{"title":"► ICCONS® | Beam Clamps \u0026 Rizes","description":"\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003e Suspend Building Services from Steel Beams Without Drilling\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cstrong\u003eHow do you establish a threaded-rod suspension point beneath structural steel without drilling through the beam flange?\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eICCONS® Beam Clamps provide a mechanical attachment method for suitable steel beams, giving installers an M10 or M12 hanger point for suspended building services.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFor HVAC, pipework, fire services, cable support \u0026amp; other overhead installations, that distinction matters. The clamp attaches to the beam flange rather than relying on a drilled connection, while its through-hole arrangement allows subsequent adjustment of the suspended level.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBefore quantities are ordered, confirm the beam geometry, rod diameter \u0026amp; support requirements. Related hardware can be found across\u003c\/span\u003e\u003ca href=\"https:\/\/www.industrialshed.net.au\/collections\/specialty-fasteners-fixings\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eSpecialty Fasteners \u0026amp; Fixings\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e,\u003c\/span\u003e\u003ca href=\"https:\/\/www.industrialshed.net.au\/collections\/bolts-fasteners\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eBolts \u0026amp; Fasteners\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e \u0026amp;\u003c\/span\u003e\u003ca href=\"https:\/\/www.industrialshed.net.au\/collections\/structural-fasteners-bolts\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eStructural Fasteners \u0026amp; Bolts\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWhat Are ICCONS® Beam Clamps \u0026amp; Rizes?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBeam clamps turn an accessible steel flange into a threaded-rod suspension point. Instead of creating a hole through the structural member, the clamp engages with a suitable flange \u0026amp; provides the connection needed for the hanger assembly below.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe current ICCONS® Beam Clamp range includes:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e► TKN10 – M10 Beam Clamp with up to 20 mm clamp depth \u0026amp; an 11 mm clearance hole\u003c\/span\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cspan\u003e► TK12 – M12 Beam Clamp with up to 26 mm clamp depth \u0026amp; a 13 mm clearance hole\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBoth configurations have a zinc finish \u0026amp; are designed for suitable parallel or tapered flange beams.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eM10 versus M12 is only one part of the decision. The proposed attachment point also needs to suit the clamp geometry, supported service, required capacity \u0026amp; project documentation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eWhy Choose ICCONS® Beam Clamps \u0026amp; Rizes?\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eEstablish a Hanger Point Without Drilling the Flange\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eStructural steel shouldn't be modified simply because a suspension point is needed underneath it. Where a beam-clamp connection is appropriate, the ICCONS® design provides an attachment method that avoids drilling through the flange.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThis can simplify installation while preserving the beam from an unnecessary site-made hole.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eAccommodate Different Flange Profiles\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eA tapered flange presents a different contact geometry from a parallel flange. ICCONS® specifies these Beam Clamps for both configurations, provided the actual flange dimensions suit the selected clamp.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eChecking the steel at the intended attachment position is therefore more useful than selecting from the beam name alone.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eMake Final Level Adjustments\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMechanical, hydraulic \u0026amp; electrical services often need fine adjustment once the supporting components are in position. ICCONS® identifies later level adjustment through the clamp's through-hole as a feature of the system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThat can assist when bringing suspended services into the required elevation after the initial hanger points have been established.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eUse Reinforced Suspension Hardware\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSmall overhead components can carry substantial responsibility within a service-support assembly. ICCONS® incorporates a reinforcement rib into its Beam Clamp design \u0026amp; identifies high load-bearing capacity as a product feature.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eActual allowable loads must be taken from the relevant technical information \u0026amp; complete support design rather than estimated from the clamp's physical size.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eAccount for Approval Requirements\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFire-protection hardware may need more than dimensional compatibility. ICCONS® identifies FM \u0026amp; VdS approval certifications for its Beam Clamp range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWhere certification forms part of the project specification, confirm that the exact clamp \u0026amp; complete installation satisfy those requirements before substitution or installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eCommon Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eHVAC Suspension\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eDuctwork often has to find its level beneath steel long before ceilings conceal the support system. Beam clamps can provide attachment points for compatible threaded-rod arrangements supporting ductwork \u0026amp; associated mechanical services.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eRepeated hanger positions can be established with\u003c\/span\u003e\u003ca href=\"https:\/\/www.industrialshed.net.au\/collections\/measuring-leveling-tools\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eMeasuring \u0026amp; Leveling Tools\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e before the services are lifted into place.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003ePipe \u0026amp; Hydraulic Services\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eA pipe support is only as coordinated as the hardware above it. Rod diameter, hanger spacing, service weight, clamp position \u0026amp; beam geometry all need to form a compatible suspension arrangement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eBeam clamps address the steel-flange connection where this attachment method is permitted by the installation design.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eFire-Protection Installations\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eSprinkler infrastructure brings its own support \u0026amp; approval considerations. The FM \u0026amp; VdS certifications identified by ICCONS® make the Beam Clamp range relevant where approved suspension hardware is required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCertification of the clamp should not be interpreted as automatic approval of every rod, bracket, pipe support or installation arrangement connected to it.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eElectrical Containment\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCable tray, ladder \u0026amp; associated containment systems can create long runs of repeated suspension points. Attaching threaded rod from suitable steel flanges allows those services to be supported below the structure without drilling each flange.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eEarly coordination becomes particularly valuable where electrical containment shares overhead space with ductwork, pipework \u0026amp; fire services.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eMulti-Service Commercial Fit-Out\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOne beam can sit above several different trades, each working to a different elevation. Planning hanger locations before installation helps keep suspension points organised \u0026amp; reduces avoidable interference between services.