine's maintenance history.

Hardie Hose Test Points put a measurement between the symptom & the parts order.

Frequently Asked Questions

The machine has several test points. Which one should I use?

Use the location specified for the hydraulic function & test procedure being investigated. Different ports may access different circuits or sections of the system.

Can a test point stay installed on the machine?

Test points are commonly used as dedicated diagnostic access where the equipment & component arrangement is designed for them. Installation needs to suit the particular hydraulic system.

My pressure is normal cold but changes once the machine is working. Is the test point faulty?

Not necessarily. If the machine's behaviour also changes with temperature, the technician should investigate according to the applicable hot-condition test procedure rather than assuming the access point is responsible.

Why shouldn't I connect whatever gauge is available?

The gauge, hose, connectors & complete testing arrangement need to suit the system pressure & connection requirements. Compatibility should be established before testing.

Do two test points on the same hydraulic circuit always show the same pressure?

Not necessarily. Readings can depend on circuit design, test location & operating conditions. Interpret measurements according to the equipment's hydraulic information.

Is one low reading enough to condemn a hydraulic pump?

No. It provides a diagnostic result from a particular location & condition. Further checks may be necessary before identifying the cause.

Brands

► Hardie Hose | Test Points

Hydraulic Pressure Access for Smarter Fault Diagnosis

The operator says the hydraulics are weak. The pump sounds normal. The machine still moves — but something changes when the system is working hard. Where does the technician look next? Hardie Hose Test Points provide dedicated pressure-access locations for compatible hydraulic systems, allowing suitable diagnostic equipment to be connected without unnecessarily opening another working connection.

For earthmoving plant, agricultural machinery, hydraulic workshops & industrial equipment, a correctly selected test point can make repeat pressure checks far more practical. Technicians can return to a known circuit location, reproduce the relevant operating condition & compare what the system is doing over time.

► Dedicated access for compatible hydraulic pressure checks
► Useful during fault diagnosis, servicing & commissioning
► Suitable for mobile plant & industrial hydraulic applications
► Supports repeat measurements from known circuit locations
► Practical for workshop & field-service technicians
► Choose according to connection, system pressure & testing requirements

What Are Hydraulic Test Points?

A hydraulic test point is a dedicated access connection used to take pressure measurements from a suitable hydraulic circuit.

Its role becomes clearer when the diagnostic setup is separated into three parts:

Hydraulic circuit → test point → test hose → pressure gauge

The test point provides access to the circuit.

The test hose carries that pressure to compatible measuring equipment.

The gauge displays the measurement.

From there, the technician interprets the result according to the machine, circuit, operating condition & applicable service information.

A test point doesn't diagnose the machine. It gives the technician somewhere appropriate to collect diagnostic information.

Why Choose Hardie Hose Test Points?

Because Opening a Hydraulic Line Just to Check Pressure Isn't the Ideal Starting Point

Equipment that's regularly serviced benefits from known diagnostic locations.

Instead of treating every pressure check as a new connection problem, an appropriate test point gives technicians a repeatable location for suitable testing equipment.

That can be valuable during:

► Hydraulic troubleshooting
► Circuit pressure checks
► Machine commissioning
► Scheduled servicing
► Post-repair verification
► Fleet maintenance
► Hot-versus-cold comparisons
► Recurring fault investigation

Consider the difference between these two workshop notes:

“Hydraulics tested. Pressure low.”

and:

“Lift circuit tested at designated point after machine reached operating condition.”

The second tells the next technician considerably more about what was actually checked.

Where Do Test Points Earn Their Keep?

Earthmoving Plant – One Function Has Lost Force

An excavator still tracks normally but one attachment function feels noticeably weaker.

Rather than treating the entire hydraulic system as one problem, the technician can identify the affected circuit, locate the appropriate test position & perform the relevant checks according to the machine procedure.

One weak function doesn't automatically mean one obvious failed component.

Agricultural Machinery – The Problem Appears After Lunch

Morning operation is normal.

After several hours of work, the tractor's hydraulic performance changes.

This is exactly the kind of complaint where test conditions matter. A reading taken immediately after cold startup may not reproduce the behaviour the operator has reported.

Materials Handling – Lift Performance Becomes Inconsistent

Forklifts, loaders & other hydraulic lifting equipment can develop symptoms that appear under particular operating conditions.

Known pressure-access locations can help a competent technician gather information from the relevant circuit rather than replacing components from assumption.

Industrial Machinery – Downtime Has a Production Cost

Hydraulic clamps, presses & actuators can be integral to production equipment.

Where appropriate test locations form part of the system, maintenance teams can incorporate them into established troubleshooting & service procedures.

Field Hydraulic Service – “It's Just Not Right”

A mobile technician doesn't always receive a detailed fault report.

The phone call might simply say:

“The hydraulics have gone weak.”

The first job isn't to choose a replacement component. It's to identify the symptom, affected function & appropriate place to begin testing.

Fleet Workshops – Today's Reading Becomes Tomorrow's Reference

Repeated servicing creates something a one-off repair doesn't: history.

Recording measurements from consistent locations under comparable conditions can give workshop teams useful information when the same machine returns months later.

Product Selection Guide

Already Have the Old Test Point? Don't Throw It Away Yet.

The removed component can help identify what the replacement needs to correspond with.

Check the following before selection.

Connection

Identify the required connection accurately from the existing system or applicable equipment information.

Don't force a hydraulic connection that doesn't engage as expected.

System Requirements

Confirm that the test point & complete diagnostic arrangement are suitable for the hydraulic system involved.

Diagnostic Connection

How will the compatible test hose or measuring equipment connect?

The machine side isn't the only interface that matters.

Circuit Location

Know which hydraulic function the test point accesses.

Two pressure-access locations on the same machine may exist for entirely different diagnostic purposes.

Test Conditions

The relevant procedure may require a particular:

► Operating temperature
► Engine or motor speed
► Load condition
► Control position
► Machine state
► Test sequence

Pressure without context is just a number.

What Part of the Pressure-Testing Setup Are You Actually Replacing?

Imagine the technician has the following setup in front of them:

Machine → test point → diagnostic hose → gauge

Now identify where the problem sits.

Situation

Look At

Reason

Circuit has no suitable diagnostic access

Test point arrangement

Provides the pressure-access location

Existing access component is damaged

Test point

Restores the designated connection where appropriate

Gauge can't reach the machine

Compatible test hose/setup

Connects instrument to access point

Reading can't be displayed correctly

Suitable measuring instrument

Provides the pressure indication

Connection won't mate

Compatibility at both interfaces

Identifies where the mismatch occurs

Reading seems wrong

Entire test setup & procedure

Avoids blaming one component prematurely

Don't replace the gauge because the connection is wrong. Don't replace the test point because the instrument is unsuitable. Identify which part of the diagnostic chain needs attention.

A Different Way to Read Hydraulic Symptoms

A symptom can help determine where the next useful question belongs.

What the Operator Reports

Useful Question

Worth Recording

“Everything feels weak.”

Is the issue affecting multiple functions?

Circuits affected & operating condition

“Only the boom is slow.”

Is the issue isolated to that function?

Relevant circuit & test location

“It's fine when cold.”

What changes at operating temperature?

Cold/hot conditions

“It struggles with weight.”

What occurs under the specified load condition?

Load & corresponding measurement

“It started after the repair.”

What changed before the symptom appeared?

Previous work & test result

“It does this every few months.”

Is there a repeatable pattern?

Previous measurements & conditions

This is why a well-documented test location can be more useful than a pressure number written on its own.

Expert Tips From the Diagnostic Side of the Workshop

Give Test Locations Names That Mean Something

“Port 3” isn't particularly helpful if nobody knows what Port 3 accesses.

Where appropriate, equipment records should make relevant test locations identifiable to the technicians using them.

Take the Reading Where the Fault Lives

A complaint that occurs only after sustained operation deserves investigation under the applicable conditions rather than automatically relying on an easy cold check.

Photograph an Unfamiliar Installation Before Removal

A close image of the installed component, surrounding fittings & location can preserve useful information before anything is dismantled.

Keep the Diagnostic Connections Out of the Dirt

Civil plant & farm machinery aren't clean environments.

Protect test connections & diagnostic equipment appropriately so the act of checking the system doesn't introduce avoidable contamination.

Put Context Beside Every Number

Write down the circuit, machine state & relevant conditions with the measurement.

A number separated from its circumstances loses value quickly.

Don't Make the Gauge the Hero

The instrument reports what reaches it.

Unexpected results still need to be considered against the connection, test location, operating procedure & hydraulic circuit.

Build a Machine-Specific Test Record

For frequently serviced equipment, keep previous comparable results against the asset.

Patterns can become much easier to recognise when technicians aren't starting with a blank page each visit.