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFor larger layouts,\u003c\/span\u003e\u003ca href=\"https:\/\/www.industrialshed.net.au\/collections\/surveying-layout-tools\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eSurveying \u0026amp; Layout Tools\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e can assist with transferring repeated positions across the work area.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eProduct Selection Guide\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003ePut the tape measure on the flange before deciding between TKN10 \u0026amp; TK12. The rod connection matters, but so does the thickness of steel the clamp needs to accommodate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv dir=\"ltr\" align=\"left\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"123\"\u003e\n\u003ccol width=\"126\"\u003e\n\u003ccol width=\"182\"\u003e\n\u003ccol width=\"120\"\u003e\n\u003ccol width=\"58\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eICCONS® Part\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eRod Connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMaximum Clamp Depth\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eClearance Hole\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFinish\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTKN10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eM10\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e20 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e11 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eZinc\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTK12\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eM12\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e26 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e13 mm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eZinc\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWhere TKN10 Fits?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAn M10 suspension design points towards TKN10, provided the beam flange also falls within its dimensional requirements. The clamp accommodates up to 20 mm depth \u0026amp; incorporates an 11 mm clearance hole.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCheck the support design before ordering simply on the basis that M10 rod is already available on site.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWhere TK12 Fits?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWhen the documented hanger arrangement calls for M12 threaded rod, TK12 provides the corresponding beam-clamp configuration. It accommodates up to 26 mm clamp depth with a 13 mm clearance hole.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIts larger dimensions shouldn't be used as a reason to substitute it into an installation that was designed around different hardware.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eBeam Clamp or Steel Hanger Fixing?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTwo suspension methods can reach a similar outcome while making completely different connections to the structure. A beam clamp grips a suitable flange. Other steel hanger fixings may attach directly into an appropriate steel substrate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe decision depends on the available steel section, attachment position, support design, rod requirement \u0026amp; applicable documentation—not whichever product is faster to install.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eWhat if the Support Point Is Concrete?\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eMove from steel to concrete \u0026amp; the fixing method changes with the substrate. A beam clamp isn't intended to replace a concrete rod hanger, mechanical anchor or chemical anchoring system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWhere the supporting structure requires a different anchoring method,\u003c\/span\u003e\u003ca href=\"https:\/\/www.industrialshed.net.au\/collections\/anchor-bolts\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eAnchor Bolts\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e provides a related pathway for suitable applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eExpert Tips\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eInspect the Exact Attachment Position\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFlange dimensions can determine suitability before rod size ever becomes relevant. Measure where the clamp will actually sit \u0026amp; check for geometry, coatings, obstructions or other conditions that could affect correct engagement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTKN10 accommodates up to 20 mm clamp depth, while TK12 accommodates up to 26 mm.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eCoordinate the Ceiling Space Before Hardware Goes Up\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eOverhead congestion is easier to solve on a drawing or set-out than between installed hangers. Consider ductwork, pipes, cable containment, sprinkler services \u0026amp; access requirements before establishing long rows of suspension points.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThis becomes increasingly important where several contractors share the same structural bays.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eKeep M10 \u0026amp; M12 Assemblies Separate\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eA mixed container of hanger components creates unnecessary uncertainty during installation. Store TKN10 \u0026amp; TK12 clamps with their corresponding rod hardware so crews can identify the specified assembly without sorting components at height.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003ca href=\"https:\/\/www.industrialshed.net.au\/collections\/fasteners-hardware-supplies\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003eNuts \u0026amp; Washers\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e covers related threaded fastening hardware used across workshop \u0026amp; construction requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eRead the Capacity Data, Not the Thread Marking\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAn M12 connection isn't a shorthand load rating. The clamp, beam geometry, threaded rod, associated support hardware \u0026amp; suspended service all contribute to the completed arrangement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eWhere loading is critical, work from the applicable technical information \u0026amp; project requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eVerify Certification Before a Fire-Service Installation\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eAn approval requirement should be resolved during procurement rather than discovered during inspection. ICCONS® identifies FM \u0026amp; VdS certifications for the Beam Clamp range, but the nominated product \u0026amp; complete support arrangement still need to correspond with the project specification.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eRecord the required product identification where traceability forms part of the job.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eCheck Seating Before Loading the Hanger\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCorrect engagement with the flange is fundamental to the clamp's function. Make sure the hardware is positioned \u0026amp; installed in accordance with ICCONS® requirements before the threaded-rod assembly is loaded.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eA partially seated clamp or unsuitable flange condition shouldn't be accepted simply because the rod hangs vertically.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\"\u003e\u003cspan\u003eReview the Entire Suspension Assembly\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe beam clamp is only the upper connection. Threaded rod, nuts, washers, brackets, pipe supports or other suspended components need to form a compatible arrangement below it.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eFor further practical context on selecting fastening hardware around the connection itself, read\u003c\/span\u003e\u003ca href=\"https:\/\/www.industrialshed.net.au\/blogs\/why-good-fasteners-matter-more-than-the-tool-you-drive-them-with\/why-good-fasteners-matter-more-than-the-tool-you-drive-them-with\" target=\"_blank\" rel=\"noopener\"\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eWhy Good Fasteners Matter More Than the Tool You Drive Them With\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e","products":[],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0869\/4562\/8449\/collections\/Iccons-Industrial-Shed-Somerville_c736a951-e608-4359-8a1c-b4262eedf59f.jpg?v=1757998273","url":"https:\/\/www.industrialshed.net.au\/collections\/iccons-beam-clamps-rizes.oembed","provider":"Industrial Shed","version":"1.0","type":"link"}