Workshop Scenario: The Loader Is Strong Cold & Lazy Hot

At 7:00 am, the loader behaves normally.

By mid-morning, the operator reports that lift performance has deteriorated.

A useful investigation isn't simply:

Connect gauge → read pressure → replace suspected component.

Instead, the technician may establish:

Cold behaviour
What does the machine do before the reported problem appears?

Warm behaviour
At what point does performance change?

Affected functions
Is lift alone affected or has something changed elsewhere?

Relevant circuit
Which hydraulic circuit corresponds with the complaint?

Test location
Where does the applicable procedure require pressure to be checked?

Measurement conditions
What machine state is required for a meaningful comparison?

Result
How does the reading relate to the applicable equipment information?

The test point's job is modest but important:

it provides access to the circuit at the place chosen for testing.

Temporary Pressure Access or Continuous Indication?

Not every hydraulic system needs pressure displayed continuously.

A Test Point May Be Appropriate When Pressure Is Checked During:

► Scheduled servicing
► Troubleshooting
► Commissioning
► Field diagnosis
► Post-repair verification
► Periodic condition checks

A Permanently Installed Gauge Serves a Different Purpose

Where equipment is designed for continuous pressure indication, an installed gauge arrangement may be required instead.

One provides diagnostic access when needed. The other can provide ongoing visual indication.

Choose according to the equipment rather than assuming they're interchangeable solutions.

The Test Result Came Back Low. What Now?

Don't Order the Pump Yet.

A low measurement is information about the test performed at that location under those conditions.

Depending on the hydraulic system, further investigation by a competent technician may involve relevant areas such as:

► Pump operation
► Control functions
► Relief functions
► Valves
► Cylinders or actuators
► Hydraulic hoses & connections
► Internal leakage
► Fluid condition
► Operating temperature

The appropriate checks depend on the machine & circuit design.

A single unexpected reading should guide diagnosis rather than become an automatic parts order.

What If the Pressure Looks Correct?

This result can be useful too.

If pressure at the specified location is within the expected range while the machine still performs poorly, the technician has information that may shift attention elsewhere in the investigation.

Hydraulic performance isn't described by one number alone.

Pressure needs to be considered alongside the machine's function, operating conditions & system design.

A Five-Minute Habit That Improves the Next Service Call

Before closing the job, capture the useful details.

Record

Example of What to Keep

Asset

Machine or fleet identifier

Complaint

Reported hydraulic behaviour

Function

Circuit investigated

Access point

Test location used

Machine state

Relevant operating condition

Measurement

Recorded pressure

Reference

Applicable machine information

Outcome

Findings or further work

Date

When the check occurred

Six months later, the next technician can compare something meaningful rather than relying on:

“Pretty sure we checked that last time.”

Hydraulic Cleanliness Doesn't Stop During Diagnosis

Connecting test equipment creates another opportunity for contamination to approach the hydraulic system.

Before & after testing, follow the applicable cleanliness requirements for the equipment involved.

Pay attention to:

► Test-point condition
► Diagnostic connectors
► Test hoses
► Protective caps or covers
► Storage of test equipment
► Dirt around the connection area
► Exposed connections during testing

A pressure check should help diagnose the hydraulic system — not create another maintenance problem.

Preparing a Field Hydraulic Test Kit

A technician working away from the workshop needs more than a pressure gauge thrown into a toolbox.

Depending on the machinery being serviced, organised diagnostic equipment may include suitable:

► Pressure-measuring instruments
► Test hoses
► Diagnostic connections
► Protective components
► Cleaning supplies
► Identification labels
► Machine information
► Service records

Keep equipment identifiable so the technician can deliberately choose what suits the system being checked.

For workshops wanting frequently used service components & consumables organised around recurring work, Industrial Shed's On-Site & Workshop Services can assist with workshop & jobsite supply requirements.

Before Pressure Testing Begins

Hydraulic systems can operate at pressures capable of causing serious injury.

Competent personnel should follow the equipment manufacturer's procedures & appropriate hydraulic safety practices, including confirming that the test equipment is suitable for the system involved.

Before a pressure check, establish:

► Correct test location
► Suitable test-point connection
► Diagnostic equipment compatibility
► Appropriate pressure capability
► Condition of test hoses & connectors
► Required operating procedure
► Cleanliness around the connection

Never use hands or other body parts to search for suspected high-pressure hydraulic leaks.